Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
Draytek Vigor Routers firmware versions below 3.9.6/4.2.4, Access Points firmware versions below v1.4.0, Switches firmware versions below 2.6.7, and Myvigor firmware versions below 2.3.2 were discovered to use hardcoded encryption keys which allows attackers to bind any affected device to their own account. Attackers are then able to create WCF and DrayDDNS licenses and synchronize them from the website.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
OpenC3 COSMOS before v6.0.2 was discovered to contain hardcoded credentials for the Service Account.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.951 and Application prior to 20.0.2368 (VA and SaaS deployments) contain shared, hardcoded SSH host private keys in the appliance image. The same private host keys (RSA, ECDSA, and ED25519) are present across installations, rather than being uniquely generated per appliance. An attacker who obtains these private keys (for example from one compromised appliance image or another installation) can impersonate the appliance, decrypt or intercept SSH connections to appliances that use the same keys, and perform man-in-the-middle or impersonation attacks against administrative SSH sessions. This vulnerability has been identified by the vendor as: V-2024-011 — Hardcoded SSH Host Key.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use default, shared credentials for the administrative web interface.
MegaRAC Default Credentials Vulnerability
An issue was discovered in Fighting Cock Information System 1.0, which uses default credentials, but does not force nor prompt the administrators to change the credentials.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
In TOTOLINK T6 V4.1.5cu.709_B20210518, there is a hard coded password for root in /etc/shadow.sample.
Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system.
IBM Security Verify Access 10.0.0 through 10.0.9, 11.0.0, IBM Verify Identity Access Container 10.0.0 through 10.0.9, and 11.0.0, under certain configurations, contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
NETSCOUT nGeniusONE before 6.4.0 b2350 has Hardcoded Credentials that can be obtained from JAR files.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
NVIDIA Isaac Launchable contains a vulnerability where an attacker could exploit a hard-coded credential issue. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, denial of service, and data tampering.
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.
Use of Hard-coded Credentials in EntoneWebEngine in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series and Kami7B allows remote attackers to retrieve and modify the device settings.
IBM Concert 1.0.0 through 2.1.0 could allow a remote attacker to obtain sensitive information or perform unauthorized actions due to the use of hard coded user credentials.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Hardcoded Credentials exist in the APK for Ports 9091 and 9092. The dashcam's Android application contains hardcoded credentials that allow unauthorized access to device settings through ports 9091 and 9092. These credentials, stored in cleartext, can be exploited by an attacker who gains access to the dashcam's network.
TOTOLINK CP300 V2.0.4-B20201102 was discovered to contain a hardcoded password vulnerability in /etc/shadow.sample, which allows attackers to log in as root.
Seiko SkyBridge MB-A100/A110 v4.2.0 and below implements a hard-coded passcode for the root account. Attackers are able to access the passcord via the file /etc/ciel.cfg.
The MyCar Controls of AutoMobility Distribution Inc., mobile application contains hard-coded admin credentials. A remote unauthenticated attacker may be able to send commands to and retrieve data from a target MyCar unit. This may allow the attacker to learn the location of a target, or gain unauthorized physical access to a vehicle. This issue affects AutoMobility MyCar versions prior to 3.4.24 on iOS and versions prior to 4.1.2 on Android. This issue has additionally been fixed in Carlink, Link, Visions MyCar, and MyCar Kia.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
Hardcoded JWT Secret in AgileConfig <1.6.8 Server allows remote attackers to use the generated JWT token to gain administrator access.
By default, BMC PATROL Agent through 11.3.01 uses a static encryption key for encrypting/decrypting user credentials sent over the network to managed PATROL Agent services. If an attacker were able to capture this network traffic, they could decrypt these credentials and use them to execute code or escalate privileges on the network.
Gladinet CentreStack through 16.1.10296.56315 (fixed in 16.4.10315.56368) has a deserialization vulnerability due to the CentreStack portal's hardcoded machineKey use, as exploited in the wild in March 2025. This enables threat actors (who know the machineKey) to serialize a payload for server-side deserialization to achieve remote code execution. NOTE: a CentreStack admin can manually delete the machineKey defined in portal\web.config.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Simple Care software installations. This issue affects Estomed Sp. z o.o. Simple Care software in all versions. The software is no longer supported.
Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from an authentication bypass vulnerability, where a special username with a deterministic password can be leveraged to bypass authentication checks and execute OS commands as the root user.
Totolink A3600R_Firmware V4.1.2cu.5182_B20201102 contains a hard code password for root in /etc/shadow.sample.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.
An authentication bypass vulnerability exists in FileWave before 14.6.3 and 14.7.x before 14.7.2. Exploitation could allow an unauthenticated actor to gain access to the system with the highest authority possible and gain full control over the FileWave platform.
PanIndex is a network disk directory index. In Panindex prior to version 3.1.3, a hard-coded JWT key `PanIndex` is used. An attacker can use the hard-coded JWT key to sign JWT token and perform any actions as a user with admin privileges. Version 3.1.3 has a patch for the issue. As a workaround, one may change the JWT key in the source code before compiling the project.
Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is installed. As a result, unintended operations may be performed on the PC.
Synel SYnergy Fingerprint Terminals - CWE-798: Use of Hard-coded Credentials
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root.
Wavlink WN530HG4 M30HG4.V5030.191116 was discovered to contain a hardcoded encryption/decryption key for its configuration files at /etc_ro/lighttpd/www/cgi-bin/ExportAllSettings.sh.
Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments.
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/product.ini, which allows attackers to log in as root.
An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000.
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices.