Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-26298

Summary
Assigner-hp
Assigner Org ID-74586083-13ce-40fd-b46a-8e5d23cfbcb2
Published At-12 Jun, 2023 | 21:20
Updated At-06 Jan, 2025 | 15:48
Rejected At-
Credits

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:hp
Assigner Org ID:74586083-13ce-40fd-b46a-8e5d23cfbcb2
Published At:12 Jun, 2023 | 21:20
Updated At:06 Jan, 2025 | 15:48
Rejected At:
▼CVE Numbering Authority (CNA)

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

Affected Products
Vendor
HP Inc.HP Inc.
Product
HP Device Manager
Versions
Affected
  • 5.0.9
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
N/A
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
x_transferred
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:hp-security-alert@hp.com
Published At:12 Jun, 2023 | 22:15
Updated At:06 Jan, 2025 | 16:15

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

HP Inc.
hp
>>hp_device_manager>>5.0
cpe:2.3:a:hp:hp_device_manager:5.0:-:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0
cpe:2.3:a:hp:hp_device_manager:5.0:sp1:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0
cpe:2.3:a:hp:hp_device_manager:5.0:sp2:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.3
cpe:2.3:a:hp:hp_device_manager:5.0.3:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.4
cpe:2.3:a:hp:hp_device_manager:5.0.4:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.5
cpe:2.3:a:hp:hp_device_manager:5.0.5:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.6
cpe:2.3:a:hp:hp_device_manager:5.0.6:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.7
cpe:2.3:a:hp:hp_device_manager:5.0.7:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.7.1
cpe:2.3:a:hp:hp_device_manager:5.0.7.1:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.8
cpe:2.3:a:hp:hp_device_manager:5.0.8:*:*:*:*:*:*:*
HP Inc.
hp
>>hp_device_manager>>5.0.9
cpe:2.3:a:hp:hp_device_manager:5.0.9:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842hp-security-alert@hp.com
Vendor Advisory
https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Source: hp-security-alert@hp.com
Resource:
Vendor Advisory
Hyperlink: https://support.hp.com/us-en/document/ish_7974907-7974931-16/hpsbhf03842
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

522Records found

CVE-2022-29184
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-5.29% / 89.82%
||
7 Day CHG~0.00%
Published-20 May, 2022 | 19:25
Updated-23 Apr, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection/Argument Injection in GoCD

GoCD is a continuous delivery server. In GoCD versions prior to 22.1.0, it is possible for existing authenticated users who have permissions to edit or create pipeline materials or pipeline configuration repositories to get remote code execution capability on the GoCD server via configuring a malicious branch name which abuses Mercurial hooks/aliases to exploit a command injection weakness. An attacker would require access to an account with existing GoCD administration permissions to either create/edit (`hg`-based) configuration repositories; create/edit pipelines and their (`hg`-based) materials; or, where "pipelines-as-code" configuration repositories are used, to commit malicious configuration to such an external repository which will be automatically parsed into a pipeline configuration and (`hg`) material definition by the GoCD server. This issue is fixed in GoCD 22.1.0. As a workaround, users who do not use/rely upon Mercurial materials can uninstall/remove the `hg`/Mercurial binary from the underlying GoCD Server operating system or Docker image.

Action-Not Available
Vendor-thoughtworksgocd
Product-gocdgocd
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2026-2956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 22:02
Updated-25 Feb, 2026 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
qinming99 dst-admin restore revertBackup command injection

A security flaw has been discovered in qinming99 dst-admin up to 1.5.0. This affects the function revertBackup of the file /home/restore. The manipulation of the argument Name results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-dst-admin_projectqinming99
Product-dst-admindst-admin
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2530
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG+0.09%
Published-16 Feb, 2026 | 02:32
Updated-23 Feb, 2026 | 10:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi AddMac command injection

A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-24685
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.4||CRITICAL
EPSS-0.05% / 15.85%
||
7 Day CHG~0.00%
Published-28 Jan, 2026 | 16:47
Updated-09 Feb, 2026 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OpenProject has Argument Injection on Repository module that allows Arbitrary File Write

