Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-24978

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-14 Feb, 2023 | 10:36
Updated At-20 Mar, 2025 | 14:10
Rejected At-
Credits

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19788)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:14 Feb, 2023 | 10:36
Updated At:20 Mar, 2025 | 14:10
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19788)

Affected Products
Vendor
Siemens AGSiemens
Product
Tecnomatix Plant Simulation
Default Status
unknown
Versions
Affected
  • All versions < V2201.0006
Problem Types
TypeCWE IDDescription
CWECWE-824CWE-824: Access of Uninitialized Pointer
Type: CWE
CWE ID: CWE-824
Description: CWE-824: Access of Uninitialized Pointer
Metrics
VersionBase scoreBase severityVector
3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:14 Feb, 2023 | 11:15
Updated At:22 Feb, 2023 | 15:37

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19788)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Secondary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>tecnomatix_plant_simulation>>Versions before 2201.0006(exclusive)
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-824Primaryproductcert@siemens.com
CWE ID: CWE-824
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdfproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

509Records found

CVE-2023-38680
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-39419
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.64%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:21
Updated-11 Oct, 2024 | 22:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2023solid_edge
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-38683
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted TIFF file. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationTeamcenter Visualization V14.1JT2GoTeamcenter Visualization V13.2Teamcenter Visualization V14.2
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-38679
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21106)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-39185
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-39184
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-39186
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-10 Oct, 2024 | 20:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-39188
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-38526
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-parasolidteamcenter_visualizationParasolid V35.1Teamcenter Visualization V14.2Teamcenter Visualization V14.1Parasolid V34.1Parasolid V35.0Teamcenter Visualization V14.3
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-38681
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21270)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-38530
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-parasolidteamcenter_visualizationParasolid V35.1Teamcenter Visualization V14.2Teamcenter Visualization V14.1Parasolid V34.1Parasolid V35.0Teamcenter Visualization V14.3
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-39187
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-10 Oct, 2024 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-38682
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 26.33%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 13:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationTeamcenter Visualization V14.1JT2GoTeamcenter Visualization V13.2Teamcenter Visualization V14.2
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-38070
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.17%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-02 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)

Action-Not Available
Vendor-Siemens AG
Product-jt2gotecnomatix_plant_simulationteamcenter_visualizationTecnomatix Plant Simulation V2201Teamcenter Visualization V14.1Teamcenter Visualization V14.0Teamcenter Visualization V13.3JT2GoTecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Teamcenter Visualization V14.3
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-38072
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 11.17%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-02 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20825)

Action-Not Available
Vendor-Siemens AG
Product-jt2gotecnomatix_plant_simulationteamcenter_visualizationTecnomatix Plant Simulation V2201Teamcenter Visualization V14.1Teamcenter Visualization V14.0Teamcenter Visualization V13.3JT2GoTecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Teamcenter Visualization V14.3
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-38071
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.21%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-25 Nov, 2024 | 21:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)

Action-Not Available
Vendor-Siemens AG
Product-jt2gotecnomatix_plant_simulationteamcenter_visualizationTecnomatix Plant Simulation V2201Teamcenter Visualization V14.1Teamcenter Visualization V14.0Teamcenter Visualization V13.3JT2GoTecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Teamcenter Visualization V14.3
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-37375
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.26%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-07 Nov, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21060)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-37376
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.29%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-07 Nov, 2024 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains a type confusion vulnerability while parsing STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21051)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-843
Access of Resource Using Incompatible Type ('Type Confusion')
CVE-2023-38074
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.55%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-02 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a type confusion vulnerability while parsing WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20840)

Action-Not Available
Vendor-Siemens AG
Product-jt2gotecnomatix_plant_simulationteamcenter_visualizationTecnomatix Plant Simulation V2201Teamcenter Visualization V14.1Teamcenter Visualization V14.0Teamcenter Visualization V13.3JT2GoTecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Teamcenter Visualization V14.3
CWE ID-CWE-843
Access of Resource Using Incompatible Type ('Type Confusion')
CVE-2023-38075
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.16%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-02 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)

