Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools

medtronic

Source -

NVD

BOS Name -

N/A

CNA CVEs -

0

ADP CVEs -

0

CISA CVEs -

0

NVD CVEs -

25
Related CVEsRelated ProductsRelated AssignersReports
25Vulnerabilities found

CVE-2023-31222
Assigner-Medtronic
ShareView Details
Assigner-Medtronic
CVSS Score-9.8||CRITICAL
EPSS-28.53% / 96.36%
||
7 Day CHG~0.00%
Published-29 Jun, 2023 | 15:19
Updated-26 Nov, 2024 | 19:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Paceart MSMQ Deserialization of Untrusted Data

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.

Action-Not Available
Vendor-medtronicMedtronic
Product-paceart_optimaPaceart Optima
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2023-25931
Assigner-Medtronic
ShareView Details
Assigner-Medtronic
CVSS Score-6.4||MEDIUM
EPSS-0.11% / 30.91%
||
7 Day CHG~0.00%
Published-01 Mar, 2023 | 18:56
Updated-07 Mar, 2025 | 21:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Micro Clinician & InterStim X Clinician App Password Reset Issue

Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix. Not updating could potentially result in unauthorized control of the clinician therapy application, which has greater control over therapy parameters than the patient app. Changes still cannot be made outside of the established therapy parameters of the programmer. For unauthorized access to occur, an individual would need physical access to the Smart Programmer.

Action-Not Available
Vendor-medtronicMedtronic
Product-micro_clinicianinterstim_x_clinicianInsterStim Applications
CWE ID-CWE-620
Unverified Password Change
CWE ID-CWE-287
Improper Authentication
CVE-2022-32537
Assigner-Medtronic
ShareView Details
Assigner-Medtronic
CVSS Score-4.8||MEDIUM
EPSS-0.05% / 15.58%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 20:47
Updated-29 Apr, 2025 | 14:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MiniMed 600 Series Pump System Communication Issue

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance

Action-Not Available
Vendor-medtronicMedtronic
Product-guardian_link_2_transmitter_mmt-7738_firmwareminimed_620g_mmt-1750minimed_630g_mmt-1755minimed_670g_mmt-1782_firmwareminimed_640g_mmt-1751_firmwaremmt-1151minimed_630g_mmt-1755_firmwareminimed_630g_mmt-1715_firmwareminimed_670g_mmt-1741mmt-1352guardian_link_2_transmitter_mmt-7730_firmwareminimed_670g_mmt-1761_firmwareminimed_670g_mmt-1760minimed_640g_mmt-1712minimed_640g_mmt-1751minimed_670g_mmt-1741_firmwareminimed_630g_mmt-1754mmt-1352_firmwareguardian_link_3_transmitter_mmt-7811minimed_670g_mmt-1740mmt-1351minimed_670g_mmt-1762_firmwareminimed_670g_mmt-1740_firmwareguardian_link_2_transmitter_mmt-7775minimed_670g_mmt-1780_firmwareminimed_670g_mmt-1782guardian_link_2_transmitter_mmt-7738minimed_670g_mmt-1760_firmwareminimed_640g_mmt-1711_firmwareminimed_670g_mmt-1762mmt-1152_firmwaremmt-1351_firmwareminimed_670g_mmt-1780mmt-1152minimed_640g_mmt-1752_firmwareguardian_link_2_transmitter_mmt-7730guardian_link_2_transmitter_mmt-7775_firmwareminimed_670g_mmt-1761minimed_640g_mmt-1711guardian_link_3_transmitter_mmt-7811_firmwareminimed_670g_mmt-1742minimed_670g_mmt-1781_firmwareminimed_630g_mmt-1715minimed_640g_mmt-1752mmt-1151_firmwareguardian_link_3_transmitter_mmt-7810minimed_640g_mmt-1712_firmwareminimed_670g_mmt-1742_firmwaremmt-7306minimed_620g_mmt-1750_firmwaremmt-7306_firmwareguardian_link_2_transmitter_mmt-7731_firmwareguardian_link_3_transmitter_mmt-7810_firmwareminimed_630g_mmt-1754_firmwareminimed_670g_mmt-1781guardian_link_2_transmitter_mmt-7731Minimed 600 Series Insulin Pump
CWE ID-CWE-693
Protection Mechanism Failure
CVE-2020-27252
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.65%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:19
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink Smart Time-of-check Time-of-use Race Condition

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device.