OpenProject is an open-source, web-based project management software. Versions prior to 16.6.6 and 17.0.2 have an arbitrary file write vulnerability in OpenProject’s repository diff download endpoint (`/projects/:project_id/repository/diff.diff`) when rendering a single revision via git show. By supplying a specially crafted rev value (for example, `rev=--output=/tmp/poc.txt)`, an attacker can inject git show command-line options. When OpenProject executes the SCM command, Git interprets the attacker-controlled rev as an option and writes the output to an attacker-chosen path. As a result, any user with the `:browse_repository` permission on the project can create or overwrite arbitrary files that the OpenProject process user is permitted to write. The written contents consist of git show output (commit metadata and patch), but overwriting application or configuration files still leads to data loss and denial of service, impacting integrity and availability. The issue has been fixed in OpenProject 17.0.2 and 16.6.6.

Action-Not Available
Vendor-openprojectopf
Product-openprojectopenproject
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2534
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG+0.09%
Published-16 Feb, 2026 | 04:02
Updated-23 Feb, 2026 | 10:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 V2 mbox-config sub_44AC4C command injection

A vulnerability has been found in Comfast CF-N1 V2 2.6.0.2. The affected element is the function sub_44AC4C of the file /cgi-bin/mbox-config?method=SET&section=ptest_bandwidth. The manipulation of the argument bandwidth leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1 V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2535
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG+0.09%
Published-16 Feb, 2026 | 04:32
Updated-23 Feb, 2026 | 10:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 V2 mbox-config sub_44AB9C command injection

A vulnerability was found in Comfast CF-N1 V2 2.6.0.2. The impacted element is the function sub_44AB9C of the file /cgi-bin/mbox-config?method=SET&section=ptest_channel. The manipulation of the argument channel results in command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1 V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-26042
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-2.61% / 85.39%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the daretools binary functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-22688
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-10||CRITICAL
EPSS-0.34% / 56.55%
||
7 Day CHG~0.00%
Published-10 Jan, 2026 | 03:41
Updated-22 Jan, 2026 | 14:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeKnora has Command Injection in MCP stdio test

WeKnora is an LLM-powered framework designed for deep document understanding and semantic retrieval. Prior to version 0.2.5, there is a command injection vulnerability that allows authenticated users to inject stdio_config.command/args into MCP stdio settings, causing the server to execute subprocesses using these injected values. This issue has been patched in version 0.2.5.

Action-Not Available
Vendor-tencentTencent
Product-weknoraWeKnora
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-26085
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-2.66% / 85.52%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the httpd wlscan_ASP functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24393
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.71% / 71.86%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:24
Updated-16 Sep, 2024 | 23:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “check_vertica_upgrade” value for the “cpIp” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24390
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.82% / 74.14%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:27
Updated-16 Sep, 2024 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24394
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.71% / 71.86%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:22
Updated-17 Sep, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “update_checkfile” value for the “filename” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24392
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.71% / 71.86%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:26
Updated-16 Sep, 2024 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “feed_comm_test” value for the “feed” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24388
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.87% / 74.93%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:30
Updated-16 Sep, 2024 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-28353
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.89% / 89.38%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 00:00
Updated-01 Apr, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability in the TRENDnet TEW-827DRU router with firmware version 2.10B01. An attacker can inject commands into the post request parameters usapps.config.smb_admin_name in the apply.cgi interface, thereby gaining root shell privileges.

