CVE-2025-30033
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.02% / 2.29%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:16
Updated-12 Aug, 2025 | 20:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC PCS 7/OPEN OS V9.1SIMATIC S7-PLCSIM V20SIMATIC PCS 7 Advanced Process Functions V2.2TIA Portal Test Suite V19SIMATIC NET PC Software V17SIMATIC WinCC flexible ESSIMATIC PCS 7 PowerControlSIMATIC WinCC Visualization Architect (SiVArc) V20SIMATIC WinCC Visualization Architect (SiVArc) V18SIMATIC NET PC Software V19SIMATIC PCS 7 V10.0SIMATIC ProSave V20SIMATIC WinCC Runtime Professional V20SIMATIC S7-1500 Software Controller V2SIMATIC Process Historian 2024SIMIT Rapid TesterStandard PID CTRL ToolSIMATIC PCS 7 Basis Faceplates V9.1SIMATIC WinCC TeleControlSIMATIC WinCC Unified PC Runtime V18SIMATIC PDM V9.2SIMATIC S7-PLCSIM AdvancedSIMATIC eaSie Document SkillsSIMATIC WinCC Unified PC Runtime V19SIMATIC MTP CREATOR V3.xSIMATIC S7-PLCSIM V18SIMATIC PCS 7 Standard Chemical Library V9.1SIMATIC PCS neo V6.0SIMATIC Automation ToolSINAMICS Startdrive V19SIMATIC Safety MatrixSIMATIC MTP CREATOR V5.xSIMATIC S7-PCTModular PID CTRL ToolTeleControl Server Basic V3.1Automation License Manager V6.2SIMATIC S7-1500 Software Controller V3OpenPCS 7 V9.1SIMATIC D7-SYSSIMATIC WinCC Visualization Architect (SiVArc) V19SIMATIC NET PC Software V20SIMATIC Process Function Library (PFL) V4.0TIA Portal Test Suite V20SIMATIC ProSave V19SIMATIC WinCC Unified Line CoordinationSIMATIC PCS 7 Industry Library V9.1SIMATIC NET PC Software V18SIMATIC STEP 7 CFC V19SIMIT Simulation PlatformSIMATIC MTP CREATOR V4.xSIMATIC Logon V1.6SINEMA Remote Connect ClientSIMATIC Management AgentSIMATIC WinCC Visualization Architect (SiVArc) V17SIMATIC Route Control V10.0SIMATIC Management ConsoleSIMATIC PCS 7 TeleControlSIMATIC eaSie PCS 7 Skill PackageSINEC NMSAutomation License Manager V6.0SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)SIMATIC PCS 7 Advanced Process Functions V2.1Create MyConfig (CMC)SIMATIC eaSie Workflow SkillsSIMATIC MTP Integrator V1.xSIMATIC PCS 7 Advanced Process Graphics V10.0OpenPCS 7 V10.0SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0WinCC Panel Image SetupSIMATIC ODK 1500SSIMATIC ProSave V17SIMATIC MTP CREATOR V2.xSIMATIC STEP 7 V5.7FM Configuration PackageSIMATIC STEP 7 CFC V20TIA Portal Test Suite V17SIMATIC eaSie Core PackageCP PtP Param configuring interfaceSIMATIC PCS 7 V9.1MultiFieldbus Configuration Tool (MFCT)SIMATIC Logon V2.0SIMATIC Process Historian 2020TIA Portal Cloud ConnectorTIA AdministratorSIMATIC NET PC Software V16SIMATIC WinCC Unified SequenceSIMATIC BATCH V10.0SIMATIC Route Control V9.1SIMATIC TargetSIMATIC WinCC V7.5SINAMICS Startdrive V18SIMATIC PCS neo V5.0SIMATIC WinCC V8.1SIMATIC Control Function Library (CFL) V4.0SIMATIC Control Function Library (CFL) V2.0SIMATIC S7-PLCSIM V19SIMATIC Automation Tool SDK WindowsSINAMICS Startdrive V20SIMATIC PCS 7 Basis Library V9.1SIMATIC PCS 7 MPC ConfiguratorSIMATIC S7 F Systems V6.3Energy Support Library (EnSL)SINAMICS Startdrive V17SIMATIC Control Function Library (CFL) V3.0SIMATIC MTP Integrator V2.xSIMATIC PCS 7 Advanced Process Graphics V9.1SIMATIC PDM V9.3SIMATIC ProSave V18SIMATIC Energy Suite V18SIMATIC Control Function Library (CFL) V1.0.0SIMATIC WinCC Unified PC Runtime V20SIMATIC WinCC V8.0TIA Portal Test Suite V18SIMATIC BATCH V9.1SIMATIC Energy Suite V17SIMATIC PCS 7 Advanced Process Faceplates V9.1TIA Project-ServerCEMAT V10.0SIMATIC PCS 7 Industry Library V10.0SIMATIC PCS 7 Advanced Process Library V9.1SIMATIC PCS 7 Standard Chemical Library V10.0SIMATIC PCS 7 Industry Library V9.0SIMATIC WinCC Runtime ProfessionalTIA Project-Server V17SIMATIC S7-PLCSIM V17SIMATIC S7 F Systems V6.4SIMATIC PCS 7 Logic Matrix V9.1Siemens Network Planner (SINETPLAN)SIMATIC WinCC Runtime AdvancedSIMATIC PDM Maintenance Station V5.0SITRANSSIMATIC PCS 7 Basis Library V10.0SIMATIC PCS 7 Logic Matrix V10.0SIMATIC Process Historian 2022SIMATIC Energy Suite V19
