CVE-2024-2977

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Mar, 2024 | 13:31
Updated At-12 Aug, 2024 | 15:44
Rejected At-
Credits

Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Mar, 2024 | 13:31
Updated At:12 Aug, 2024 | 15:44
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
F1203
Versions
Affected
  • 2.0.1.6
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
wxhwxhwxh_tutu (VulDB User)
Timeline
EventDate
Advisory disclosed2024-03-27 00:00:00
VulDB entry created2024-03-27 01:00:00
VulDB entry last update2024-03-27 08:09:59
Event: Advisory disclosed
Date: 2024-03-27 00:00:00
Event: VulDB entry created
Date: 2024-03-27 01:00:00
Event: VulDB entry last update
Date: 2024-03-27 08:09:59
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.258146
vdb-entry
technical-description
https://vuldb.com/?ctiid.258146
signature
permissions-required
https://vuldb.com/?submit.301028
third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md
exploit
Hyperlink: https://vuldb.com/?id.258146
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.258146
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.301028
Resource:
third-party-advisory
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md
Resource:
exploit
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.258146
vdb-entry
technical-description
x_transferred
https://vuldb.com/?ctiid.258146
signature
permissions-required
x_transferred
https://vuldb.com/?submit.301028
third-party-advisory
x_transferred
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md
exploit
x_transferred
Hyperlink: https://vuldb.com/?id.258146
Resource:
vdb-entry
technical-description
x_transferred
Hyperlink: https://vuldb.com/?ctiid.258146
Resource:
signature
permissions-required
x_transferred
Hyperlink: https://vuldb.com/?submit.301028
Resource:
third-party-advisory
x_transferred
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md
Resource:
exploit
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Vendor
Tenda Technology Co., Ltd.tenda
Product
fh1203_firmware
CPEs
  • cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 2.0.1.6
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Mar, 2024 | 14:15
Updated At:15 Jan, 2025 | 18:19

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>f1203_firmware>>2.0.1.6
cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>f1203>>-
cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-121Secondarycna@vuldb.com
CWE-787Primarynvd@nist.gov
CWE ID: CWE-121
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.258146cna@vuldb.com
Permissions Required
Third Party Advisory
VDB Entry
https://vuldb.com/?id.258146cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.301028cna@vuldb.com
Third Party Advisory
VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.mdaf854a3a-2127-422b-91ae-364da2661108
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.258146af854a3a-2127-422b-91ae-364da2661108
Permissions Required
Third Party Advisory
VDB Entry
https://vuldb.com/?id.258146af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.301028af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
VDB Entry
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.258146
Source: cna@vuldb.com
Resource:
Permissions Required
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?id.258146
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.301028
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.258146
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Permissions Required
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?id.258146
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.301028
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
VDB Entry

Change History

0
Information is not available yet

Similar CVEs

1529Records found

CVE-2024-4117
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.26%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelPortMapping formDelPortMapping stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4120
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 17:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4124
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.31%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5619
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.40%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 23:00
Updated-06 Jun, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 addUserName formaddUserName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4122
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3882
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.55%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E fromRouteStatic stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3906
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.50% / 64.96%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 10:31
Updated-21 Jan, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3876
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.04%
||
7 Day CHG-0.21%
Published-16 Apr, 2024 | 18:00
Updated-21 Jan, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3910
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.09%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3907
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.65% / 69.75%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:00
Updated-17 Jan, 2025 | 21:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3879
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.37%
||
7 Day CHG-0.06%
Published-16 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3874
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.28% / 50.91%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 15:31
Updated-01 Aug, 2024 | 20:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-W20Ew20e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3878
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.51% / 65.43%
||
7 Day CHG-0.21%
Published-16 Apr, 2024 | 18:31
Updated-21 Jan, 2025 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3875
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.74% / 72.06%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 18:00
Updated-21 Jan, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 Natlimit fromNatlimit stack-based overflow

A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6111
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.40%
||
7 Day CHG+0.01%
Published-16 Jun, 2025 | 07:00
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5527
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.72%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 20:31
Updated-09 Jun, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow

A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-45781
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.17%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 00:00
Updated-03 Sep, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1803_firmwareax1803n/aax1803_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-32299
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.09%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1203fh1203_firmwaren/afh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32305
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.59%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-06 Nov, 2024 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/aa18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3011
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 60.91%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3006
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.70%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 22:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3007
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.70%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-15 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2993
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.84%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3008
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.70%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-08 Apr, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2984
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.72%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-14 Jan, 2025 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2852
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.77%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 04:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2893
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.28%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2850
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.56%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2981
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.92%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 15:00
Updated-14 Jan, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2987
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 71.62%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2892
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.79%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:00
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2988
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.38%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:31
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2989
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.97%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2979
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.11%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2978
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.11%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-10 Apr, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 setcfm formSetCfm stack-based overflow

A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2895
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.12%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:31
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2856
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.93%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 06:31
Updated-21 Aug, 2024 | 15:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2899
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.11%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:00
Updated-10 Apr, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2902
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.72%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2986
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.12%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:31
Updated-14 Jan, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2985
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.19%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:31
Updated-14 Jan, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2807
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.97%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-10 Apr, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2709
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.56%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2809
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.65% / 69.98%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-01 Aug, 2024 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2806
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 67.90%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2764
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.70%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2763
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.69%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2814
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.84%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:00
Updated-08 Aug, 2024 | 20:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2711
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.77%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U addWifiMacFilter stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2815
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.38%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 30
  • 31
  • Next
Details not found