Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function R7WebsSecurityHandler.
Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. After executing set_client_qos, control over the gp register can be obtained.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow.
A vulnerability was found in Tenda AC20 16.03.08.12. This vulnerability affects the function save_virtualser_data of the file /goform/formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function upgrade.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysLogin function.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the bandwidth parameter in the wifiRadioSetIndoor function.
Buffer Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the wpapsk_crypto parameter in the function fromSetWirelessRepeat.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetStaticRouteCfg.
In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode.
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the function set_device_name.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'deviceList' parameter at /goform/setMacFilterCfg.
Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools.
In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability.
In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet.
Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg .
Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetVirtualServerCfg.
Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetNetControlList.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the rebootTime parameter in the sysScheduleRebootSet function.
A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysTimeInfoSet function.
Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the shareSpeed parameter at /goform/WifiGuestSet.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.