Cross site scripting (XSS) vulnerability in Ice Hrm 29.0.0.OS, allows attackers to execute arbitrary code via the parameters to the /app/ endpoint.
The Pago por Redsys plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'Ds_MerchantParameters' parameter in all versions up to, and including, 1.0.12 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Persistent XSS exists in XSLT CMS via the create/?action=items.edit&type=Page "body" field.
Zoho ManageEngine OpManager 12.3 before build 123239 allows XSS in the Notes column of the Alarms section.
The wpForo plugin 1.6.5 for WordPress allows XSS involving the wpf-dw-td-value class of dashboard.php.
In Metinfo 6.1.3, include/interface/applogin.php allows setting arbitrary HTTP headers (including the Cookie header), and common.inc.php allows registering variables from the $_COOKIE value. This issue can, for example, be exploited in conjunction with CVE-2018-19835 to bypass many XSS filters such as the Chrome XSS filter.
The BP Email Assign Templates plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'page' parameter in all versions up to, and including, 1.5 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
An XSS issue was discovered in Steve Pallen Xain before 0.6.2 via the order parameter.
In Bootstrap before 3.4.0, XSS is possible in the affix configuration target property.
An issue was discovered in Artica Proxy 4.30.000000. There is a XSS vulnerability via the password parameter in /fw.login.php.
Adobe Experience Manager versions 6.4, 6.3, 6.2, 6.1, and 6.0 have a reflected cross-site scripting vulnerability. Successful exploitation could lead to sensitive information disclosure.
Cross-site scripting (XSS) vulnerability in Outlook Web Access (OWA) in Microsoft Exchange Server 2013 PS1, 2013 Cumulative Update 10, 2013 Cumulative Update 11, and 2016 allows remote attackers to inject arbitrary web script or HTML via a crafted URL, aka "Exchange Spoofing Vulnerability."
The 'sReferencia', 'sDescripcion', 'txtCodigo' and 'txtDescripcion' parameters, in the frmGestionStock.aspx and frmEditServicio.aspx files in TCMAN GIM v8.0.1, could allow an attacker to perform persistent XSS attacks.
The Easy Digital Downloads (EDD) PDF Stamper extension for WordPress, as used with EDD 1.8.x before 1.8.7, 1.9.x before 1.9.10, 2.0.x before 2.0.5, 2.1.x before 2.1.11, 2.2.x before 2.2.9, and 2.3.x before 2.3.7, has XSS because add_query_arg is misused.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/SharedCriteria.jsp" has reflected XSS via the ConnPoolName or GroupId parameter.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
If exploited, this cross-site scripting vulnerability could allow remote attackers to inject malicious code. This issue affects: QNAP Systems Inc. Music Station versions prior to 5.1.13; versions prior to 5.2.9; versions prior to 5.3.11.
The Team Members WordPress plugin before 5.3.2 does not validate and escape some of its shortcode attributes before outputting them back in a page/post where the shortcode is embed, which could allow users with the author role and above to perform Stored Cross-Site Scripting attacks.
IBM Security Identity Manager 6.0.0 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 153748.
The Markdown component in Evernote (Chinese) before 8.3.2 on macOS allows stored XSS, aka MAC-832.
Cross-site scripting (XSS) vulnerability in IBM Security Network Protection 3100, 4100, 5100, and 7100 devices with firmware 5.2 before 5.2.0.0-ISS-XGS-All-Models-Hotfix-FP0008 and 5.3 before 5.3.0.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
The Themify Builder plugin for WordPress is vulnerable to Reflected Cross-Site Scripting due to the use of add_query_arg without appropriate escaping on the URL in all versions up to, and including, 7.6.5. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "PresentSpace.jsp" has reflected XSS via the GroupId and ConnPoolName parameters.
Adobe Experience Manager Forms versions 6.2, 6.3 and 6.4 have a stored cross-site scripting vulnerability. Successful exploitation could lead to sensitive information disclosure.
prettyPhoto before 3.1.6 has js/jquery.prettyPhoto.js XSS.