Action-Not Available
Vendor-n/aTRENDnet, Inc.
Product-tew-827drutew-827dru_firmwaren/atew-827dru_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24389
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.87% / 74.93%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:28
Updated-16 Sep, 2024 | 18:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “cert_utils” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2218
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 39.50%
||
7 Day CHG~0.00%
Published-09 Feb, 2026 | 06:02
Updated-23 Feb, 2026 | 09:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-933L alphapd setSystemAdmin command injection

A vulnerability was determined in D-Link DCS-933L up to 1.14.11. This affects an unknown function of the file /setSystemAdmin of the component alphapd. This manipulation of the argument AdminID causes command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-933ldcs-933l_firmwareDCS-933L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-2323
Matching Score-4
Assigner-SonicWall, Inc.
ShareView Details
Matching Score-4
Assigner-SonicWall, Inc.
CVSS Score-8.8||HIGH
EPSS-1.31% / 79.55%
||
7 Day CHG~0.00%
Published-29 Jul, 2022 | 19:15
Updated-03 Aug, 2024 | 00:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions

Action-Not Available
Vendor-SonicWall Inc.
Product-sws14-24_firmwaresws14-24sws12-10fpoe_firmwaresws14-48fpoesws12-8_firmwaresws12-8poesws12-8sws14-48fpoe_firmwaresws12-10fpoesws14-24fpoe_firmwaresws12-8poe_firmwaresws14-48sws14-48_firmwaresws14-24fpoeSonicWall Switch
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-3219
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.47% / 64.18%
||
7 Day CHG~0.00%
Published-03 Jun, 2020 | 17:41
Updated-15 Nov, 2024 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Web UI Command Injection Vulnerability

A vulnerability in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker to inject and execute arbitrary commands with administrative privileges on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input to the web UI. A successful exploit could allow an attacker to execute arbitrary commands with administrative privileges on an affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software 16.1.1
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2026-2168
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.08% / 24.70%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M921 formLtefotaUpgradeQuectel sub_419920 command injection

A flaw has been found in D-Link DWR-M921 1.1.50. This affects the function sub_419920 of the file /boafrm/formLtefotaUpgradeQuectel. This manipulation of the argument fota_url causes command injection. It is possible to initiate the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m921dwr-m921_firmwareDWR-M921
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2135
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.09%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 04:32
Updated-23 Feb, 2026 | 09:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
UTT HiPER 810 formPdbUpConfig sub_43F020 command injection

A vulnerability was detected in UTT HiPER 810 1.7.4-141218. The impacted element is the function sub_43F020 of the file /goform/formPdbUpConfig. Performing a manipulation of the argument policyNames results in command injection. It is possible to initiate the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-uttUTT
Product-810810_firmwareHiPER 810
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2169
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.08% / 24.70%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M921 formLtefotaUpgradeFibocom command injection

A vulnerability has been found in D-Link DWR-M921 1.1.50. This impacts an unknown function of the file /boafrm/formLtefotaUpgradeFibocom. Such manipulation of the argument fota_url leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m921dwr-m921_firmwareDWR-M921
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-2234
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.9||CRITICAL
EPSS-0.45% / 63.33%
||
7 Day CHG~0.00%
Published-24 Aug, 2022 | 15:15
Updated-16 Apr, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
mySCADA myPRO Command Injection

An authenticated mySCADA myPRO 8.26.0 user may be able to modify parameters to run commands directly in the operating system.

Action-Not Available
Vendor-myscadamySCADA Technologies
Product-mypromySCADA myPRO
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2167
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.16% / 84.02%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:02
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink WA300 cstecgi.cgi setAPNetwork os command injection

A vulnerability was detected in Totolink WA300 5.2cu.7112_B20190227. The impacted element is the function setAPNetwork of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument Ipaddr results in os command injection. The attack may be performed from remote. The exploit is now public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-wa300wa300_firmwareWA300
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-22688
Matching Score-4
Assigner-Synology Inc.
ShareView Details
Matching Score-4
Assigner-Synology Inc.
CVSS Score-8.8||HIGH
EPSS-1.02% / 76.96%
||
7 Day CHG~0.00%
Published-25 Mar, 2022 | 06:55
Updated-14 Jan, 2025 | 19:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements used in a command ('Command Injection') vulnerability in File service functionality in Synology DiskStation Manager (DSM) before 6.2.4-25556-2 allows remote authenticated users to execute arbitrary commands via unspecified vectors.

