A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been classified as critical. This affects the function fromSpeedTestSet of the file /goform/setRateTest of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been declared as critical. This vulnerability affects the function formWifiBasicSet of the file /goform/setWrlBasicInfo of the component httpd. The manipulation of the argument extChannel leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda O3V2 1.0.0.12(3880). Affected is the function setAutoReboot of the file /goform/setNetworkService of the component httpd. The manipulation of the argument week leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Tenda AC6 V15.03.05.16 was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). Affected by this vulnerability is the function formWifiMacFilterSet of the file /goform/setWrlFilterList of the component httpd. The manipulation of the argument macList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been classified as critical. This affects the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Tenda AC6 V15.03.06.23_multi has a stack overflow vulnerability via the deviceName parameter in the saveParentControlInfo function.
A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda AC6 V15.03.06.23_multi is vulnerable to Buffer Overflow in the function formSetMacFilterCfg via the parameters macFilterType and deviceList.
A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Tenda AC6 V15.03.06.23_multi is vulnerable to Buffer Overflow in the formSetCfm function.
Tenda AC6 V15.03.06.23_multi was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function.
A buffer overflow vulnerability exists in the fromNatStaticSetting function of Tenda AC6 <=V15.03.05.19 via the page parameter.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function.
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function.
A stack-based buffer overflow vulnerability exists in the Cloud API functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted HTTP response can lead to arbitrary code execution. An attacker can send an HTTP response to trigger this vulnerability.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Tenda FH451 V1.0.0.9 has a stack overflow vulnerability in the function.frmL7ImForm.
In Tenda RX3 V1.0br_V16.03.13.11 in the GetParentControlInfo function of the web url /goform/GetParentControlInfo, the manipulation of the parameter mac leads to stack overflow.
A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda FH451 V1.0.0.9 has a stack overflow vulnerability in the function.P2pListFilter.
In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution.