A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise.
TIANJIE CPE906-3 is vulnerable to password disclosure. This is present on Software Version WEB5.0_LCD_20200513, Firmware Version MV8.003, and Hardware Version CPF906-V5.0_LCD_20200513.
The WMS module lacks the authentication mechanism in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
An access control issue in Harbor v1.X.X to v2.5.3 allows attackers to access public and private image repositories without authentication. NOTE: the vendor's position is that this "is clearly described in the documentation as a feature."
An attacker with network access to the affected PLC (CJ-series and CS-series PLCs, all versions) may use a network protocol to read and write files on the PLC internal memory and memory card.
Missing authentication in /admin/student.php and /admin/teacher.php in ProjectWorlds Online Time Table Generator 1.0 allows remote attackers to obtain sensitive information (including plaintext password field values) via direct HTTP GET requests to these endpoints without a valid session.
A vulnerability classified as problematic has been found in SourceCodester Book Store Management System 1.0. This affects an unknown part of the file /bsms_ci/index.php/user/edit_user/. The manipulation of the argument password leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-214587.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1
Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: Admin Console). The supported version that is affected is 12.2.1.4.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Access Manager accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Free5gc v3.2.1 is vulnerable to Information disclosure.
Dapr Dashboard v0.1.0 through v0.10.0 is vulnerable to Incorrect Access Control that allows attackers to obtain sensitive data.
On Linksys E5350 WiFi Router with firmware version 1.0.00.037 and lower, (and potentially other vendors/devices due to code reuse), the /SysInfo.htm URI does not require a session ID. This web page calls a show_sysinfo function which retrieves WPA passwords, SSIDs, MAC Addresses, serial numbers, WPS Pins, and hardware/firmware versions, and prints this information into the web page. This web page is visible when remote management is enabled. A user who has access to the web interface of the device can extract these secrets. If the device has remote management enabled and is connected directly to the internet, this vulnerability is exploitable over the internet without interaction.
An issue was discovered in the A4N (Aremis 4 Nomad) application 1.5.0 for Android. It possesses an authentication mechanism; however, some features do not require any token or cookie in a request. Therefore, an attacker may send a simple HTTP request to the right endpoint, and obtain authorization to retrieve application data.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
Mattermost versions <11 fail to enforce multi-factor authentication on WebSocket connections which allows unauthenticated users to access sensitive information via WebSocket events
Splunk Enterprise deployment servers in versions before 9.0 allow unauthenticated downloading of forwarder bundles. Remediation requires you to update the deployment server to version 9.0 and Configure authentication for deployment servers and clients (https://docs.splunk.com/Documentation/Splunk/9.0.0/Security/ConfigDSDCAuthEnhancements#Configure_authentication_for_deployment_servers_and_clients). Once enabled, deployment servers can manage only Universal Forwarder versions 9.0 and higher. Though the vulnerability does not directly affect Universal Forwarders, remediation requires updating all Universal Forwarders that the deployment server manages to version 9.0 or higher prior to enabling the remediation.
Dell Storage Center - Dell Storage Manager, version(s) DSM 20.1.21, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.
A certain router administration interface (that includes Realtek APMIB 0.11f for Boa 0.94.14rc21) allows remote attackers to retrieve the configuration, including sensitive data (usernames and passwords). This affects TOTOLINK A3002RU through 2.0.0, A702R through 2.1.3, N301RT through 2.1.6, N302R through 3.4.0, N300RT through 3.4.0, N200RE through 4.0.0, N150RT through 3.4.0, and N100RE through 3.4.0; Rutek RTK 11N AP through 2019-12-12; Sapido GR297n through 2019-12-12; CIK TELECOM MESH ROUTER through 2019-12-12; KCTVJEJU Wireless AP through 2019-12-12; Fibergate FGN-R2 through 2019-12-12; Hi-Wifi MAX-C300N through 2019-12-12; HCN MAX-C300N through 2019-12-12; T-broad GN-866ac through 2019-12-12; Coship EMTA AP through 2019-12-12; and IO-Data WN-AC1167R through 2019-12-12.
D-Link DAP-1320 A2-V1.21 routers have some web interfaces without authentication requirements, as demonstrated by uplink_info.xml. An attacker can remotely obtain a user's Wi-Fi SSID and password, which could be used to connect to Wi-Fi or perform a dictionary attack.
Some Brother printers (such as the HL-L8360CDW v1.20) were affected by different information disclosure vulnerabilities that provided sensitive information to an unauthenticated user who visits a specific URL.
Anviz access control devices expose credentials (names and passwords) by allowing remote attackers to query this information without credentials via port tcp/5010.