Action-Not Available
Vendor-Synology, Inc.
Product-diskstation_managerDiskStation Manager (DSM)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2194
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 8.32%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 23:32
Updated-23 Feb, 2026 | 09:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 start_proxy_client_email command injection

A flaw has been found in D-Link DI-7100G C1 24.04.18D1. This affects the function start_proxy_client_email. Executing a manipulation can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1di-7100g_c1_firmwareDI-7100G C1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2991
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.59% / 89.01%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1326
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.67% / 85.54%
||
7 Day CHG+0.50%
Published-22 Jan, 2026 | 13:32
Updated-23 Feb, 2026 | 08:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink NR1800X POST Request cstecgi.cgi setWanCfg command injection

A weakness has been identified in Totolink NR1800X 9.1.0u.6279_B20210910. This vulnerability affects the function setWanCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. This manipulation of the argument Hostname causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-TOTOLINK
Product-nr1800x_firmwarenr1800xNR1800X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1544
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 25.36%
||
7 Day CHG~0.00%
Published-28 Jan, 2026 | 21:32
Updated-23 Feb, 2026 | 09:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_mode sub_41E2A0 os command injection

A security flaw has been discovered in D-Link DIR-823X 250416. Impacted is the function sub_41E2A0 of the file /goform/set_mode. Performing a manipulation of the argument lan_gateway results in os command injection. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-1327
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.69% / 71.38%
||
7 Day CHG+0.13%
Published-22 Jan, 2026 | 14:02
Updated-23 Feb, 2026 | 08:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink NR1800X POST Request cstecgi.cgi setTracerouteCfg command injection

A security vulnerability has been detected in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Such manipulation of the argument command leads to command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-nr1800x_firmwarenr1800xNR1800X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-0641
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.08% / 86.52%
||
7 Day CHG~0.00%
Published-06 Jan, 2026 | 19:02
Updated-23 Feb, 2026 | 08:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK WA300 cstecgi.cgi sub_401510 command injection

A security vulnerability has been detected in TOTOLINK WA300 5.2cu.7112_B20190227. This vulnerability affects the function sub_401510 of the file cstecgi.cgi. The manipulation of the argument UPLOAD_FILENAME leads to command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-wa300wa300_firmwareWA300
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1548
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.64% / 70.25%
||
7 Day CHG~0.00%
Published-28 Jan, 2026 | 22:32
Updated-23 Feb, 2026 | 09:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink A7000R cstecgi.cgi CloudACMunualUpdateUserdata command injection

A flaw has been found in Totolink A7000R 4.1cu.4154. This impacts the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. This manipulation of the argument url causes command injection. The attack can be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a7000ra7000r_firmwareA7000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1624
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.02% / 3.73%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 22:02
Updated-23 Feb, 2026 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M961 formLtefotaUpgradeFibocom command injection

A security vulnerability has been detected in D-Link DWR-M961 1.1.47. The affected element is an unknown function of the file /boafrm/formLtefotaUpgradeFibocom. Such manipulation of the argument fota_url leads to command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m961dwr-m961_firmwareDWR-M961
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1324
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.28% / 51.31%
||
7 Day CHG+0.06%
Published-22 Jan, 2026 | 13:02
Updated-23 Feb, 2026 | 08:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Sangfor Operation and Maintenance Management System SSH Protocol session SessionController os command injection

A vulnerability was identified in Sangfor Operation and Maintenance Management System up to 3.0.12. Affected by this issue is the function SessionController of the file /isomp-protocol/protocol/session of the component SSH Protocol Handler. The manipulation of the argument keypassword leads to os command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Sangfor Technologies Inc.
Product-operation_and_maintenance_security_management_systemOperation and Maintenance Management System
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-1066
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.25% / 48.40%
||
7 Day CHG-1.49%
Published-17 Jan, 2026 | 21:02
Updated-27 Feb, 2026 | 03:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
kalcaddle kodbox Compression zip command injection

A vulnerability was detected in kalcaddle kodbox up to 1.61.10. This issue affects some unknown processing of the file /?explorer/index/zip of the component Compression Handler. The manipulation results in command injection. The attack may be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-kodcloudkalcaddle
Product-kodboxkodbox
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-38193
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.88% / 75.02%
||
7 Day CHG~0.00%
Published-21 Oct, 2023 | 00:00
Updated-16 Sep, 2024 | 13:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in SuperWebMailer 9.00.0.01710. It allows Remote Code Execution via a crafted sendmail command line.