A vulnerability, which was classified as problematic, was found in PHPGurukul Maid Hiring Management System 1.0. Affected is an unknown function of the file /admin/contactus.php of the component Contact Us Page. The manipulation of the argument page title leads to cross site scripting. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
The cross-site scripting vulnerability has been reported to affect earlier versions of Photo Station. If exploited, the vulnerability could allow remote attackers to inject malicious code. This issue affects: QNAP Systems Inc. Photo Station versions prior to 5.7.11; versions prior to 6.0.10.
The WP Datepicker plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'wpdp_get_selected_datepicker' parameter in all versions up to, and including, 2.1.4 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Vesta v1.0.0-5 was discovered to contain a cross-site scripting (XSS) vulnerability via the generate_response function at /web/api/v1/upload/UploadHandler.php.
A vulnerability, which was classified as problematic, has been found in CodeAstro Restaurant POS System 1.0. Affected by this issue is some unknown functionality of the file create_account.php. The manipulation of the argument Full Name leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-253010 is the identifier assigned to this vulnerability.
If exploited, this cross-site scripting vulnerability could allow remote attackers to inject malicious code. QNAP has already fixed the issue in the following QTS versions. QTS 4.4.2.1231 on build 20200302; QTS 4.4.1.1201 on build 20200130; QTS 4.3.6.1218 on build 20200214; QTS 4.3.4.1190 on build 20200107; QTS 4.3.3.1161 on build 20200109; QTS 4.2.6 on build 20200109.
An issue was discovered in hsweb 3.0.4. It is a reflected XSS vulnerability due to the absence of type parameter checking in FlowableModelManagerController.java.
Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted userâs web browser to gain access to the affected device.
The Push Notification for Post and BuddyPress plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'pushnotificationid' parameter in all versions up to, and including, 2.06 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
The Export Customers Data plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 't' parameter in all versions up to, and including, 1.2.3 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
SolidInvoice 2.3.7 and fixed in v.2.3.8 is vulnerable to Cross Site Scripting (XSS) in the Tax Rate functionality.
The animate-it plugin before 2.3.4 for WordPress has XSS.
SolidInvoice 2.3.7 and v.2.3.8 is vulnerable to Cross Site Scripting (XSS) in the client's functionality.
Cross-site scripting (XSS) vulnerability in the PHP League CommonMark library versions 0.15.6 through 0.18.x before 0.18.1 allows remote attackers to insert unsafe URLs into HTML (even if allow_unsafe_links is false) via a newline character (e.g., writing javascript as javascri%0apt).
Reflected cross site script issue in Micro Focus Solutions Business Manager (SBM) (formerly Serena Business Manager (SBM)) versions prior to 11.5.
Insufficiently strict origin checks during JIT payment app installation in Payments in Google Chrome prior to 70.0.3538.67 allowed a remote attacker to install a service worker for a domain that can host attacker controled files via a crafted HTML page.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/AdminAuthorisationFrame.jsp" has reflected XSS via the ConnPoolName or GroupId parameter.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "EditCurrentUser.jsp" has reflected XSS via the GroupId and ConnPoolName parameters.
A vulnerability was found in Jspxcms 10.2.0. It has been classified as problematic. Affected is an unknown function of the file /ext/collect/find_text.do. The manipulation leads to cross site scripting. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252996.
The WP-Appbox plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'page' parameter in all versions up to, and including, 4.5.3 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Possible Improper Neutralization of Input During Web Page Generation Vulnerability in eDirectory has been discovered in OpenText™ eDirectory 9.2.3.0000.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "GroupRessourceAdmin.jsp" has reflected XSS via the ConnPoolName parameter.
EMC RSA Web Threat Detection version 5.0, RSA Web Threat Detection version 5.1, RSA Web Threat Detection version 5.1.2 has a cross site scripting vulnerability that could potentially be exploited by malicious users to compromise the affected system.
Pega Platform from 7.3 to 8.7.3 is affected by an XSS issue due to a misconfiguration of a datapage setting.