Action-Not Available
Vendor-Siemens AG
Product-jt2gotecnomatix_plant_simulationteamcenter_visualizationTecnomatix Plant Simulation V2201Teamcenter Visualization V14.1Teamcenter Visualization V14.0Teamcenter Visualization V13.3JT2GoTecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Teamcenter Visualization V14.3
CWE ID-CWE-416
Use After Free
CVE-2023-37374
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.26%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-08 Nov, 2024 | 16:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-38076
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 23.21%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-02 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)

Action-Not Available
Vendor-Siemens AG
Product-jt2gotecnomatix_plant_simulationteamcenter_visualizationTecnomatix Plant Simulation V2201Teamcenter Visualization V14.1Teamcenter Visualization V14.0Teamcenter Visualization V13.3JT2GoTecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Teamcenter Visualization V14.3
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-37248
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-08 Nov, 2024 | 17:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21155)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-39134
Matching Score-8
Assigner-GitHub, Inc.
ShareView Details
Matching Score-8
Assigner-GitHub, Inc.
CVSS Score-8.2||HIGH
EPSS-1.29% / 78.83%
||
7 Day CHG~0.00%
Published-31 Aug, 2021 | 16:55
Updated-04 Aug, 2024 | 01:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
UNIX Symbolic Link (Symlink) Following in @npmcli/arborist

`@npmcli/arborist`, the library that calculates dependency trees and manages the `node_modules` folder hierarchy for the npm command line interface, aims to guarantee that package dependency contracts will be met, and the extraction of package contents will always be performed into the expected folder. This is, in part, accomplished by resolving dependency specifiers defined in `package.json` manifests for dependencies with a specific name, and nesting folders to resolve conflicting dependencies. When multiple dependencies differ only in the case of their name, Arborist's internal data structure saw them as separate items that could coexist within the same level in the `node_modules` hierarchy. However, on case-insensitive file systems (such as macOS and Windows), this is not the case. Combined with a symlink dependency such as `file:/some/path`, this allowed an attacker to create a situation in which arbitrary contents could be written to any location on the filesystem. For example, a package `pwn-a` could define a dependency in their `package.json` file such as `"foo": "file:/some/path"`. Another package, `pwn-b` could define a dependency such as `FOO: "file:foo.tgz"`. On case-insensitive file systems, if `pwn-a` was installed, and then `pwn-b` was installed afterwards, the contents of `foo.tgz` would be written to `/some/path`, and any existing contents of `/some/path` would be removed. Anyone using npm v7.20.6 or earlier on a case-insensitive filesystem is potentially affected. This is patched in @npmcli/arborist 2.8.2 which is included in npm v7.20.7 and above.

Action-Not Available
Vendor-npmjsnpmOracle CorporationSiemens AG
Product-sinec_infrastructure_network_servicesarboristnpmgraalvmarborist
CWE ID-CWE-61
UNIX Symbolic Link (Symlink) Following
CWE ID-CWE-178
Improper Handling of Case Sensitivity
CVE-2023-37246
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.26%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-08 Nov, 2024 | 17:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21109)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-37247
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.26%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-08 Nov, 2024 | 17:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21138)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-28830
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.71%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-23 Oct, 2024 | 19:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Solid Edge SE2022 (All versions < V222.0 Update 13), Solid Edge SE2023 (All versions < V223.0 Update 4), Teamcenter Visualization V13.2 (All versions < V13.2.0.15), Teamcenter Visualization V13.3 (All versions < V13.3.0.11), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted ASM file. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edge_se2023teamcenter_visualizationsolid_edge_se2022Solid Edge SE2023Teamcenter Visualization V14.1Teamcenter Visualization V13.2Teamcenter Visualization V13.3JT2GoTeamcenter Visualization V14.2Solid Edge SE2022
CWE ID-CWE-416
Use After Free
CVE-2021-38405
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.27%
||
7 Day CHG~0.00%
Published-21 Nov, 2023 | 18:19
Updated-04 Aug, 2024 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Siemens Solid Edge, JT2Go, and Teamcenter Visualization Improper Restriction of Operations within the Bounds of a Memory Buffer

