A vulnerability in the ArubaOS web-based management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.
A vulnerability in ArubaOS could allow an unauthenticated remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the web-based management interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.
A flaw was found in c-ares library, where a missing input validation check of host names returned by DNS (Domain Name Servers) can lead to output of wrong hostnames which might potentially lead to Domain Hijacking. The highest threat from this vulnerability is to confidentiality and integrity as well as system availability.
Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
Multiple cross-site scripting (XSS) vulnerabilities in Aruba Networks ClearPass Policy Manager (CPPM) before 6.4.5 allow remote administrators to inject arbitrary web script or HTML via unspecified vectors.
Vulnerabilities within the web-based management interface of ClearPass Policy Manager could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.
Cross-site scripting (XSS) vulnerability in Aruba Networks ClearPass Policy Manager (CPPM) before 6.4.5 allows remote attackers to inject arbitrary web script or HTML via the username parameter to tips/tipsLoginSubmit.action.
Vulnerabilities within the web-based management interface of ClearPass Policy Manager could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.
Multiple vulnerabilities within the web-based management interface of Aruba EdgeConnect Enterprise Orchestrator could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface in Aruba EdgeConnect Enterprise Orchestration Software version(s): Aruba EdgeConnect Enterprise Orchestrator (on-premises), Aruba EdgeConnect Enterprise Orchestrator-as-a-Service, Aruba EdgeConnect Enterprise Orchestrator-SP and Aruba EdgeConnect Enterprise Orchestrator Global Enterprise Tenant Orchestrators - Orchestrator 9.2.1.40179 and below, - Orchestrator 9.1.4.40436 and below, - Orchestrator 9.0.7.40110 and below, - Orchestrator 8.10.23.40015 and below, - Any older branches of Orchestrator not specifically mentioned.
A vulnerability in the web-based management interface of ClearPass Policy Manager could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface in Aruba ClearPass Policy Manager version(s): ClearPass Policy Manager 6.10.x: 6.10.7 and below and ClearPass Policy Manager 6.9.x: 6.9.12 and below.
Multiple vulnerabilities within the web-based management interface of Aruba EdgeConnect Enterprise Orchestrator could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface in Aruba EdgeConnect Enterprise Orchestration Software version(s): Aruba EdgeConnect Enterprise Orchestrator (on-premises), Aruba EdgeConnect Enterprise Orchestrator-as-a-Service, Aruba EdgeConnect Enterprise Orchestrator-SP and Aruba EdgeConnect Enterprise Orchestrator Global Enterprise Tenant Orchestrators - Orchestrator 9.2.1.40179 and below, - Orchestrator 9.1.4.40436 and below, - Orchestrator 9.0.7.40110 and below, - Orchestrator 8.10.23.40015 and below, - Any older branches of Orchestrator not specifically mentioned.
Multiple vulnerabilities within the web-based management interface of Aruba EdgeConnect Enterprise Orchestrator could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface in Aruba EdgeConnect Enterprise Orchestration Software version(s): Aruba EdgeConnect Enterprise Orchestrator (on-premises), Aruba EdgeConnect Enterprise Orchestrator-as-a-Service, Aruba EdgeConnect Enterprise Orchestrator-SP and Aruba EdgeConnect Enterprise Orchestrator Global Enterprise Tenant Orchestrators - Orchestrator 9.2.1.40179 and below, - Orchestrator 9.1.4.40436 and below, - Orchestrator 9.0.7.40110 and below, - Orchestrator 8.10.23.40015 and below, - Any older branches of Orchestrator not specifically mentioned.
A vulnerability has been identified in Desigo PXM30-1 (All versions < V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41), Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All versions < V02.20.126.11-41), Desigo PXM50-1 (All versions < V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41), PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All versions < V02.20.126.11-41), PXG3.W200-1 (All versions < V02.20.126.11-37), PXG3.W200-2 (All versions < V02.20.126.11-41). The device embedded browser does not prevent interaction with alternative URI schemes when redirected to corresponding resources by web application code. By setting the homepage URI, the favorite URIs, or redirecting embedded browser users via JavaScript code to alternative scheme resources, a remote low privileged attacker can perform a range of attacks against the device, such as read arbitrary files on the filesystem, execute arbitrary JavaScript code in order to steal or manipulate the information on the screen, or trigger denial of service conditions.
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.
A vulnerability within the web-based management interface of Aruba EdgeConnect Enterprise could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface in Aruba EdgeConnect Enterprise Software version(s): ECOS 9.2.1.0 and below; ECOS 9.1.3.0 and below; ECOS 9.0.7.0 and below; ECOS 8.3.7.1 and below.
