Rocket.Chat before 3.11, 3.10.5, 3.9.7, 3.8.8 is vulnerable to persistent cross-site scripting (XSS) using nested markdown tags allowing a remote attacker to inject arbitrary JavaScript in a message. This flaw leads to arbitrary file read and RCE on Rocket.Chat desktop app.
A vulnerability was determined in code-projects Student Information System 2.0. The affected element is an unknown function of the file /register.php. This manipulation causes cross site scripting. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
Reflected XSS vulnerability in Micro Focus Application Automation Tools Plugin - Jenkins plugin. The vulnerability affects all version 6.7 and earlier versions.
BMC Remedy Mid Tier 9.1SP3 is affected by cross-site scripting (XSS). A DOM-based cross-site scripting vulnerability was discovered in a legacy utility.
The Attachments Handler plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via URL in all versions up to, and including, 1.1.7 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
A vulnerability in Pulse Connect Secure before 9.1R12 could allow a threat actor to perform a cross-site script attack against an authenticated administrator via an unsanitized web parameter.
The WP Social Ninja – Embed Social Feeds, Customer Reviews, Chat Widgets plugin for WordPress is vulnerable to Stored Cross-Site Scripting in all versions up to, and including, 3.20.3 due to insufficient input sanitization and output escaping on externally-sourced content. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page, granted they can post malicious content to a connected Google Business Profile or Facebook page.
The WP Directory Kit plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'order_by' parameter in all versions up to, and including, 1.4.5 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
A bug exist in the input parameter of Access Manager that allows supply of invalid character to trigger cross-site scripting vulnerability. This affects NetIQ Access Manager 4.5 and 5.0
There is a vulnerability in all angular versions before 1.5.0-beta.0, where after escaping the context of the web application, the web application delivers data to its users along with other trusted dynamic content, without validating it.
Webform Multiple File Upload module for Drupal 7.x contains a cross-site scripting (XSS) vulnerability in the file name renderer. An unauthenticated attacker can exploit this vulnerability by uploading a file with a malicious filename containing JavaScript code (e.g., "<img src=1 onerror=alert(document.domain)>") to a Webform node with a Multifile field where file type validation is disabled. This allows the execution of arbitrary scripts in the context of the victim's browser. The issue is present in a third-party library and has been addressed in a patch available at https://github.com/fyneworks/multifile/pull/44 . Users are advised to apply the provided patch or update to a fixed version of the module.
The login feature in "/cgi-bin/portal" in MAIL2000 through version 6.0 and 7.0 has a cross-site scripting (XSS) vulnerability, allowing execution of arbitrary code via any parameter. This vulnerability affects many mail system of governments, organizations, companies and universities.
The Tainacan plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'search' parameter in all versions up to, and including, 1.0.0 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Default installations of Zoho ManageEngine ServiceDesk Plus 10.0 before 10500 are vulnerable to XSS injected by a workstation local administrator. Using the installed program names of the computer as a vector, the local administrator can execute code on the Manage Engine ServiceDesk administrator side. At "Asset Home > Server > <workstation> > software" the administrator of ManageEngine can control what software is installed on the workstation. This table shows all the installed program names in the Software column. In this field, a remote attacker can inject malicious code in order to execute it when the ManageEngine administrator visualizes this page.
The CoSign Single Signon plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the `$_SERVER['PHP_SELF']` parameter in all versions up to, and including, 0.3.1 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
The Plugin Oficial WordPress plugin through 1.7.3 does not sanitise and escape a parameter before outputting it back in the page, leading to a Reflected Cross-Site Scripting which could be used against only unauthenticated users.
The Live Sales Notification for Woocommerce – Woomotiv plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'woomotiv_limit' parameter in all versions up to, and including, 3.6.3 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
The FilterPickerPopup.jspa resource in Jira before version 7.13.7, and from version 8.0.0 before version 8.3.3 allows remote attackers to inject arbitrary HTML or JavaScript via a cross site scripting (XSS) vulnerability in the searchOwnerUserName parameter.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Softmed SelfPatron allows Reflected XSS.This issue affects SelfPatron : before 2.0.
Possible Improper Neutralization of Input During Web Page Generation Vulnerability in eDirectory has been discovered in OpenTextâ„¢ eDirectory 9.2.3.0000.
The LiteSpeed Cache plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via URLs in all versions up to, and including, 7.5.0.1 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
An issue was discovered in Joomla! 2.5.0 through 3.9.24. Missing filtering of feed fields could lead to xss issues.
A security flaw has been discovered in chatwoot up to 4.7.0. This issue affects some unknown processing of the file app/javascript/shared/components/IframeLoader.vue of the component Admin Interface. The manipulation of the argument Link results in cross site scripting. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in code-projects Simple Food Ordering System 1.0. This affects an unknown part of the file /editcategory.php. The manipulation of the argument pname leads to cross site scripting. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
Crafter CMS Crafter Studio 3.0.1 is affected by: Cross Site Scripting (XSS), which allows remote attackers to steal users’ cookies.