The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-32936
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.28%
||
7 Day CHG~0.00%
Published-17 Jun, 2021 | 00:00
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An out-of-bounds write issue exists in the DXF file-recovering procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_sdkteamcenter_visualizationDrawings SDK
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-37179
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.53% / 66.36%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13777)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2021_firmwareSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2023-33123
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 26.33%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Jan, 2025 | 01:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationTeamcenter Visualization V14.1Teamcenter Visualization V13.2Teamcenter Visualization V13.3Teamcenter Visualization V14.0JT2GoTeamcenter Visualization V14.2
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-33124
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.60%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Jan, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationTeamcenter Visualization V14.1Teamcenter Visualization V13.2Teamcenter Visualization V13.3Teamcenter Visualization V14.0JT2GoTeamcenter Visualization V14.2
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-33493
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.27%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-02 Aug, 2024 | 02:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-Solid Edgesolid_edge
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-33653
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.17% / 38.69%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-19 Sep, 2024 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femapsimcenter_femap
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-30796
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 26.33%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 22:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJT OpenJT Utilities
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-33492
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.27%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-02 Aug, 2024 | 02:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-Solid Edgesolid_edge
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-30986
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.46%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 11:51
Updated-28 Jan, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-30900
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.37%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Xpedition Layout Browser (All versions < VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-xpedition_layout_browserXpedition Layout Browser
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-30795
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 28.97%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt_openparasolidjt_utilitiesParasolid V34.0Parasolid V35.1JT UtilitiesParasolid V35.0JT OpenParasolid V34.1
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-27398
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.94% / 75.25%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-30033
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.02% / 2.37%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:16
Updated-12 Aug, 2025 | 20:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC PCS 7/OPEN OS V9.1SIMATIC S7-PLCSIM V20SIMATIC PCS 7 Advanced Process Functions V2.2TIA Portal Test Suite V19SIMATIC NET PC Software V17SIMATIC WinCC flexible ESSIMATIC PCS 7 PowerControlSIMATIC WinCC Visualization Architect (SiVArc) V20SIMATIC WinCC Visualization Architect (SiVArc) V18SIMATIC NET PC Software V19SIMATIC PCS 7 V10.0SIMATIC ProSave V20SIMATIC WinCC Runtime Professional V20SIMATIC S7-1500 Software Controller V2SIMATIC Process Historian 2024SIMIT Rapid TesterStandard PID CTRL ToolSIMATIC PCS 7 Basis Faceplates V9.1SIMATIC WinCC TeleControlSIMATIC WinCC Unified PC Runtime V18SIMATIC PDM V9.2SIMATIC S7-PLCSIM AdvancedSIMATIC eaSie Document SkillsSIMATIC WinCC Unified PC Runtime V19SIMATIC MTP CREATOR V3.xSIMATIC S7-PLCSIM V18SIMATIC PCS 7 Standard Chemical Library V9.1SIMATIC PCS neo V6.0SIMATIC Automation ToolSINAMICS Startdrive V19SIMATIC Safety MatrixSIMATIC MTP CREATOR V5.xSIMATIC S7-PCTModular PID CTRL ToolTeleControl Server Basic V3.1Automation License Manager V6.2SIMATIC S7-1500 Software Controller V3OpenPCS 7 V9.1SIMATIC D7-SYSSIMATIC WinCC Visualization Architect (SiVArc) V19SIMATIC NET PC Software V20SIMATIC Process Function Library (PFL) V4.0TIA