The devices allow access to an unprotected endpoint that allows MPFS file system binary image upload without authentication. The MPFS2 file system module provides a light-weight read-only file system that can be stored in external EEPROM, external serial flash, or internal flash program memory. This file system serves as the basis for the HTTP2 web server module, but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
Hydra is a continuous integration service for Nix based projects. Prior to commit f7bda02, /api/push-github and /api/push-gitea are called by the corresponding forge without HTTP Basic authentication. Both forges do however feature HMAC signing with a secret key. Triggering an evaluation can be very taxing on the infrastructure when large evaluations are done, introducing potential denial of service attacks on the host running the evaluator. This issue has been patched by commit f7bda02. A workaround involves blocking /api/push-github and /api/push-gitea via a reverse proxy.
An issue was discovered in Emote Remote Mouse through 3.015. Attackers can close any running process by sending the process name in a specially crafted packet. This information is sent in cleartext and is not protected by any authentication logic.
A vulnerability has been found in TOTOLINK A720R 4.1.5cu.374 and classified as critical. This vulnerability affects unknown code of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument topicurl with the input RebootSystem leads to missing authentication. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
A vulnerability in the web-based management interface of Cisco RV110W, RV130W, and RV215W Routers could allow an unauthenticated, remote attacker to disconnect clients that are connected to the guest network on an affected router. The vulnerability is due to improper authorization of an HTTP request. An attacker could exploit this vulnerability by accessing the URL for device disconnection and providing the connected device information. A successful exploit could allow the attacker to deny service to specific clients that are connected to the guest network.