Vinchin Backup & Recovery v7.2 was discovered to use default MYSQL credentials.
Vinchin Backup & Recovery v7.2 was discovered to be configured with default root credentials.
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
VinChin Backup & Recovery v5.0.*, v6.0.*, v6.7.*, and v7.0.* was discovered to contain hardcoded credentials.
Vinchin Backup and Recovery 7.2 and Earlier is vulnerable to Authenticated Remote Code Execution (RCE) via the getVerifydiyResult function in ManoeuvreHandler.class.php.
Vinchin Backup & Recovery v7.2 was discovered to contain an authenticated remote code execution (RCE) vulnerability via the deleteUpdateAPK function.
Vinchin Backup & Recovery v7.2 was discovered to contain an authenticated remote code execution (RCE) vulnerability via the setNetworkCardInfo function.
A vulnerability was found in Sangfor Operation and Maintenance Management System up to 3.0.8. This issue affects some unknown processing of the file /isomp-protocol/protocol/getHis of the component HTTP POST Request Handler. The manipulation of the argument sessionPath results in os command injection. The attack may be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
The firmware on Moxa TN-5900 devices through 3.1 allows command injection that could lead to device damage.
A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability classified as critical was found in hzmanyun Education and Training System 3.1.1. Affected by this vulnerability is the function pdf2swf of the file /pdf2swf. The manipulation of the argument file leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was determined in Sangfor Operation and Maintenance Management System up to 3.0.8. Impacted is the function WriterHandle.getCmd of the file /isomp-protocol/protocol/getCmd. This manipulation of the argument sessionPath causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this vulnerability is the function websGetVar of the file /goform/set_cmd. The manipulation of the argument cmd leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function ChgSambaUserSettings. This vulnerability allows attackers to execute arbitrary commands via the samba_name parameter.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R6400v2 before 1.0.4.84, R6700 before 1.0.2.8, R6700v3 before 1.0.4.84, R6900 before 1.0.2.8, and R7900 before 1.0.3.10.
A weakness has been identified in D-Link DIR-806A 100CNb11. Affected is the function ssdpcgi_main of the component SSDP Request Handler. This manipulation causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was identified in Sangfor Operation and Maintenance Management System up to 3.0.8. The affected element is the function SessionController of the file /isomp-protocol/protocol/session. Such manipulation of the argument Hostname leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this issue is the function websGetVar of the file /goform/set_blacklist. The manipulation of the argument mac/enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function proxy_client.asp. This vulnerability allows attackers to execute arbitrary commands via the proxy_srv, proxy_srvport, proxy_lanip, proxy_lanport parameters.
A vulnerability, which was classified as critical, was found in LB-LINK AC1900 Router 1.0.2. Affected is the function websGetVar of the file /goform/set_manpwd. The manipulation of the argument routepwd leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Sangfor Operation and Maintenance Management System up to 3.0.8. This vulnerability affects the function uploadCN of the file VersionController.java. The manipulation of the argument filename leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function version_upgrade.asp. This vulnerability allows attackers to execute arbitrary commands via the path parameter.
An issue was discovered in Titan SpamTitan 7.07. Improper input sanitization of the parameter community on the page snmp-x.php would allow a remote attacker to inject commands into the file snmpd.conf that would allow executing commands on the target server.
Improper Neutralization of Special Elements used in a Command ('Command Injection') in Owl opds 2.2.0.4 allows Command Injection via a crafted network request.
A security flaw has been discovered in Shiguangwu sgwbox N3 2.0.25. Affected is an unknown function of the file /usr/sbin/http_eshell_server of the component DOCKER Feature. Performing manipulation of the argument params results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Shiguangwu sgwbox N3 2.0.25. This impacts an unknown function of the file /usr/sbin/http_eshell_server of the component NETREBOOT Interface. Such manipulation leads to command injection. The attack can be launched remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
The kill-port-process package version < 2.2.0 is vulnerable to a Command Injection vulnerability.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function msp_info.htm. This vulnerability allows attackers to execute arbitrary commands via the cmd parameter.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function urlrd_opt.asp. This vulnerability allows attackers to execute arbitrary commands via the url_en parameter.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function upgrade_filter. This vulnerability allows attackers to execute arbitrary commands via the path and time parameters.
D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the LocalIPAddress parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
A vulnerability was detected in ADSLR B-QE2W401 250814-r037c. Affected by this issue is the function parameterdel_swifimac of the file /send_order.cgi. Performing manipulation of the argument del_swifimac results in command injection. The attack is possible to be carried out remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function wget_test.asp. This vulnerability allows attackers to execute arbitrary commands via the url parameter.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function usb_paswd.asp. This vulnerability allows attackers to execute arbitrary commands via the name parameter.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function uploadPicture. This vulnerability allows attackers to execute arbitrary commands via the pic_name parameter.
A flaw has been found in Edimax BR-6478AC V3 1.0.15. The affected element is the function sub_44CCE4 of the file /boafrm/formSysCmd. This manipulation of the argument sysCmd causes os command injection. The attack may be initiated remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in TOTOLINK X5000R 9.1.0cu.2089_B20211224. Affected by this issue is the function snprintf of the file /cgi-bin/cstecgi.cgi?action=exportOvpn&type=user. This manipulation of the argument User causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
A security vulnerability exists in Zingbox Inspector version 1.293 and earlier, that allows for remote code execution if the Inspector were sent a malicious command from the Zingbox cloud, or if the Zingbox Inspector were tampered with to connect to an attacker's cloud endpoint.
A vulnerability was identified in D-Link DIR-852 1.00. This issue affects some unknown processing of the file /gena.cgi. Such manipulation of the argument service leads to command injection. The attack can be executed remotely. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer.
An issue was discovered in Digi TransPort DR64, SR44 VC74, and WR. The ZING protocol allows arbitrary remote command execution with SUPER privileges. This allows an attacker (with knowledge of the protocol) to execute arbitrary code on the controller including overwriting firmware, adding/removing users, disabling the internal firewall, etc.
TOTOLINK A720R v4.1.5cu.470_B20200911 was discovered to contain a command injection vulnerability in the "Main" function. This vulnerability allows attackers to execute arbitrary commands via the QUERY_STRING parameter.
A security vulnerability has been detected in UTT 进取 750W up to 3.2.2-191225. Affected by this vulnerability is the function system of the file /goform/formPdbUpConfig. Such manipulation of the argument policyNames leads to command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.
D-Link device DIR_878_FW1.30B08_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.64, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RAX120 before 1.2.0.16, RBS50Y before 1.0.0.56, WNR2000v5 before 1.0.0.76, XR450 before 2.3.2.114, XR500 before 2.3.2.114, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, EX6410 before 1.0.0.134, RBR10 before 2.6.1.44, RBR20 before 2.6.2.104, RBR40 before 2.6.2.104, RBR50 before 2.7.2.102, EX6420 before 1.0.0.134, RBS10 before 2.6.1.44, RBS20 before 2.6.2.104, RBS40 before 2.6.2.104, RBS50 before 2.7.2.102, EX6400v2 before 1.0.0.134, RBK12 before 2.6.1.44, RBK20 before 2.6.2.104, RBK40 before 2.6.2.104, and RBK50 before 2.7.2.102.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22.
A command injection vulnerability has been reported to affect QNAP device running QVR. If exploited, this vulnerability could allow remote attackers to run arbitrary commands. We have already fixed this vulnerability in the following versions of QVR: QVR 5.1.5 build 20210902 and later