Action-Not Available
Vendor-medtronicMedtronic
Product-mycarelink_smart_model_25000_firmwaremycarelink_smart_model_25000Smart Model 25000 Patient Reader
CWE ID-CWE-367
Time-of-check Time-of-use (TOCTOU) Race Condition
CVE-2020-25187
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.90% / 74.72%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:18
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink Smart Heap-based Buffer Overflow

Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device

Action-Not Available
Vendor-medtronicMedtronic
Product-mycarelink_smart_model_25000_firmwaremycarelink_smart_model_25000Smart Model 25000 Patient Reader
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-25183
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8||HIGH
EPSS-0.14% / 35.22%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:18
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink Smart Improper Authentication

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.

Action-Not Available
Vendor-medtronicMedtronic
Product-mycarelink_smart_model_25000_firmwaremycarelink_smart_model_25000Smart Model 25000 Patient Reader
CWE ID-CWE-287
Improper Authentication
CVE-2019-13531
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.8||MEDIUM
EPSS-0.13% / 33.82%
||
7 Day CHG~0.00%
Published-08 Nov, 2019 | 19:46
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Valleylab FT10 and LS10 Improper Authentication

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator.

Action-Not Available
Vendor-medtronicMedtronic
Product-valleylab_ft10_energy_platformvalleylab_ls10_energy_platformvalleylab_ls10_energy_platform_firmwarevalleylab_ft10_energy_platform_firmwareValleylab FT10 Energy Platform (VLFT10GEN)Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States)
CWE ID-CWE-287
Improper Authentication
CVE-2019-13535
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.6||MEDIUM
EPSS-0.45% / 62.67%
||
7 Day CHG~0.00%
Published-08 Nov, 2019 | 19:45
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Valleylab FT10 and LS10 Protection Mechanism Failure

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.

Action-Not Available
Vendor-medtronicMedtronic
Product-valleylab_ft10_energy_platformvalleylab_ls10_energy_platformvalleylab_ls10_energy_platform_firmwarevalleylab_ft10_energy_platform_firmwareValleylab FT10 Energy Platform (VLFT10GEN)Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States)
CWE ID-CWE-693
Protection Mechanism Failure
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2019-13539
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7||HIGH
EPSS-0.21% / 43.85%
||
7 Day CHG~0.00%
Published-08 Nov, 2019 | 19:07
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Valleylab FT10 and FX8 Reversible One-way Hash

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.

Action-Not Available
Vendor-medtronicMedtronic
Product-valleylab_ft10_energy_platformvalleylab_ft10_energy_platform_firmwarevalleylab_fx8_energy_platformvalleylab_exchange_clientvalleylab_fx8_energy_platform_firmwareValleylab FX8 Energy Platform (VLFX8GEN)Valleylab Exchange ClientValleylab FT10 Energy Platform (VLFT10GEN)
CWE ID-CWE-328
Use of Weak Hash
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2019-13543
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.8||MEDIUM
EPSS-0.66% / 70.32%
||
7 Day CHG~0.00%
Published-08 Nov, 2019 | 19:03
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Valleylab FT10 and FX8 Use of Hard-coded Credentials

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.

Action-Not Available
Vendor-medtronicMedtronic
Product-valleylab_ft10_energy_platformvalleylab_ft10_energy_platform_firmwarevalleylab_fx8_energy_platformvalleylab_exchange_clientvalleylab_fx8_energy_platform_firmwareValleylab FX8 Energy Platform (VLFX8GEN)Valleylab Exchange ClientValleylab FT10 Energy Platform (VLFT10GEN)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-10964
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.1||HIGH
EPSS-0.45% / 62.81%
||
7 Day CHG~0.00%
Published-28 Jun, 2019 | 20:58
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