Action-Not Available
Vendor-superwebmailern/a
Product-superwebmailern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1596
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.04% / 13.21%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 15:32
Updated-23 Feb, 2026 | 09:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M961 formLtefotaUpgradeQuectel sub_419920 command injection

A flaw has been found in D-Link DWR-M961 1.1.47. This vulnerability affects the function sub_419920 of the file /boafrm/formLtefotaUpgradeQuectel. This manipulation of the argument fota_url causes command injection. The attack is possible to be carried out remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m961dwr-m961_firmwareDWR-M961
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-3718
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-8.8||HIGH
EPSS-1.10% / 77.78%
||
7 Day CHG~0.00%
Published-01 Aug, 2023 | 18:25
Updated-22 Oct, 2024 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in AOS-CX Command Line Interface

An authenticated command injection vulnerability exists in the AOS-CX command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands on the underlying operating system as a privileged user on the affected switch. This allows an attacker to fully compromise the underlying operating system on the device running AOS-CX.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)
Product-aruba_cx_6200marubaos-cxaruba_cx_8400aruba_cx_6200faruba_cx_8320-32aruba_cx_6200m_24garuba_cx_9300_32daruba_cx_4100iaruba_cx_8360-32y4caruba_cx_8360-16y2caruba_cx_6000_24garuba_cx_10000-48y6aruba_cx_8320-48paruba_cx_6300m_48garuba_cx_8360-48y6caruba_cx_6300m_24paruba_cx_8360-12caruba_cx_6000_12garuba_cx_8360-48xt4caruba_cx_6000_48garuba_cx_6100aruba_cx_6410aruba_cx_8325-32caruba_cx_8360-24xf2caruba_cx_8325-48y8caruba_cx_6200f_48garuba_cx_6405Aruba CX Switchesaruba_cx_switches
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.30%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-37469
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-0.41% / 60.61%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 22:12
Updated-02 Oct, 2024 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CasaOS Command Injection vulnerability

CasaOS is an open-source personal cloud system. Prior to version 0.4.4, if an authenticated user using CasaOS is able to successfully connect to a controlled SMB server, they are able to execute arbitrary commands. Version 0.4.4 contains a patch for the issue.

Action-Not Available
Vendor-icewhaleIceWhaleTechicewhaletech
Product-casaosCasaOScasaos-userservice
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-35932
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.1||HIGH
EPSS-0.84% / 74.46%
||
7 Day CHG~0.00%
Published-23 Jun, 2023 | 21:05
Updated-27 Nov, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
jcvi vulnerable to Configuration Injection due to unsanitized user input

jcvi is a Python library to facilitate genome assembly, annotation, and comparative genomics. A configuration injection happens when user input is considered by the application in an unsanitized format and can reach the configuration file. A malicious user may craft a special payload that may lead to a command injection. The impact of a configuration injection may vary. Under some conditions, it may lead to command injection if there is for instance shell code execution from the configuration file values. This vulnerability does not currently have a fix.

