Authentication Bypass Using an Alternate Path or Channel vulnerability in Drupal Authenticator Login allows Authentication Bypass.This issue affects Authenticator Login: from 0.0.0 before 2.1.4.
A vulnerability of remote credential disclosure was discovered in Advan VD-1 firmware versions up to 230. An attacker can export system configuration which is not encrypted to get the administrator’s account and password in plain text via cgibin/ExportSettings.cgi?Export=1 without any authentication.
Multiple camera devices by UDP Technology, Geutebrück and other vendors allow unauthenticated remote access to sensitive files due to default user authentication settings. This can lead to manipulation of the device and denial of service.
Adobe Framemaker Publishing Server versions 2020.3, 2022.2 and earlier are affected by an Improper Authentication vulnerability that could result in privilege escalation. An attacker could exploit this vulnerability to gain unauthorized access or elevated privileges within the application. Exploitation of this issue does not require user interaction.
Microsoft Exchange Server Elevation of Privilege Vulnerability
On Grandstream GXV3611IR_HD before 1.0.3.23 devices, the root account lacks a password.
There is an arbitrary password modification vulnerability in a D-LINK DSL-2888A router product. An attacker can use this vulnerability to modify the password of the admin user without authorization.
Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network.
admin.php in phpMyBlockchecker 1.0.0055 allows remote attackers to bypass authentication and gain administrative access by setting the PHPMYBCAdmin cookie to LOGGEDIN.
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization.
The ZM Ajax Login & Register plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.0.2. This is due to insufficient verification on the user being supplied during a Facebook login through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the username.
A vulnerability in the Security Assertion Markup Language (SAML) APIs of Cisco Catalyst SD-WAN Manager Software could allow an unauthenticated, remote attacker to gain unauthorized access to the application as an arbitrary user. This vulnerability is due to improper authentication checks for SAML APIs. An attacker could exploit this vulnerability by sending requests directly to the SAML API. A successful exploit could allow the attacker to generate an authorization token sufficient to gain access to the application.
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
The administrator application on ASUS GT-AC2900 devices before 3.0.0.4.386.42643 and Lyra Mini before 3.0.0.4_384_46630 allows authentication bypass when processing remote input from an unauthenticated user, leading to unauthorized access to the administrator interface. This relates to handle_request in router/httpd/httpd.c and auth_check in web_hook.o. An attacker-supplied value of '\0' matches the device's default value of '\0' in some situations. Note: All versions of Lyra Mini and earlier which are unsupported (End-of-Life, EOL) are also affected by this vulnerability, Consumers can mitigate this vulnerability by disabling the remote access features from WAN.
The Plus Addons for Elementor Page Builder WordPress plugin before 4.1.7 was being actively exploited to by malicious actors to bypass authentication, allowing unauthenticated users to log in as any user (including admin) by just providing the related username, as well as create accounts with arbitrary roles, such as admin. These issues can be exploited even if registration is disabled, and the Login widget is not active.
A flaw was found in Red Hat DataGrid 8.x (8.0.0, 8.0.1, 8.1.0 and 8.1.1) and Infinispan (10.0.0 through 12.0.0). An attacker could bypass authentication on all REST endpoints when DIGEST is used as the authentication method. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.
Some Dahua products have access control vulnerability in the password reset process. Attackers can exploit this vulnerability through specific deployments to reset device passwords.
WebITR developed by Uniong has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to log into the system as arbitrary users by exploiting a specific functionality.
The affected product’s configuration is vulnerable due to missing authentication, which may allow an attacker to change configurations and execute arbitrary code on the iView (versions prior to v5.7.03.6182).
Improper access control in PAM vault permissions in Devolutions Server 2024.1.10.0 and earlier allows an authenticated user with access to the PAM to access unauthorized PAM entries via a specific set of permissions.
The identity authentication bypass vulnerability found in some Dahua products during the login process. Attackers can bypass device identity authentication by constructing malicious data packets.
The identity authentication bypass vulnerability found in some Dahua products during the login process. Attackers can bypass device identity authentication by constructing malicious data packets.
cpanel/login.php in EgyPlus 7ammel (aka 7ml) 1.0.1 and earlier sends a redirect to the web browser but does not exit when the supplied credentials are incorrect, which allows remote attackers to bypass authentication by providing arbitrary username and password parameters.
By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions.
DMA Softlab Radius Manager 4.4.0 assigns the same session cookie to every admin session. The cookie is valid when the admin is logged in, but is invalid (temporarily) during times when the admin is logged out. In other words, the cookie is functionally equivalent to a static password, and thus provides permanent access if stolen.
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers access to /webif/SecurityModule to validate the so called and hard coded unique 'eibPort String' which acts as the root SSH key passphrase. This is usable and part of an attack chain to gain SSH root access.
