Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-39373

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-27 Jun, 2024 | 15:59
Updated At-02 Aug, 2024 | 04:26
Rejected At-
Credits

Improper Neutralization of Special Elements used in a Command in TELSAT marKoni FM Transmitter

TELSAT marKoni FM Transmitters are vulnerable to a command injection vulnerability through the manipulation of settings and could allow an attacker to gain unauthorized access to the system with administrative privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:27 Jun, 2024 | 15:59
Updated At:02 Aug, 2024 | 04:26
Rejected At:
▼CVE Numbering Authority (CNA)
Improper Neutralization of Special Elements used in a Command in TELSAT marKoni FM Transmitter

TELSAT marKoni FM Transmitters are vulnerable to a command injection vulnerability through the manipulation of settings and could allow an attacker to gain unauthorized access to the system with administrative privileges.

Affected Products
Vendor
marKoni
Product
Markoni-D (Compact) FM Transmitters
Default Status
unaffected
Versions
Affected
  • From 0 before 2.0.1 (custom)
Vendor
marKoni
Product
Markoni-DH (Exciter+Amplifiers) FM Transmitters
Default Status
unaffected
Versions
Affected
  • From 0 before 2.0.1 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
4.09.3CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 4.0
Base score: 9.3
Base severity: CRITICAL
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Markoni has released the following version to remediate these vulnerabilities: TELSAT marKoni FM Transmitter: Version 2.0.1. For more information, contact Markoni https://www.markoni.it/contacts/ .

Configurations

Workarounds

Exploits

Credits

finder
CISA discovered a public Proof of Concept (PoC) as authored by Gjoko Krstic and reported it to marKoni.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-24-179-01
government-resource
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-24-179-01
Resource:
government-resource
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Vendor
markoni
Product
markoni-d_fm_transmitter
CPEs
  • cpe:2.3:a:markoni:markoni-d_fm_transmitter:*:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • From 0 before 2.0.1 (custom)
Vendor
markoni
Product
markoni-dh_fm_transmitter
CPEs
  • cpe:2.3:a:markoni:markoni-dh_fm_transmitter:*:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • From 0 before 2.0.1 (custom)
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-24-179-01
government-resource
x_transferred
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-24-179-01
Resource:
government-resource
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:27 Jun, 2024 | 16:15
Updated At:17 Sep, 2024 | 18:26

TELSAT marKoni FM Transmitters are vulnerable to a command injection vulnerability through the manipulation of settings and could allow an attacker to gain unauthorized access to the system with administrative privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.09.3CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.17.2HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 9.3
Base severity: CRITICAL
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CPE Matches

markoni
markoni
>>markoni-d_\(compact\)_firmware>>Versions before 2.0.1(exclusive)
cpe:2.3:o:markoni:markoni-d_\(compact\)_firmware:*:*:*:*:*:*:*:*
markoni
markoni
>>markoni-d_\(compact\)>>-
cpe:2.3:h:markoni:markoni-d_\(compact\):-:*:*:*:*:*:*:*
markoni
markoni
>>markoni-dh_\(exciter\+amplifiers\)_firmware>>Versions before 2.0.1(exclusive)
cpe:2.3:o:markoni:markoni-dh_\(exciter\+amplifiers\)_firmware:*:*:*:*:*:*:*:*
markoni
markoni
>>markoni-dh_\(exciter\+amplifiers\)>>-
cpe:2.3:h:markoni:markoni-dh_\(exciter\+amplifiers\):-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primaryics-cert@hq.dhs.gov
CWE ID: CWE-77
Type: Primary
Source: ics-cert@hq.dhs.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.cisa.gov/news-events/ics-advisories/icsa-24-179-01ics-cert@hq.dhs.gov
Third Party Advisory
US Government Resource
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-24-179-01
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

290Records found

CVE-2024-39376
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.3||CRITICAL
EPSS-0.11% / 30.72%
||
7 Day CHG~0.00%
Published-27 Jun, 2024 | 16:13
Updated-17 Sep, 2024 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Improper Access Control In TELSAT MarKoni FM Transmitter

TELSAT marKoni FM Transmitters are vulnerable to users gaining unauthorized access to sensitive information or performing actions beyond their designated permissions.

Action-Not Available
Vendor-markonimarKonimarkoni
Product-markoni-dh_\(exciter\+amplifiers\)_firmwaremarkoni-d_\(compact\)_firmwaremarkoni-dh_\(exciter\+amplifiers\)markoni-d_\(compact\)Markoni-D (Compact) FM TransmittersMarkoni-DH (Exciter+Amplifiers) FM Transmittersmarkoni-dh_fm_transmittermarkoni-d_fm_transmitter
CWE ID-CWE-284
Improper Access Control
CVE-2024-39374
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.3||CRITICAL
EPSS-0.15% / 36.33%
||
7 Day CHG~0.00%
Published-27 Jun, 2024 | 16:03
Updated-17 Sep, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Use of Hard-coded Credentials in TELSAT marKoni FM Transmitter

TELSAT marKoni FM Transmitters are vulnerable to an attacker exploiting a hidden admin account that can be accessed through the use of hard-coded credentials.