Action-Not Available
Vendor-medtronicMedtronic
Product-minimed_paradigm_722minimed_paradigm_512minimed_paradigm_veo_554minimed_paradigm_523kminimed_paradigm_veo_754cmminimed_paradigm_723k_firmwareminimed_paradigm_veo_754cm_firmwareminimed_paradigm_712e_firmwareminimed_paradigm_523minimed_paradigm_veo_554cmminimed_paradigm_511minimed_paradigm_723minimed_paradigm_722_firmwareminimed_paradigm_712eminimed_paradigm_723_firmwareminimed_paradigm_522k_firmwareminimed_paradigm_veo_754minimed_paradigm_715_firmwareminimed_paradigm_723kminimed_508_firmwareminimed_paradigm_715minimed_paradigm_veo_754_firmwareminimed_paradigm_523k_firmwareminimed_paradigm_512_firmwareminimed_paradigm_523_firmwareminimed_paradigm_veo_554_firmwareminimed_paradigm_712_firmwareminimed_paradigm_veo_554cm_firmwareminimed_paradigm_522minimed_paradigm_722kminimed_508minimed_paradigm_722k_firmwareminimed_paradigm_515minimed_paradigm_511_firmwareminimed_paradigm_712minimed_paradigm_515_firmwareminimed_paradigm_522kminimed_paradigm_522_firmwareMiniMed Paradigm 512/712 pumpsMiniMed 508 pumpMiniMed Paradigm 515/715 pumpsMiniMed Paradigm 511 pumpMiniMed Paradigm 522K/722K pumpsMiniMed Paradigm 523/723 pumpsMiniMed Paradigm 523K/723K pumpsMiniMed Paradigm 522/722 pumpsMiniMed Paradigm Veo 554/754 pumpsMiniMed Paradigm Veo 554CM/754CM pumpsMiniMed Paradigm 712E pump
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6540
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.02% / 3.00%
||
7 Day CHG~0.00%
Published-26 Mar, 2019 | 17:47
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Conexus Radio Frequency Telemetry Protocol Cleartext Transmission of Sensitive Information

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

Action-Not Available
Vendor-medtronicMedtronic
Product-carelink_monitor_2490cvirtuoso_ii_icdvirtuoso_ii_icd_firmwaremaximo_ii_crt-dcompia_crt-dvisia_af_icd_firmwarecarelink_monitor_2490c_firmwareclaria_crt-d_firmwareevera_icd_firmwaremaximo_ii_crt-d_firmwarenayamed_nd_icdmirro_icd_firmwarecarelink_2090_firmwareprotecta_crt-dprimo_icd_firmwareconsulta_crt-d_firmwaresecura_icdviva_crt-d_firmwarenayamed_nd_icd_firmwarevirtuoso_icdmirro_icdconcerto_ii_crt-d_firmwareconcerto_crt-d_firmwaremycarelink_monitor_24952_firmwareprotecta_icdvirtuoso_icd_firmwarevisia_af_icdconcerto_ii_crt-devera_icdcarelink_2090concerto_crt-dmaximo_ii_icdamplia_crt-dclaria_crt-dmaximo_ii_icd_firmwareprimo_icdmycarelink_monitor_24950consulta_crt-damplia_crt-d_firmwareprotecta_crt-d_firmwaremycarelink_monitor_24952mycarelink_monitor_24950_firmwareprotecta_icd_firmwarecompia_crt-d_firmwareviva_crt-dsecura_icd_firmwareMirro ICDViva CRT-DEvera ICDVirtuoso II ICDAmplia CRT-DNayamed ND ICDClaria CRT-DMirro MRI ICDCareLink MonitorMyCareLink MonitorMaximo II ICDSecura ICDVirtuoso ICDConcerto CRT-DProtecta ICD, Protecta CRT-DCompia CRT-DMaximo II CRT-DVisia AF ICDConcerto II CRT-DCareLink 2090 ProgrammerPrimo ICDConsulta CRT-DConexus Radio Frequency Telemetry ProtocolBrava CRT-D
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2019-6538
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.3||CRITICAL
EPSS-0.28% / 50.78%
||
7 Day CHG~0.00%
Published-25 Mar, 2019 | 21:26
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