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2024-35783
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-0.28% / 50.78%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-14 Jan, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC Process Historian 2020SIMATIC WinCC Runtime Professional V18SIMATIC PCS 7 V9.1SIMATIC WinCC Runtime Professional V19SIMATIC WinCC V7.5SIMATIC Process Historian 2022SIMATIC BATCH V9.1SIMATIC WinCC V7.4SIMATIC Information Server 2022SIMATIC WinCC V8.0SIMATIC Information Server 2020simatic_batchsimatic_wincc
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2023-46280
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-8.2||HIGH
EPSS-0.04% / 12.65%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:01
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC Automation ToolSIMATIC WinCC Runtime Professional V19SIMATIC WinCC V7.5Totally Integrated Automation Portal (TIA Portal) V19SIMATIC WinCC OA V3.17SIMATIC WinCC Runtime Professional V17SIMATIC NET PC Software V16SIMATIC NET PC Software V18SIMATIC WinCC Runtime Professional V16SINUMERIK ONE virtualSIMATIC NET PC Software V17SINAMICS StartdriveSecurity Configuration Tool (SCT)SIMATIC WinCC Runtime AdvancedSIMATIC PCS 7 V9.1SIMATIC WinCC OA V3.19SIMATIC BATCH V9.1SIMATIC PDM V9.2SIMATIC WinCC V7.4SINUMERIK PLC Programming ToolSIMATIC Route Control V9.1SIMATIC NET PC Software V19Totally Integrated Automation Portal (TIA Portal) V16SIMATIC WinCC V8.0SIMATIC WinCC Runtime Professional V18Totally Integrated Automation Portal (TIA Portal) V17SINEC NMSTotally Integrated Automation Portal (TIA Portal) V18SIMATIC WinCC OA V3.18SIMATIC STEP 7 V5TIA Portal Cloud ConnectorTotally Integrated Automation Portal (TIA Portal) V15.1SIMATIC S7-PCT
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-48364
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.07% / 23.18%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 08:59
Updated-18 Oct, 2024 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.

Action-Not Available
Vendor-Siemens AG
Product-openpcs_7simatic_winccsimatic_pcs_7simatic_route_controlsimatic_wincc_runtime_professionalsimatic_batchSIMATIC WinCC Runtime Professional V19SIMATIC PCS 7 V9.1OpenPCS 7 V9.1SIMATIC BATCH V9.1SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC Route Control V9.1SIMATIC WinCC V8.0SIMATIC WinCC Runtime Professional V18
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2023-48363
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.09% / 27.27%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 08:59
Updated-18 Oct, 2024 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.

Action-Not Available
Vendor-Siemens AG
Product-openpcs_7simatic_winccsimatic_pcs_7simatic_route_controlsimatic_wincc_runtime_professionalsimatic_batchSIMATIC WinCC Runtime Professional V19SIMATIC PCS 7 V9.1OpenPCS 7 V9.1SIMATIC BATCH V9.1SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC Route Control V9.1SIMATIC WinCC V8.0SIMATIC WinCC Runtime Professional V18
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2021-40359
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-7.7||HIGH
EPSS-0.47% / 63.53%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_route_controlsimaticpcs_7simatic_net_pcsimatic_batchSIMATIC NET PC Software V14SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC NET PC Software V15SIMATIC PCS 7 V9.0SIMATIC PCS 7 V9.1OpenPCS 7 V9.0SIMATIC BATCH V9.1OpenPCS 7 V8.2SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC Route Control V9.1SIMATIC BATCH V8.2SIMATIC Route Control V8.2SIMATIC Route Control V9.0OpenPCS 7 V9.1SIMATIC NET PC Software V16SIMATIC BATCH V9.0SIMATIC WinCC V16SIMATIC PCS 7 V8.2SIMATIC NET PC Software V17
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')