Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-34942

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-10 May, 2024 | 12:52
Updated At-13 Feb, 2025 | 15:53
Rejected At-
Credits

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:10 May, 2024 | 12:52
Updated At:13 Feb, 2025 | 15:53
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0
N/A
Hyperlink: https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Vendor
Tenda Technology Co., Ltd.tenda
Product
fh1206_firmware
CPEs
  • cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\(8155\)_en:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 1.2.0.8\(8155\)_en
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0
x_transferred
Hyperlink: https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:14 May, 2024 | 15:39
Updated At:04 Apr, 2025 | 14:46

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>fh1206_firmware>>1.2.0.8\(8155\)_en
cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\(8155\)_en:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>fh1206>>-
cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-121Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-121
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0cve@mitre.org
Exploit
Third Party Advisory
https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0af854a3a-2127-422b-91ae-364da2661108
Exploit
Third Party Advisory
Hyperlink: https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Hyperlink: https://palm-vertebra-fe9.notion.site/formexeCommand-200db77a90d34c708b903c935c7c65c0
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

918Records found

CVE-2024-2987
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 72.10%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2994
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.86%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3011
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.22%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2977
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 66.36%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2989
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.21%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3012
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.22%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2815
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.86%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2807
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.59%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-10 Apr, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2850
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.80%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2814
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.00%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:00
Updated-08 Aug, 2024 | 20:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2894
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.68%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:00
Updated-22 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetNetControlList formSetQosBand stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2808
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.64%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:00
Updated-12 Aug, 2024 | 13:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 QuickIndex formQuickIndex stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2809
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 72.10%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-01 Aug, 2024 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2903
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.72%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:31
Updated-22 Jan, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2898
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.63%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2852
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.09%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 04:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2805
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.67%
||
7 Day CHG-0.04%
Published-22 Mar, 2024 | 03:00
Updated-24 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2895
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.63%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:31
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2901
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.68%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2892
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.54%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:00
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2893
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.18%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2704
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.32%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:00
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2710
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 46.66%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U openSchedWifi setSchedWifi stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2705
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.48% / 64.54%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2764
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.73%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2711
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 46.66%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U addWifiMacFilter stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2708
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.01%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2581
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 69.18%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-8810
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.76%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 13:02
Updated-14 Aug, 2025 | 16:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 SetFirewallCfg strcpy stack-based overflow

A vulnerability classified as critical was found in Tenda AC20 16.03.08.05. Affected by this vulnerability is the function strcpy of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7796
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.39%
||
7 Day CHG~0.00%
Published-18 Jul, 2025 | 17:32
Updated-23 Jul, 2025 | 16:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 PPTPDClient fromPptpUserAdd stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451_firmwarefh451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7417
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.25%
||
7 Day CHG-0.02%
Published-10 Jul, 2025 | 22:02
Updated-16 Jul, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet stack-based overflow

A vulnerability has been found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this vulnerability is the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument ip leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2180
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 22.67%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 19:32
Updated-10 Feb, 2026 | 14:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 fast_setting_wifi_set stack-based overflow

A vulnerability was identified in Tenda RX3 16.03.13.11. Affected is an unknown function of the file /goform/fast_setting_wifi_set. Such manipulation of the argument ssid_5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2187
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 22.67%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 21:02
Updated-10 Feb, 2026 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow

A vulnerability was found in Tenda RX3 16.03.13.11. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7855
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 34.96%
||
7 Day CHG~0.00%
Published-19 Jul, 2025 | 21:02
Updated-23 Jul, 2025 | 16:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 qossetting fromqossetting stack-based overflow

A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451_firmwarefh451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-10130
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.79% / 73.41%
||
7 Day CHG~0.00%
Published-18 Oct, 2024 | 21:31
Updated-28 Oct, 2024 | 16:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2181
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 22.67%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 19:32
Updated-10 Feb, 2026 | 14:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 openSchedWifi stack-based overflow

A security flaw has been discovered in Tenda RX3 16.03.13.11. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2185
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.03% / 7.17%
||
7 Day CHG-0.05%
Published-08 Feb, 2026 | 20:32
Updated-10 Feb, 2026 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow

A flaw has been found in Tenda RX3 16.03.13.11. This issue affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. This manipulation of the argument devName/mac causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2186
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 22.67%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 21:02
Updated-10 Feb, 2026 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow

A vulnerability has been found in Tenda RX3 16.03.13.11. Impacted is the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument list leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11248
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.00% / 76.57%
||
7 Day CHG~0.00%
Published-15 Nov, 2024 | 17:00
Updated-19 Nov, 2024 | 21:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11061
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.30% / 53.20%
||
7 Day CHG~0.00%
Published-11 Nov, 2024 | 00:31
Updated-13 Nov, 2024 | 23:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow

A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-1637
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.03% / 7.80%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 22:32
Updated-10 Feb, 2026 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow

A vulnerability was identified in Tenda AC21 16.03.08.16. The affected element is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21_firmwareac21AC21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11745
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.19% / 40.77%
||
7 Day CHG~0.00%
Published-26 Nov, 2024 | 21:00
Updated-03 Dec, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-11056
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.12%
||
7 Day CHG~0.00%
Published-10 Nov, 2024 | 16:31
Updated-14 Nov, 2024 | 15:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-10283
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.50%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 15:00
Updated-01 Nov, 2024 | 14:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-1329
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.20%
||
7 Day CHG~0.00%
Published-22 Jan, 2026 | 14:32
Updated-03 Feb, 2026 | 13:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1803 WifiGuestSet fromGetWifiGuestBasic stack-based overflow

A flaw has been found in Tenda AX1803 1.0.0.1. The affected element is the function fromGetWifiGuestBasic of the file /goform/WifiGuestSet. Executing a manipulation of the argument guestWrlPwd/guestEn/guestSsid/hideSsid/guestSecurity can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1803ax1803_firmwareAX1803
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-10281
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.50%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:00
Updated-01 Nov, 2024 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow

A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10698
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.41% / 80.22%
||
7 Day CHG~0.00%
Published-02 Nov, 2024 | 13:31
Updated-05 Nov, 2024 | 15:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6ac6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10351
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 62.59%
||
7 Day CHG~0.00%
Published-24 Oct, 2024 | 23:31
Updated-01 Nov, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow

A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9 Prorx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10662
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.61% / 69.29%
||
7 Day CHG~0.00%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10434
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.12%
||
7 Day CHG~0.00%
Published-28 Oct, 2024 | 00:31
Updated-01 Nov, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow

A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 18
  • 19
  • Next
Details not found