Nest is a framework for building scalable Node.js server-side applications. In versions 0.2.0 and below, a critical Remote Code Execution (RCE) vulnerability was discovered in the @nestjs/devtools-integration package. When enabled, the package exposes a local development HTTP server with an API endpoint that uses an unsafe JavaScript sandbox (safe-eval-like implementation). Due to improper sandboxing and missing cross-origin protections, any malicious website visited by a developer can execute arbitrary code on their local machine. The package adds HTTP endpoints to a locally running NestJS development server. One of these endpoints, /inspector/graph/interact, accepts JSON input containing a code field and executes the provided code in a Node.js vm.runInNewContext sandbox. This is fixed in version 0.2.1.
TP-Link TL-WR841N ated_tp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link TL-WR841N routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ated_tp service. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21825.
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DVA-2800 and DSL-2888A routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the dhttpd service, which listens on TCP port 8008 by default. When parsing the path parameter, the process does not properly validate a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the web server. Was ZDI-CAN-10911.
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DAP-1860 firmware version 1.04B03 WiFi extenders. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the Authorization request header, the process does not properly validate a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10880.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.3.110, SRR60 before 2.5.3.110, and SRS60 before 2.5.3.110.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.58 and R7500v2 before 1.0.3.48.
NETGEAR R8300 devices before 1.0.2.134 are affected by command injection by an unauthenticated attacker.
D-Link DI_8004W 16.07.26A1 contains a command execution vulnerability in jhttpd msp_info_htm function.
DrayTek Vigor3900 1.5.1.3 allows attackers to inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the sign_cacertificate function.
Command Injection vulnerability in D-Link Dir 882 with firmware version DIR882A1_FW130B06 allows attackers to run arbitrary commands via crafted POST request to /HNAP1/.
A vulnerability was discovered in DI_8200-16.07.26A1, which has been classified as critical. This issue affects the upgrade_filter_asp function in the upgrade_filter.asp file. Manipulation of the path parameter can lead to command injection.
A malicious user on the same LAN could use DNS spoofing followed by a command injection attack to trick a NAS device into loading through an unsecured HTTP call. Addressed this vulnerability by disabling checks for internet connectivity using HTTP.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2.
A command injection vulnerability exists in the cgibin binary in DIR-845L router firmware <= v1.01KRb03.
HGW BL1500HM Ver 002.001.013 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary command.
FusionSphere OpenStack with software V100R006C00 and V100R006C10RC2 has two command injection vulnerabilities due to the insufficient input validation on one port. An attacker can exploit the vulnerabilities to gain root privileges by sending some messages with malicious commands.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.
Wuhan Tianyu Information Industry Co., Ltd Tianyu CPE Router CommonCPExCPETS_v3.2.468.11.04_P4 was discovered to contain a command injection vulnerability via the component at_command.asp.
Shenzhen Tuoshi Network Communications Co.,Ltd 5G CPE Router NR500-EA RG500UEAABxCOMSLICv3.2.2543.12.18 was discovered to contain a command injection vulnerability via the component at_command.asp.
Tenda FH451 v1.0.0.9 has a command injection vulnerability in the formexeCommand function i
D-Link DI_8004W 16.07.26A1 contains a command execution vulnerability in the jhttpd upgrade_filter_asp function.
D-Link DI-7003GV2 v24.04.18D1, DI-7100G+V2 v24.04.18D1, DI-7100GV2 v24.04.18D1, DI-7200GV2 v24.04.18E1, DI-7300G+V2 v24.04.18D1, and DI-7400G+V2 v24.04.18D1 are vulnerable to Remote Command Execution due to insufficient parameter filtering in the CGI handling function of upgrade_filter.asp.
D-Link DI-7003G v19.12.24A1, DI-7003GV2 v24.04.18D1, DI-7100G+V2 v24.04.18D1, DI-7100GV2 v24.04.18D1, DI-7200GV2 v24.04.18E1, DI-7300G+V2 v24.04.18D1, and DI-7400G+V2 v24.04.18D1 are vulnerable to Remote Command Execution (RCE) via version_upgrade.asp.