In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges.
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
Delta Electronics DTN Soft version 2.0.1 and prior are vulnerable to an attacker achieving remote code execution through a deserialization of untrusted data vulnerability.
A Blind SQL injection vulnerability exists in the /DataHandler/AM/AM_Handler.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter type before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
Delta Electronics DIAView has multiple vulnerabilities.
Delta Electronics DIAView has multiple vulnerabilities.
A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
DIAView (v4.2.0 and prior) - Directory Traversal Information Disclosure Vulnerability
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing ISP file.
Delta Industrial Automation CNCSoft ScreenEditor Versions 1.01.28 (with ScreenEditor Version 1.01.2) and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
Delta Electronics COMMGR v1 and v2 uses insufficiently randomized values to generate session IDs (CWE-338). An attacker could easily brute force a session ID and load and execute arbitrary code.
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field
An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product.
The Delta Electronics DVW-W02W2-E2 devices expose a web administration interface to users. This interface implements multiple features that are affected by command injections and stack overflows vulnerabilities. Successful exploitation of these flaws would allow remote unauthenticated attackers to gain remote code execution with elevated privileges on the affected devices. This issue affects DVW-W02W2-E2 through version 2.5.2.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to leverage debugging logic to execute arbitrary code when parsing CBDGL file.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file.
DVP-12SE11T - Out-of-bound memory write Vulnerability
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing ISP file.
In Delta Electronics Automation TPEditor version 1.89 or prior, parsing a malformed program file may cause heap-based buffer overflow vulnerability, which may allow remote code execution.
DVP-12SE11T - Password Protection Bypass
Delta Electronics AS320T has denial of service via the undocumented subfunction vulnerability.
Delta Electronics AS320T has No checking of the length of the buffer with the file name vulnerability.
ASDA-Soft Stack-based Buffer Overflow Vulnerability
Delta Electronics DVP12SE PLCs are susceptible to a resource allocation vulnerability without limits or throttling (CWE-770) within their Modbus TCP service.
Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions.
Delta Electronics COMMGR2 has Stack-based Buffer Overflow vulnerability.
SQL injection vulnerability exists in GetDIAE_usListParameters.
Delta Industrial Automation COMMGR Versions 1.12 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute remote code.
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics AS320T has incorrect calculation of the buffer size on the stack in the GET/PUT request handler of the web service.
Delta Electronics AS320T has no checking of the length of the buffer with the directory name vulnerability.
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass.
Delta Electronics DIAView has Command Injection vulnerability.
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.