Portal Test Suite V20SIMATIC ProSave V19SIMATIC WinCC Unified Line CoordinationSIMATIC PCS 7 Industry Library V9.1SIMATIC NET PC Software V18SIMATIC STEP 7 CFC V19SIMIT Simulation PlatformSIMATIC MTP CREATOR V4.xSIMATIC Logon V1.6SINEMA Remote Connect ClientSIMATIC Management AgentSIMATIC WinCC Visualization Architect (SiVArc) V17SIMATIC Route Control V10.0SIMATIC Management ConsoleSIMATIC PCS 7 TeleControlSIMATIC eaSie PCS 7 Skill PackageSINEC NMSAutomation License Manager V6.0SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)SIMATIC PCS 7 Advanced Process Functions V2.1Create MyConfig (CMC)SIMATIC eaSie Workflow SkillsSIMATIC MTP Integrator V1.xSIMATIC PCS 7 Advanced Process Graphics V10.0OpenPCS 7 V10.0SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0WinCC Panel Image SetupSIMATIC ODK 1500SSIMATIC ProSave V17SIMATIC MTP CREATOR V2.xSIMATIC STEP 7 V5.7FM Configuration PackageSIMATIC STEP 7 CFC V20TIA Portal Test Suite V17SIMATIC eaSie Core PackageCP PtP Param configuring interfaceSIMATIC PCS 7 V9.1MultiFieldbus Configuration Tool (MFCT)SIMATIC Logon V2.0SIMATIC Process Historian 2020TIA Portal Cloud ConnectorTIA AdministratorSIMATIC NET PC Software V16SIMATIC WinCC Unified SequenceSIMATIC BATCH V10.0SIMATIC Route Control V9.1SIMATIC TargetSIMATIC WinCC V7.5SINAMICS Startdrive V18SIMATIC PCS neo V5.0SIMATIC WinCC V8.1SIMATIC Control Function Library (CFL) V4.0SIMATIC Control Function Library (CFL) V2.0SIMATIC S7-PLCSIM V19SIMATIC Automation Tool SDK WindowsSINAMICS Startdrive V20SIMATIC PCS 7 Basis Library V9.1SIMATIC PCS 7 MPC ConfiguratorSIMATIC S7 F Systems V6.3Energy Support Library (EnSL)SINAMICS Startdrive V17SIMATIC Control Function Library (CFL) V3.0SIMATIC MTP Integrator V2.xSIMATIC PCS 7 Advanced Process Graphics V9.1SIMATIC PDM V9.3SIMATIC ProSave V18SIMATIC Energy Suite V18SIMATIC Control Function Library (CFL) V1.0.0SIMATIC WinCC Unified PC Runtime V20SIMATIC WinCC V8.0TIA Portal Test Suite V18SIMATIC BATCH V9.1SIMATIC Energy Suite V17SIMATIC PCS 7 Advanced Process Faceplates V9.1TIA Project-ServerCEMAT V10.0SIMATIC PCS 7 Industry Library V10.0SIMATIC PCS 7 Advanced Process Library V9.1SIMATIC PCS 7 Standard Chemical Library V10.0SIMATIC PCS 7 Industry Library V9.0SIMATIC WinCC Runtime ProfessionalTIA Project-Server V17SIMATIC S7-PLCSIM V17SIMATIC S7 F Systems V6.4SIMATIC PCS 7 Logic Matrix V9.1Siemens Network Planner (SINETPLAN)SIMATIC WinCC Runtime AdvancedSIMATIC PDM Maintenance Station V5.0SITRANSSIMATIC PCS 7 Basis Library V10.0SIMATIC PCS 7 Logic Matrix V10.0SIMATIC Process Historian 2022SIMATIC Energy Suite V19
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2023-27398
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.64%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:31
Updated-27 Feb, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20304)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27401
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20308, ZDI-CAN-20345)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27403
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.62%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains a memory corruption vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20303, ZDI-CAN-20348)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27405
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.41%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20432)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27400
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20300)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27406
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.37%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20449)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-26293
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.04% / 12.14%
||
7 Day CHG~0.00%
Published-11 Apr, 2023 | 09:03
Updated-25 Nov, 2024 | 21:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.

Action-Not Available
Vendor-Siemens AG
Product-tia_portalTotally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V15Totally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V18
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-32639
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 31.55%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-02 Aug, 2024 | 02:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)

Action-Not Available
Vendor-Siemens AG
Product-Tecnomatix Plant Simulation V2302tecnomatix_plant_simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24550
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.64%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2022Solid Edge SE2023
CWE ID-CWE-122
Heap-based Buffer Overflow
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 10
  • 11
  • Next
Details not found