Action-Not Available
Vendor-medtronicMedtronic
Product-virtuoso_ii_icdvirtuoso_ii_icd_firmwarecompia_crt-dvisia_af_icd_firmwareclaria_crt-d_firmwareevera_icd_firmwarenayamed_nd_icdmaximo_ii_crt-d_and_lcdmirro_icd_firmwarecarelink_2090_firmwaremycarelink_monitor_firmwareprimo_icd_firmwareconsulta_crt-d_firmwaresecura_icdviva_crt-d_firmwarenayamed_nd_icd_firmwarecarelink_monitormirro_icdvirtuoso_icdconcerto_ii_crt-d_firmwareconcerto_crt-d_firmwaremycarelink_monitorvirtuoso_icd_firmwarevisia_af_icdconcerto_ii_crt-devera_icdcarelink_2090concerto_crt-damplia_crt-dclaria_crt-dmaximo_ii_crt-d_and_lcd_firmwarecarelink_monitor_firmwareprimo_icdprotecta_icd_and_crt-dconsulta_crt-damplia_crt-d_firmwareprotecta_icd_and_crt-d_firmwarecompia_crt-d_firmwareviva_crt-dsecura_icd_firmwareMirro ICDViva CRT-DEvera ICDVirtuoso II ICDAmplia CRT-DNayamed ND ICDClaria CRT-DMirro MRI ICDCareLink MonitorMyCareLink MonitorMaximo II ICDSecura ICDVirtuoso ICDConcerto CRT-DProtecta ICD, Protecta CRT-DCompia CRT-DMaximo II CRT-DVisia AF ICDConcerto II CRT-DCareLink 2090 ProgrammerPrimo ICDConsulta CRT-DConexus Radio Frequency Telemetry ProtocolBrava CRT-D
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-862
Missing Authorization
CVE-2018-18984
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.6||MEDIUM
EPSS-0.10% / 28.90%
||
7 Day CHG~0.00%
Published-14 Dec, 2018 | 15:00
Updated-22 May, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic 9790, 2090 CareLink, and 29901 Encore Programmers Missing Encryption of Sensitive Data

Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest .

Action-Not Available
Vendor-medtronicMedtronic
Product-carelink_2090_programmercarelink_2090_programmer_firmware29901_encore_programmer_firmwarecarelink_9790_programmer29901_encore_programmercarelink_9790_programmer_firmwareCareLink 9790 ProgrammerCareLink 2090 Programmer29901 Encore Programmer
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2018-10634
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.8||MEDIUM
EPSS-0.10% / 27.93%
||
7 Day CHG~0.00%
Published-13 Aug, 2018 | 22:00
Updated-22 May, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Cleartext Transmission of Sensitive Information

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.

Action-Not Available
Vendor-medtronicMedtronic
Product-minimed_530g_mmt-751_firmwareminimed_530g_mmt-751minimed_paradigm_508_insulin_pumpminimed_paradigm_revel_mmt-723_firmwareminimed_paradigm_revel_mmt-523k_firmwareminimed_paradigm_real-time_mmt-522_firmwareminimed_paradigm_revel_mmt-523minimed_paradigm_real-time_mmt-722_firmwareminimed_paradigm_revel_mmt-723kminimed_paradigm_revel_mmt-523_firmwareminimed_530g_mmt-551minimed_paradigm_revel_mmt-723k_firmwareminimed_paradigm_real-time_mmt-522minimed_paradigm_508_insulin_pump_firmwareminimed_paradigm_revel_mmt-523kminimed_530g_mmt-551_firmwareminimed_paradigm_real-time_mmt-722minimed_paradigm_revel_mmt-723MMT – 522(K) / MMT – 722(K) Paradigm REAL-TIMEMMT- 508 - MiniMed pumpMMT – 511 pump ParadigmMMT – 512 / MMT – 712 Paradigm x12MMT – 523(K) / MMT – 723(K) ParadigmMMT – 515 / MMT – 715 Paradigm x15MMT – 523 / MMT – 723 Paradigm RevelMMT – 522 / MMT – 722 Paradigm REAL-TIMEMMT – 551 / MMT – 751 MiniMed 530GMMT – 554 / MMT – 754 MiniMed Veo
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2018-10626
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.4||MEDIUM
EPSS-0.04% / 8.78%
||
7 Day CHG-0.00%
Published-10 Aug, 2018 | 18:00
Updated-22 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.

Action-Not Available
Vendor-medtronicMedtronic
Product-mycarelink_24952_patient_monitormycarelink_24950_patient_monitor_firmwaremycarelink_24952_patient_monitor_firmwaremycarelink_24950_patient_monitor24950 MyCareLink Monitor24952 MyCareLink Monitor
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2018-10622
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.9||MEDIUM
EPSS-0.06% / 18.70%
||
7 Day CHG~0.00%
Published-10 Aug, 2018 | 18:00
Updated-22 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink 24950 Patient Monitor Storing Passwords in a Recoverable Format

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.

Action-Not Available
Vendor-medtronicMedtronic
Product-mycarelink_24952_patient_monitormycarelink_24950_patient_monitor_firmwaremycarelink_24952_patient_monitor_firmwaremycarelink_24950_patient_monitor24950 MyCareLink Monitor24952 MyCareLink Monitor
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-10631
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.3||MEDIUM
EPSS-0.15% / 36.45%
||
7 Day CHG+0.02%
Published-13 Jul, 2018 | 19:00
Updated-26 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic N'Vision Clinician Programmer Protection Mechanism Failure

The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.