The manage users profile services of the network camera device allows an authenticated. Remote attackers can modify URL parameters and further amend user’s information and escalate privileges to control the devices.
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.
Jupyter Server Proxy allows users to run arbitrary external processes alongside their Jupyter notebook servers and provides authenticated web access. Prior to versions 3.2.3 and 4.1.1, Jupyter Server Proxy did not check user authentication appropriately when proxying websockets, allowing unauthenticated access to anyone who had network access to the Jupyter server endpoint. This vulnerability can allow unauthenticated remote access to any websocket endpoint set up to be accessible via Jupyter Server Proxy. In many cases, this leads to remote unauthenticated arbitrary code execution, due to how affected instances use websockets. The websocket endpoints exposed by `jupyter_server` itself is not affected. Projects that do not rely on websockets are also not affected. Versions 3.2.3 and 4.1.1 contain a fix for this issue.
CWE-287: Improper Authentication may allow Authentication Bypass
This vulnerability allows remote attackers to reset the password of anonymous users without authorization on the affected LG LED Assistant.
Improper authentication vulnerability in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary command with the root privilege via the internet.
Authentication Bypass by Alternate Name vulnerability in DTS Electronics Redline Router firmware allows Authentication Bypass.This issue affects Redline Router: before 7.17.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
Mesa Labs AmegaView Versions 3.0 and prior’s passcode is generated by an easily reversible algorithm, which may allow an attacker to gain access to the device.
Hirschmann HiOS 07.1.01, 07.1.02, and 08.1.00 through 08.5.xx and HiSecOS 03.3.00 through 03.5.01 allow remote attackers to change the credentials of existing users.
An issue was discovered in Veritas Backup Exec before 21.2. It supports multiple authentication schemes: SHA authentication is one of these. This authentication scheme is no longer used in current versions of the product, but hadn't yet been disabled. An attacker could remotely exploit this scheme to gain unauthorized access to an Agent and execute privileged commands.
The N-central server is vulnerable to an authentication bypass of the user interface. This vulnerability is present in all deployments of N-central prior to 2024.2. This vulnerability was discovered through internal N-central source code review and N-able has not observed any exploitation in the wild.
Authentication vulnerability found in Etcd-io v.3.4.10 allows remote attackers to escalate privileges via the debug function.
In versions 8.2.1 through 8.5.2 of Pega Infinity, the password reset functionality for local accounts can be used to bypass local authentication checks.
Hongdian H8922 3.0.5 devices have an undocumented feature that allows access to a shell as a superuser. To connect, the telnet service is used on port 5188 with the default credentials of root:superzxmn.
An improper access control vulnerability has been reported to affect certain legacy versions of HBS 3. If exploited, this vulnerability allows attackers to compromise the security of the operating system.QNAP have already fixed this vulnerability in the following versions of HBS 3: QTS 4.3.6: HBS 3 v3.0.210507 and later QTS 4.3.4: HBS 3 v3.0.210506 and later QTS 4.3.3: HBS 3 v3.0.210506 and later
In Arista's MOS (Metamako Operating System) software which is supported on the 7130 product line, under certain conditions, user authentication can be bypassed when API access is enabled via the JSON-RPC APIs. This issue affects: Arista Metamako Operating System All releases in the MOS-0.1x train MOS-0.13 and post releases in the MOS-0.1x train MOS-0.26.6 and below releases in the MOS-0.2x train MOS-0.31.1 and below releases in the MOS-0.3x train
The impact of this vulnerability is that Arista's EOS eAPI may skip re-evaluating user credentials when certificate based authentication is used, which allows remote attackers to access the device via eAPI.
This vulnerability exists in GajShield Data Security Firewall firmware versions prior to v4.28 (except v4.21) due to insecure default credentials which allows remote attacker to login as superuser by using default username/password via web-based management interface and/or exposed SSH port thereby enabling remote attackers to execute arbitrary commands with administrative/superuser privileges on the targeted systems. The vulnerability has been addressed by forcing the user to change their default password to a new non-default password.
A request-validation issue was discovered in Open5GS 2.1.3 through 2.2.x before 2.2.1. The WebUI component allows an unauthenticated user to use a crafted HTTP API request to create, read, update, or delete entries in the subscriber database. For example, new administrative users can be added. The issue occurs because Express is not set up to require authentication.
Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules). This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization. This issue affects B&R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34.6, from 4.4* through 4.45.1, from 4.5* through 4.45.3, from 4.7* through 4.72.9.
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
A vulnerability was found in SourceCodester Online Pizza Ordering System 1.0. It has been classified as critical. This affects an unknown part of the file admin/ajax.php?action=save_user of the component Password Change Handler. The manipulation leads to improper authentication. It is possible to initiate the attack remotely. The identifier VDB-223305 was assigned to this vulnerability.