D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) devices have XSS in the action parameter to htdocs/web/shareport.php.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Drupal CivicTheme Design System allows Cross-Site Scripting (XSS).This issue affects CivicTheme Design System: from 0.0.0 before 1.12.0.
An issue was discovered in KaiOS 2.5 and 2.5.1. The pre-installed Contacts application is vulnerable to HTML and JavaScript injection attacks. An attacker can send a vCard file to the victim that will inject HTML into the Contacts application (assuming the victim chooses to import the file). At a bare minimum, this allows an attacker to take control over the Contacts application's UI (e.g., display a malicious prompt to the user asking them to re-enter credentials such as their KaiOS credentials to continue using the application) and also allows an attacker to abuse any of the privileges available to the mobile application.
OpenCATS through 0.9.5-3 has multiple Cross-site Scripting (XSS) issues.
The proj_doc_edit_page.php Project Documentation feature in MantisBT before 2.21.3 has a stored cross-site scripting (XSS) vulnerability, allowing execution of arbitrary code (if CSP settings permit it) after uploading an attachment with a crafted filename. The code is executed when editing the document's page.
On all 7.x and 6.x versions (fixed in 8.0.0), undisclosed BIG-IQ pages have a reflected cross-site scripting vulnerability. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
baserCMS is a website development framework with WebAPI that runs on PHP8 and CakePHP4. There is a XSS Vulnerability in Favorites Feature to baserCMS. This issue has been patched in version 4.8.0.
Because of a lack of sanitization around error messages, multiple Reflective XSS issues exist in iTop through 2.6.0 via the param_file parameter to webservices/export.php, webservices/cron.php, or env-production/itop-backup/backup.php. By default, any XSS sent to the administrator can be transformed to remote command execution because of CVE-2018-10642 (still working through 2.6.0) The Reflective XSS can also become a stored XSS within the same account because of another vulnerability.
The Appointment Hour Booking plugin 1.1.44 for WordPress allows XSS via the E-mail field, as demonstrated by email_1.
On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3.1, and 14.1.x before 14.1.4.3, a DOM based cross-site scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
On BIG-IP version 16.0.x before 16.0.1, 15.1.x before 15.1.1, 14.1.x before 14.1.2.8, 13.1.x before 13.1.3.5, and all 12.1.x versions, a reflected Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility when Fraud Protection Service is provisioned and allows an attacker to execute JavaScript in the context of the current logged-in user. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Cross-site scripting vulnerability in Appointment and Event Booking Calendar for WordPress - Amelia versions prior to 1.0.76 allows a remote unauthenticated attacker to inject an arbitrary script by having a user who is logging in the WordPress where the product is installed visit a malicious URL.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Content output by the database auto-linking filter required additional sanitizing to prevent an XSS risk.
A cross-site scripting (XSS) vulnerability exists when Microsoft SQL Server Reporting Services (SSRS) does not properly sanitize a specially-crafted web request to an affected SSRS server, aka 'Microsoft SQL Server Reporting Services XSS Vulnerability'.
IBM InfoSphere Information Server 9.1, 11.3, and 11.5 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 125916.
An XSS vulnerability in qcopd-shortcode-generator.php in the Simple Link Directory plugin before 7.3.5 for WordPress allows remote attackers to inject arbitrary web script or HTML, because esc_html is not called for the "echo get_the_title()" or "echo $term->name" statement.
Bad validation logic in the Dart SDK versions prior to 2.12.3 allow an attacker to use an XSS attack via DOM clobbering. The validation logic in dart:html for creating DOM nodes from text did not sanitize properly when it came across template tags.
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `status` parameter of campaign-zone-zones.php. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code.
The WP Twitter Auto Publish plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via PostMessage in all versions up to, and including, 1.7.3 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
The Booking Calendar WordPress plugin before 8.9.2 does not sanitise and escape the booking_type parameter before outputting it back in an admin page, leading to a Reflected Cross-Site Scripting
This vulnerability is present in device_graph_page.php script, which is a part of the Advantech R-SeeNet web applications. A specially crafted URL by an attacker and visited by a victim can lead to arbitrary JavaScript code execution.
mongo-express is a web-based MongoDB admin interface, written with Node.js and express. 1: As mentioned in this issue: https://github.com/mongo-express/mongo-express/issues/577, when the content of a cell grows larger than supported size, clicking on a row will show full document unescaped, however this needs admin interaction on cell. 2: Data cells identified as media will be rendered as media, without being sanitized. Example of different renders: image, audio, video, etc. As an example of type 1 attack, an unauthorized user who only can send a large amount of data in a field of a document may use a payload with embedded javascript. This could send an export of a collection to the attacker without even an admin knowing. Other types of attacks such as dropping a database\collection are possible.
Cross-site scripting (XSS) vulnerability in vwrooms/js/jsor-jcarousel/examples/special_textscroller.php in the VideoWhisper Webcam plugins for Drupal 7.x allows remote attackers to inject arbitrary web script or HTML via a URL to a crafted SVG file in the feed parameter.