D-Link DI_8004W 16.07.26A1 contains a command execution vulnerability in the jhttpd upgrade_filter_asp function.
D-Link DI-8300 v16.07.26A1 is vulnerable to command injection via the upgrade_filter_asp function.
A vulnerability classified as critical has been found in D-Link DIR-513 1.10. This affects the function formSetWanPPTPcallback of the file /goform/formSetWanPPTPpath of the component HTTP POST Request Handler. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
D-Link DIR-823G v1.0.2B05 was discovered to contain a stack overflow via parameter TXPower and GuardInt in SetWLanRadioSecurity.
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
In D-Link DIR-860L REVA FIRMWARE PATCH 1.10..B04, the Telnet service contains hardcoded credentials, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
Certain D-Link devices have a hardcoded Alphanetworks user account with TELNET access because of /etc/config/image_sign or /etc/alpha_config/image_sign. This affects DIR-600 B1 V2.01 for WW, DIR-890L A1 v1.03, DIR-615 J1 v100 (for DCN), DIR-645 A1 v1.03, DIR-815 A1 v1.01, DIR-823 A1 v1.01, and DIR-842 C1 v3.00.
D-Link DSL-2750B devices before 1.05 allow remote unauthenticated command injection via the login.cgi cli parameter, as exploited in the wild in 2016 through 2022.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
D-Link DIR-820LW REVB FIRMWARE PATCH 2.03.B01_TC contains hardcoded credentials in the Telnet service, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
D-Link DIR823G_V1.0.2B05 was discovered to contain a stack overflow via the NewPassword parameters in SetPasswdSettings.
D-Link DIR-823X AX3000 Dual-Band Gigabit Wireless Router v21_D240126 was discovered to contain a remote code execution (RCE) vulnerability in the ntp_zone_val parameter at /goform/set_ntp. This vulnerability is exploited via a crafted HTTP request.
D-Link DAP-2660 v1.13 was discovered to contain a buffer overflow via the f_ipv6_enable parameter at /bsc_ipv6. This vulnerability is exploited via a crafted POST request.
D-Link - CWE-294: Authentication Bypass by Capture-replay
D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
Missing authentication for critical function in DAP-1880AC firmware version 1.21 and earlier allows a remote attacker to login to the device as an authenticated user without the access privilege via unspecified vectors.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
SharePort Web Access on D-Link DIR-868L REVB through 2.03, DIR-885L REVA through 1.20, and DIR-895L REVA through 1.21 devices allows Authentication Bypass, as demonstrated by a direct request to folder_view.php or category_view.php.
D-Link DIR-601 B1 2.00NA devices are vulnerable to authentication bypass. They do not check for authentication at the server side and rely on client-side validation, which is bypassable. NOTE: this is an end-of-life product.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. Authentication can be bypassed when accessing cgi modules. This allows one to perform administrative tasks (e.g., modify the admin password) with no authentication.
The LAN-side Web-Configuration Interface has Stack-based Buffer Overflow vulnerability in the D-Link Wi-Fi router firmware DIR-890L DIR890LA1_FW107b09.bin and previous versions. The function created at 0x17958 of /htdocs/cgibin will call sprintf without checking the length of strings in parameters given by HTTP header and can be controlled by users easily. The attackers can exploit the vulnerability to carry out arbitrary code by means of sending a specially constructed payload to port 49152.
A vulnerability was identified in D-Link DIR-825 2.10. Affected by this vulnerability is the function get_ping_app_stat of the file ping_response.cgi of the component httpd. The manipulation of the argument ping_ipaddr leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the lanip parameter in /goform/setNetworkLan.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A cfm UDP service listening on port 65002 allows remote, unauthenticated exfiltration of administrative credentials.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A hard-coded account allows management-interface login with high privileges. The logged-in user can perform critical tasks and take full control of the device.
An issue was discovered on the D-Link DWR-932B router. qmiweb allows command injection with ` characters.
An issue was discovered on D-Link DIR-825 R1 devices through 3.0.1 before 2020-11-20. A buffer overflow in the web interface allows attackers to achieve pre-authentication remote code execution.
D-Link DIR-846 devices with firmware 100A35 allow remote attackers to execute arbitrary code as root via HNAP1/control/SetGuestWLanSettings.php.
Buffer overflow vulnerability in DLINK 619L version B 2.06beta via the curTime parameter on login.
An issue was discovered in apply.cgi on D-Link DAP-1520 devices before 1.10b04Beta02. Whenever a user performs a login action from the web interface, the request values are being forwarded to the ssi binary. On the login page, the web interface restricts the password input field to a fixed length of 15 characters. The problem is that validation is being done on the client side, hence it can be bypassed. When an attacker manages to intercept the login request (POST based) and tampers with the vulnerable parameter (log_pass), to a larger length, the request will be forwarded to the webserver. This results in a stack-based buffer overflow. A few other POST variables, (transferred as part of the login request) are also vulnerable: html_response_page and log_user.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. Affected is an unknown function of the file /cgi-bin/nas_sharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument system leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-259284. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as very critical, has been found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. This issue affects some unknown processing of the file /cgi-bin/nas_sharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument user with the input messagebus leads to hard-coded credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259283. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
The ping tool in multiple D-Link and TRENDnet devices allow remote attackers to execute arbitrary code via the ping_addr parameter to ping.ccp.
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify.
An issue in DLink DWR 2000M 5G CPE With Wifi 6 Ax1800 and Dlink DWR 5G CPE DWR-2000M_1.34ME allows a local attacker to execute arbitrary code via a crafted request.
Stack Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the ip parameter of the ip_position.asp function.
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
D-Link devices DIR_878 DIR_878_FW1.30B08_Hotfix_02 and DIR_882 DIR_882_FW1.30B06_Hotfix_02 were discovered to contain a command injection vulnerability in the system function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
D-Link DIR-619L 2.06B01 is vulnerable to Buffer Overflow in the formSysCmd function via the submit-url parameter.
The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023.
An issue in Dlink DIR-816A2 v.1.10CNB05 allows a remote attacker to execute arbitrary code via the wizardstep4_ssid_2 parameter in the sub_42DA54 function.
A command injection vulnerability exists in D-Link DAP-1650 devices when handling UPnP SUBSCRIBE messages. An unauthenticated attacker can exploit this vulnerability to gain command execution on the device as root.
A command injection vulnerability exists in the gena.cgi module of D-Link DAP-1650 devices. An unauthenticated attacker can exploit this vulnerability to gain command execution on the device as root.
There is a command injection vulnerability in the ssdpcgi_main function of cgibin binary in D-Link DIR-815 router firmware v1.04.
In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow.
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload.
D-Link DIR-882 DIR882A1_FW130B06 was discovered to contain a stack overflow via the sub_477AA0 function.
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.