A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.
Cross-site scripting (XSS) vulnerability in Aruba Networks ClearPass before 6.3.6 and 6.4.x before 6.4.1 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed into passing specially crafted, malicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), then JavaScript code can be returned and may then be executed by the user’s client. Various actions could be triggered by running malicious JavaScript code.
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not handle uploaded files correctly. An unauthenticated attacker could take advantage of this situation to store an XSS attack, which could - when a legitimate user accesses the error logs - perform arbitrary actions in the name of the user.
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly handle the input of a GET request parameter. The provided argument is directly reflected in the web server response. This could allow an unauthenticated attacker to perform reflected XSS attacks.
Cross-site request forgery (CSRF) vulnerability in the Insight module in Aruba Networks ClearPass before 6.3.6 and 6.4.x before 6.4.1 allows remote attackers to hijack the authentication of a logged in user via unspecified vectors.
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly sanitize the filenames before uploading. This could allow an authenticated remote attacker to compromise of integrity of the system.
A remote authenticated stored cross-site scripting (xss) vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.
A vulnerability in the ArubaOS web management interface could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface.
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.
A remote reflected cross-site scripting (XSS) vulnerability was discovered in Aruba ClearPass Policy Manager version(s): Prior to 6.9.5, 6.8.8-HF1, 6.7.14-HF1. A vulnerability in the guest portal interface of ClearPass could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the portal. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the guest portal interface.
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The User Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.
A remote cross-site scripting (XSS) vulnerability was discovered in Aruba AirWave Management Platform version(s): Prior to 8.2.13.0. Aruba has released upgrades for the Aruba AirWave Management Platform that address this security vulnerability.
A vulnerability within the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victims browser in the context of the affected interface.
A remote cross-site scripting (XSS) vulnerability was discovered in Aruba ClearPass Policy Manager version(s) prior to 6.9.5, 6.8.9, 6.7.14-HF1. Aruba has released patches for Aruba ClearPass Policy Manager that address this security vulnerability.
A remote cross-site scripting (XSS) vulnerability was discovered in Aruba ClearPass Policy Manager version(s) prior to 6.9.5, 6.8.9, 6.7.14-HF1. Aruba has released patches for Aruba ClearPass Policy Manager that address this security vulnerability.
A local cross-site scripting (XSS) vulnerability was discovered in Aruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series version(s): Aruba AOS-CX firmware: 10.04.xxxx - versions prior to 10.04.3070, 10.05.xxxx - versions prior to 10.05.0070, 10.06.xxxx - versions prior to 10.06.0110, 10.07.xxxx - versions prior to 10.07.0001. Aruba has released upgrades for Aruba AOS-CX devices that address this security vulnerability.
A remote authenticated stored cross-site scripting (xss) vulnerability was discovered in Aruba AirWave Management Platform version(s): Prior to 8.2.12.0. A vulnerability in the web-based management interface of AirWave could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the affected interface.
A remote unauthenticated stored cross-site scripting (XSS) vulnerability was discovered in Aruba ClearPass Policy Manager version(s): Prior to 6.9.5, 6.8.8-HF1, 6.7.14-HF1. A vulnerability in the web-based management interface of ClearPass could allow an unauthenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against an administrative user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the affected interface.
A remote reflected cross-site scripting (xss) vulnerability was discovered in Aruba AirWave Management Platform version(s): Prior to 8.2.12.0. A vulnerability in the web-based management interface of AirWave could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of certain components of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the AirWave management interface.
A remote cross-site scripting (xss) vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.
A reflected Cross-Site-Scripting (XSS) vulnerability has been identified in Siemens PLM Software TEAMCENTER (V9.1.2.5). If a user visits the login portal through the URL crafted by the attacker, the attacker can insert html/javascript and thus alter/rewrite the login portal page. Siemens PLM Software TEAMCENTER V9.1.3 and newer are not affected.
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
A vulnerability in the Aruba InstantOS and ArubaOS 10 web management interface could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the affected interface of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InstantOS that address this security vulnerability.
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Cross-site scripting (XSS) vulnerability in the dashboard of the ArubaOS Administration WebUI in Aruba Networks ArubaOS 6.2.x before 6.2.0.3, 6.1.3.x before 6.1.3.7, 6.1.x-FIPS before 6.1.4.3-FIPS, and 6.1.x-AirGroup before 6.1.3.6-AirGroup, as used by Mobility Controller, allows remote wireless access points to inject arbitrary web script or HTML via a crafted SSID.
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.