Tenda AX12 v22.03.01.21_CN was discovered to contain a stack overflow via the list parameter at /goform/SetNetControlList.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
There is a stack buffer overflow vulnerability in the formSetPPTPServer function of Tenda-AX3 router V16.03.12.10_CN. The v13 variable is directly retrieved from the http request parameter startIp. Then v13 will be splice to stack by function sscanf without any security check, which causes stack overflow. By POSTing the page /goform/SetPptpServerCfg with proper startIp, the attacker can easily perform remote code execution with carefully crafted overflow data.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the bandwidth parameter in the wifiRadioSetIndoor function.
A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the URLs parameter in the saveParentControlInfo function.
Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the setstaticroutecfg function.
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR.
A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapsk_crypto2_4g results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the day parameter in the openSchedWifi function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the S1 parameter in the SetSysTimeCfg function.
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable.
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the startip parameter in the SetPptpServerCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the security_5g parameter in the WifiBasicSet function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn parameter at /goform/WifiBasicSet.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function.
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function.
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function.
In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the ip parameter in the spdtstConfigAndStart function.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.
Tenda W20E router V15.11.0.6 contains a stack overflow in the function formSetPortMapping with post request 'goform/setPortMapping/'. This vulnerability allows attackers to cause a Denial of Service (DoS) or Remote Code Execution (RCE) via the portMappingServer, portMappingProtocol, portMappingWan, porMappingtInternal, and portMappingExternal parameters.
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.