Action-Not Available
Vendor-medtronicMedtronicics_cert
Product-n\'vision_8840n\'vision_8870n\'vision_8870_firmwaren\'vision_8840_firmware8840 N’Vision Clinician Programmer8870 N’Vision removable Application Cardmedtronic_n_vision_clinician_programmer
CWE ID-CWE-693
Protection Mechanism Failure
CVE-2018-10596
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.1||HIGH
EPSS-0.19% / 41.26%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 18:00
Updated-22 May, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic 2090 Carelink Programmer Improper Restriction of Communication Channel to Intended Endpoints

Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-side (client) service responsible for this HTTP request does not check to ensure it is still connected to the VPN before making the HTTP request. Thus, an attacker could cause the VPN connection to terminate (through various methods and attack points) and intercept the HTTP request, responding with malicious updates via a man-in-the-middle attack. The affected products do not verify the origin or integrity of these updates, as it insufficiently relied on the security of the VPN. An attacker with remote network access to the programmer could influence these communications.

Action-Not Available
Vendor-medtronicMedtronic
Product-2090_carelink_programmer2090_carelink_programmer_firmware2090 CareLink Programmer29901 Encore Programmer
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-923
Improper Restriction of Communication Channel to Intended Endpoints
CVE-2018-8868
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.2||MEDIUM
EPSS-0.09% / 26.74%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 18:00
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

Action-Not Available
Vendor-medtronicMedtronic
Product-24950_mycarelink_monitor24950_mycarelink_monitor_firmware24952_mycarelink_monitor24952_mycarelink_monitor_firmware24950 MyCareLink Monitor24952 MyCareLink Monitor
CWE ID-CWE-749
Exposed Dangerous Method or Function
CVE-2018-8870
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.4||MEDIUM
EPSS-0.08% / 25.24%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 18:00
Updated-22 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic MyCareLink Patient Monitor Use of Hard-coded Password

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.

Action-Not Available
Vendor-medtronicMedtronic
Product-24950_mycarelink_monitor24950_mycarelink_monitor_firmware24952_mycarelink_monitor24952_mycarelink_monitor_firmware24950 MyCareLink Monitor24952 MyCareLink Monitor
CWE ID-CWE-259
Use of Hard-coded Password
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-8849
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.6||MEDIUM
EPSS-0.08% / 25.07%
||
7 Day CHG~0.00%
Published-18 May, 2018 | 13:00
Updated-27 Jun, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic N'Vision Clinician Programmer Missing Encryption of Sensitive Data

Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.

Action-Not Available
Vendor-medtronicMedtronic
Product-n\'vision_8840_firmwaren\'vision_8870_firmwaren\'vision_8870n\'vision_8840N'Vision Clinician Programmer8870 N’Vision removable Application Card
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2018-5448
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.8||MEDIUM
EPSS-0.13% / 33.19%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 18:00
Updated-22 May, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic 2090 Carelink Programmer Relative Path Traversal

Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.

Action-Not Available
Vendor-medtronicMedtronic
Product-2090_carelink_programmer2090_carelink_programmer_firmware2090 CareLink Programmer29901 Encore Programmer
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-23
Relative Path Traversal
CVE-2018-5446
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.9||MEDIUM
EPSS-0.09% / 26.55%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 18:00
Updated-22 May, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic 2090 Carelink Programmer Storing Passwords in a Recoverable Format

Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.

Action-Not Available
Vendor-medtronicMedtronic
Product-2090_carelink_programmer2090_carelink_programmer_firmware2090 CareLink Programmer29901 Encore Programmer
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2011-3386
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-4||MEDIUM
EPSS-1.11% / 77.23%
||
7 Day CHG~0.00%
Published-02 Sep, 2011 | 23:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service (adverse human health effects) via unspecified vectors involving wireless communications and knowledge of the device's serial number, as demonstrated by Jerome Radcliffe at the Black Hat USA conference in August 2011. NOTE: the vendor has disputed the severity of this issue, saying "we believe the risk of deliberate, malicious, or unauthorized manipulation of medical devices is extremely low... we strongly believe it would be extremely difficult for a third-party to wirelessly tamper with your insulin pump... you would be able to detect tones on the insulin pump that weren't intentionally programmed and could intervene accordingly."

Action-Not Available
Vendor-medtronicn/a
Product-paradigm_wireless_insulin_pumpn/a