A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) Software could allow an unauthenticated, remote attacker to cause the web-based management interface to unexpectedly restart. The vulnerability is due to insufficient input validation on the web-based management interface. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to cause the interface to restart, resulting in a denial of service (DoS) condition.
IBM Security Guardium 10.6, 11.3, and 11.4 could allow an authenticated user to cause a denial of service due to due to improper input validation. IBM X-Force ID: 240894.
A flaw was found in the Red Hat Ceph Storage RGW in versions before 14.2.21. When processing a GET Request for a swift URL that ends with two slashes it can cause the rgw to crash, resulting in a denial of service. The greatest threat to the system is of availability.
Missing check in DataCommunicator class in com.vaadin:vaadin-server versions 8.0.0 through 8.14.0 (Vaadin 8.0.0 through 8.14.0) allows authenticated network attacker to cause heap exhaustion by requesting too many rows of data.
Tuta is an encrypted email service. Starting in version 3.118.12 and prior to version 3.119.10, an attacker is able to send a manipulated email so that the user can no longer use the app to get access to received emails. By sending a manipulated email, an attacker could put the app into an unusable state. In this case, a user can no longer access received e-mails. Since the vulnerability affects not only the app, but also the web application, a user in this case has no way to access received emails. This issue was tested with iOS and the web app, but it is possible all clients are affected. Version 3.119.10 fixes this issue.
GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels.
Hyperledger Fabric is an enterprise-grade permissioned distributed ledger framework for developing solutions and applications. If a gateway client application sends a malformed request to a gateway peer it may crash the peer node. Version 2.4.6 checks for the malformed gateway request and returns an error to the gateway client. There are no known workarounds, users must upgrade to version 2.4.6.
Improper input validation check logic vulnerability in libsmkvextractor prior to SMR Jun-2022 Release 1 allows attackers to trigger crash.
On F5 BIG-IP 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, 13.1.x versions prior to 13.1.5, and all versions of 12.1.x and 11.6.x, and F5 BIG-IQ Centralized Management all versions of 8.x and 7.x, when an IPv6 self IP address is configured and the ipv6.strictcompliance database key is enabled (disabled by default) on a BIG-IP system, undisclosed packets may cause decreased performance. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
Improper Input Validation vulnerability in Management Program in TXOne Networks Portable Inspector and Portable Inspector Pro Edition allows remote attacker to crash management service. The Denial of Service situation can be resolved by restarting the management service. This issue affects Portable Inspector: through 1.0.0; Portable Inspector Pro Edition: through 1.0.0.
Insufficient validation of filenames against control characters in Apache Subversion repositories served via mod_dav_svn allows authenticated users with commit access to commit a corrupted revision, leading to disruption for users of the repository. All versions of Subversion up to and including Subversion 1.14.4 are affected if serving repositories via mod_dav_svn. Users are recommended to upgrade to version 1.14.5, which fixes this issue. Repositories served via other access methods are not affected.
Improper access control of certain port in SmartThings prior to version 1.7.63.6 allows remote temporary denial of service.
Multiple vulnerabilities in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker with read-only privileges to cause the web UI software to become unresponsive and consume vty line instances, resulting in a denial of service (DoS) condition. These vulnerabilities are due to insufficient error handling in the web UI. An attacker could exploit these vulnerabilities by sending crafted HTTP packets to an affected device. A successful exploit could allow the attacker to cause the web UI software to become unresponsive and consume all available vty lines, preventing new session establishment and resulting in a DoS condition. Manual intervention would be required to regain web UI and vty session functionality. Note: These vulnerabilities do not affect the console connection.
Multiple vulnerabilities in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker with read-only privileges to cause the web UI software to become unresponsive and consume vty line instances, resulting in a denial of service (DoS) condition. These vulnerabilities are due to insufficient error handling in the web UI. An attacker could exploit these vulnerabilities by sending crafted HTTP packets to an affected device. A successful exploit could allow the attacker to cause the web UI software to become unresponsive and consume all available vty lines, preventing new session establishment and resulting in a DoS condition. Manual intervention would be required to regain web UI and vty session functionality. Note: These vulnerabilities do not affect the console connection.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
A vulnerability in the web server authentication of Cisco IOS XE Software could allow an authenticated, remote attacker to crash the web server on the device. The vulnerability is due to insufficient input validation during authentication. An attacker could exploit this vulnerability by entering unexpected characters during a valid authentication. A successful exploit could allow the attacker to crash the web server on the device, which must be manually recovered by disabling and re-enabling the web server.
An issue was discovered in Mattermost Server before 4.3.0, 4.2.1, and 4.1.2. It allows attackers to cause a denial of service (channel invisibility) via a misformatted post.