Vulnerability Details :

CVE-2023-46096

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-14 Nov, 2023 | 11:04
Updated At-08 Jan, 2025 | 16:38
Rejected At-
Credits

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:14 Nov, 2023 | 11:04
Updated At:08 Jan, 2025 | 16:38
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents.

Affected Products
Vendor
Siemens AGSiemens
Product
SIMATIC PCS neo
Default Status
unknown
Versions
Affected
  • All versions < V4.1
Problem Types
TypeCWE IDDescription
CWECWE-306CWE-306: Missing Authentication for Critical Function
Type: CWE
CWE ID: CWE-306
Description: CWE-306: Missing Authentication for Critical Function
Metrics
VersionBase scoreBase severityVector
3.16.5MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:14 Nov, 2023 | 11:15
Updated At:20 Nov, 2023 | 14:26

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.16.5MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Secondary3.16.5MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Type: Primary
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Type: Secondary
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CPE Matches

Siemens AG
siemens
>>simatic_pcs_neo>>Versions before 4.1(exclusive)
cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-306Primaryproductcert@siemens.com
CWE ID: CWE-306
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

60Records found

CVE-2019-10941
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 40.18%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_serverSINEMA Server
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-10919
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-0.60% / 69.35%
||
7 Day CHG-0.02%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_bm_firmwarelogo\!8_bmLOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-32251
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.30% / 53.82%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-21 Apr, 2025 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-31461
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.4||HIGH
EPSS-0.16% / 37.07%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 21:40
Updated-03 Aug, 2024 | 07:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Owl Labs Meeting Owl 5.2.0.15 allows attackers to deactivate the passcode protection mechanism via a certain c 11 message.

Action-Not Available
Vendor-owllabsn/a
Product-meeting_owl_promeeting_owl_pro_firmwaren/a
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-27495
Matching Score-4
Assigner-F5, Inc.
ShareView Details
Matching Score-4
Assigner-F5, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.11% / 29.90%
||
7 Day CHG~0.00%
Published-05 May, 2022 | 16:10
Updated-16 Sep, 2024 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On all versions 1.3.x (fixed in 1.4.0) NGINX Service Mesh control plane endpoints are exposed to the cluster overlay network. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated

Action-Not Available
Vendor-F5, Inc.
Product-nginx_service_meshNGINX Service Mesh
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-34761
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.03% / 7.77%
||
7 Day CHG~0.00%
Published-28 Jun, 2023 | 00:00
Updated-27 Nov, 2024 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unauthenticated attacker within BLE proximity can remotely connect to a 7-Eleven LED Message Cup, Hello Cup 1.3.1 for Android, and bypass the application's client-side chat censor filter.

Action-Not Available
Vendor-7-elevenn/a7-eleven
Product-led_message_cuphello_cupn/aled_message_cup
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-47130
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.57%
||
7 Day CHG~0.00%
Published-26 Sep, 2024 | 17:30
Updated-17 Oct, 2024 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing Authentication for Critical Function in goTenna Pro

The goTenna Pro App allows unauthenticated attackers to remotely update the local public keys used for P2P and group messages. It is advised to update your app to the current release for enhanced encryption protocols.

Action-Not Available
Vendor-gotennagoTennagotenna
Product-gotenna_proPropro_app
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-64307
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.1||HIGH
EPSS-0.04% / 12.23%
||
7 Day CHG-0.00%
Published-14 Nov, 2025 | 23:34
Updated-18 Nov, 2025 | 14:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Brightpick Mission Control / Internal Logic Control Missing Authentication for Critical Function

The Brightpick Internal Logic Control web interface is accessible without requiring user authentication. An unauthorized user could exploit this interface to manipulate robot control functions, including initiating or halting runners, assigning jobs, clearing stations, and deploying storage totes.

Action-Not Available
Vendor-Brightpick AI
Product-Brightpick Mission Control / Internal Logic Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-53847
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-6.2||MEDIUM
EPSS-0.01% / 2.27%
||
7 Day CHG~0.00%
Published-14 Apr, 2026 | 15:38
Updated-17 Apr, 2026 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A missing authentication for critical function vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS 6.4 all versions, FortiOS 6.2.9 through 6.2.17 allows attacker to execute unauthorized code or commands via specially crafted packets.

Action-Not Available
Vendor-Fortinet, Inc.
Product-FortiOS
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6538
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.3||CRITICAL
EPSS-0.22% / 44.67%
||
7 Day CHG~0.00%
Published-25 Mar, 2019 | 21:26
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

Action-Not Available
Vendor-medtronicMedtronic
Product-virtuoso_ii_icdvirtuoso_ii_icd_firmwarecompia_crt-dvisia_af_icd_firmwareclaria_crt-d_firmwareevera_icd_firmwarenayamed_nd_icdmaximo_ii_crt-d_and_lcdmirro_icd_firmwarecarelink_2090_firmwaremycarelink_monitor_firmwareprimo_icd_firmwareconsulta_crt-d_firmwaresecura_icdviva_crt-d_firmwarenayamed_nd_icd_firmwarecarelink_monitormirro_icdvirtuoso_icdconcerto_ii_crt-d_firmwareconcerto_crt-d_firmwaremycarelink_monitorvirtuoso_icd_firmwarevisia_af_icdconcerto_ii_crt-devera_icdcarelink_2090concerto_crt-damplia_crt-dclaria_crt-dmaximo_ii_crt-d_and_lcd_firmwarecarelink_monitor_firmwareprimo_icdprotecta_icd_and_crt-dconsulta_crt-damplia_crt-d_firmwareprotecta_icd_and_crt-d_firmwarecompia_crt-d_firmwareviva_crt-dsecura_icd_firmwareMirro ICDViva CRT-DEvera ICDVirtuoso II ICDAmplia CRT-DNayamed ND ICDClaria CRT-DMirro MRI ICDCareLink MonitorMyCareLink MonitorMaximo II ICDSecura ICDVirtuoso ICDConcerto CRT-DProtecta ICD, Protecta CRT-DCompia CRT-DMaximo II CRT-DVisia AF ICDConcerto II CRT-DCareLink 2090 ProgrammerPrimo ICDConsulta CRT-DConexus Radio Frequency Telemetry ProtocolBrava CRT-D
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-862
Missing Authorization