Action-Not Available
Vendor-jcvi_projecttanghaibao
Product-jcvijcvi
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-1284
Improper Validation of Specified Quantity in Input
CVE-2020-25079
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-48.27% / 97.67%
||
7 Day CHG~0.00%
Published-02 Sep, 2020 | 15:33
Updated-07 Nov, 2025 | 22:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-08-26||Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. cgi-bin/ddns_enc.cgi allows authenticated command injection.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dcs-4603dcs-2670l_firmwaredcs-4622dcs-2670ldcs-4802e_firmwaredcs-2530ldcs-4802edcs-p703dcs-4603_firmwaredcs-4622_firmwaredcs-4703edcs-4703e_firmwaredcs-4705edcs-4705e_firmwaredcs-2530l_firmwaredcs-4701edcs-4701e_firmwaredcs-p703_firmwaren/aDCS-2530L and DCS-2670L Devices
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-20926
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.3||MEDIUM
EPSS-0.85% / 74.56%
||
7 Day CHG~0.00%
Published-10 Nov, 2022 | 17:36
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centerCisco Firepower Management Center
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-36458
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.3||MEDIUM
EPSS-2.63% / 85.44%
||
7 Day CHG~0.00%
Published-05 Jul, 2023 | 20:57
Updated-18 Oct, 2024 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
1Panel vulnerable to ommand injection when entering the container terminal

1Panel is an open source Linux server operation and maintenance management panel. Prior to version 1.3.6, an authenticated attacker can craft a malicious payloads to achieve command injection when entering the container terminal. The vulnerability has been fixed in v1.3.6.

Action-Not Available
Vendor-FIT2CLOUD Inc.1Panel (FIT2CLOUD Inc.)
Product-1panel1Panel1panel
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-25847
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-8.8||HIGH
EPSS-1.50% / 80.87%
||
7 Day CHG~0.00%
Published-29 Dec, 2020 | 07:10
Updated-16 Sep, 2024 | 16:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection Vulnerability in QTS and QuTS hero

This command injection vulnerability allows attackers to execute arbitrary commands in a compromised application. QNAP have already fixed this vulnerability in the following versions of QTS and QuTS hero.

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-quts_heroqtsQuTS heroQTS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8818
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.48%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 22:32
Updated-04 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setLan setDFSSetting os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-36415
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-8.8||HIGH
EPSS-1.06% / 77.33%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 17:08
Updated-14 Apr, 2025 | 22:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Azure Identity SDK Remote Code Execution Vulnerability

Azure Identity SDK Remote Code Execution Vulnerability

Action-Not Available
Vendor-Microsoft Corporation
Product-azure_identity_sdkAzure Identity SDK for .NETAzure Identity SDK for PythonAzure Identity SDK for JavaScriptAzure Identity SDK for Java
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-36457
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.3||MEDIUM
EPSS-2.63% / 85.44%
||
7 Day CHG~0.00%
Published-05 Jul, 2023 | 20:57
Updated-18 Oct, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
1Panel vulnerable to command injection when adding container repositories

1Panel is an open source Linux server operation and maintenance management panel. Prior to version 1.3.6, an authenticated attacker can craft a malicious payload to achieve command injection when adding container repositories. The vulnerability has been fixed in v1.3.6.

Action-Not Available
Vendor-FIT2CLOUD Inc.1Panel (FIT2CLOUD Inc.)
Product-1panel1Panel1panel
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-35035
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.25% / 84.33%
||
7 Day CHG~0.00%
Published-12 Jun, 2023 | 00:00
Updated-03 Jan, 2025 | 23:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Atos Unify OpenScape 4000 Assistant V10 R1 before V10 R1.42.0 and V10 R1.34.8, Assistant V10 R0, Manager V10 R1 before V10 R1.42.0 and V10 R1.34.8, and Manager V10 R0 allow command injection by authenticated users, aka OSFOURK-23557.

Action-Not Available
Vendor-atosn/a
Product-unify_openscape_4000_managerunify_openscape_4000_assistantn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-34213
Matching Score-4
Assigner-Moxa Inc.
ShareView Details
Matching Score-4
Assigner-Moxa Inc.
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.41%
||
7 Day CHG~0.00%
Published-17 Aug, 2023 | 02:20
Updated-28 Oct, 2024 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Second Order Command-injection Vulnerability in the Key-generation Function

TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.

Action-Not Available
Vendor-Moxa Inc.
Product-tn-5900_firmwaretn-5900TN-5900 Seriestn-5900
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • ...
  • 10
  • 11
  • Next
Details not found