Action-Not Available
Vendor-markonimarKonimarkoni
Product-markoni-dh_\(exciter\+amplifiers\)_firmwaremarkoni-d_\(compact\)_firmwaremarkoni-dh_\(exciter\+amplifiers\)markoni-d_\(compact\)Markoni-D (Compact) FM TransmittersMarkoni-DH (Exciter+Amplifiers) FM Transmittersmarkoni-dh_fm_transmittermarkoni-d_fm_transmitter
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-39375
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.3||CRITICAL
EPSS-0.02% / 3.38%
||
7 Day CHG~0.00%
Published-27 Jun, 2024 | 16:07
Updated-17 Sep, 2024 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Use of Client-Side Authentication in TELSAT marKoni FM Transmitter

TELSAT marKoni FM Transmitters are vulnerable to an attacker bypassing authentication and gaining administrator privileges.

Action-Not Available
Vendor-markonimarKoni
Product-markoni-dh_\(exciter\+amplifiers\)_firmwaremarkoni-d_\(compact\)_firmwaremarkoni-dh_\(exciter\+amplifiers\)markoni-d_\(compact\)Markoni-D (Compact) FM TransmittersMarkoni-DH (Exciter+Amplifiers) FM Transmitters
CWE ID-CWE-603
Use of Client-Side Authentication
CVE-2023-20865
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-7.2||HIGH
EPSS-0.50% / 64.71%
||
7 Day CHG~0.00%
Published-20 Apr, 2023 | 00:00
Updated-05 Feb, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Aria Operations for Logs contains a command injection vulnerability. A malicious actor with administrative privileges in VMware Aria Operations for Logs can execute arbitrary commands as root.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-aria_operations_for_logscloud_foundationVMware Aria Operations for Logs (formerly vRealize Log Insight)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20219
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-0.45% / 62.61%
||
7 Day CHG~0.00%
Published-01 Nov, 2023 | 17:08
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple vulnerabilities in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The attacker would need valid device credentials but does not require administrator privileges to exploit this vulnerability. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device including the underlying operating system which could also affect the availability of the device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centerCisco Firepower Management Centerfirepower_management_center
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20045
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-4.9||MEDIUM
EPSS-0.04% / 11.99%
||
7 Day CHG~0.00%
Published-19 Jan, 2023 | 01:39
Updated-02 Aug, 2024 | 08:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based management interface of Cisco Small Business RV160 and RV260 Series VPN Routers could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system of an affected device. This vulnerability is due to insufficient validation of user input. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary commands using root-level privileges on the affected device. To exploit this vulnerability, the attacker must have valid Administrator-level credentials on the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv160_vpn_routerrv160w_wireless-ac_vpn_routerrv160_vpn_router_firmwarerv260p_vpn_router_with_poerv160w_wireless-ac_vpn_router_firmwarerv260_vpn_routerrv260_vpn_router_firmwarerv260p_vpn_router_with_poe_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2023-20209
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-30.12% / 96.50%
||
7 Day CHG-1.11%
Published-16 Aug, 2023 | 20:59
Updated-23 Oct, 2024 | 19:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based management interface of Cisco Expressway Series and Cisco TelePresence Video Communication Server (VCS) could allow an authenticated, remote attacker with read-write privileges on the application to perform a command injection attack that could result in remote code execution on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to establish a remote shell with root privileges.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-telepresence_video_communication_serverCisco TelePresence Video Communication Server (VCS) Expressway
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38520
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.6||MEDIUM
EPSS-0.26% / 49.20%
||
7 Day CHG-0.10%
Published-11 Aug, 2021 | 00:02
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R6400 before 1.0.1.52, R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, and R7000P before 1.3.2.124.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r6900_firmwarer6700r6400r6400_firmwarer6700_firmwarer6900r7000pr7000p_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20026
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.40% / 59.57%
||
7 Day CHG~0.00%
Published-19 Jan, 2023 | 01:33
Updated-12 Mar, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based management interface of Cisco Small Business RV016, RV042, RV042G, RV082, RV320 and RV325 Routers could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. This vulnerability is due to improper validation of user input within incoming HTTP packets. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface. A successful exploit could allow the attacker to gain root-level privileges and access unauthorized data. To exploit this vulnerability, an attacker would need to have valid administrative credentials on the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv042_firmwarerv042grv042rv016rv082rv042g_firmwarerv016_firmwarerv082_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20124
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.05% / 14.87%
||
7 Day CHG~0.00%
Published-05 Apr, 2023 | 00:00
Updated-28 Oct, 2024 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV016, RV042, RV042G, RV082, RV320, and RV325 Routers Remote Command Execution Vulnerability

A vulnerability in the web-based management interface of Cisco Small Business RV016, RV042, RV042G, RV082, RV320, and RV325 Routers could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. This vulnerability is due to improper validation of user input within incoming HTTP packets. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface. A successful exploit could allow the attacker to gain root-level privileges and access unauthorized data. To exploit this vulnerability, an attacker would need to have valid administrative credentials on the affected device. Cisco has not released software updates that address this vulnerability.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20220
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-0.37% / 57.79%
||
7 Day CHG~0.00%
Published-01 Nov, 2023 | 17:09
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. To exploit these vulnerabilities, the attacker must have valid device credentials, but does not need Administrator privileges. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device, including on the underlying operating system, which could also affect the availability of the device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centerCisco Firepower Management Centerfirepower_management_center
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20118
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-2.09% / 83.31%
||
7 Day CHG+0.05%
Published-05 Apr, 2023 | 16:05
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-03-24||Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

A vulnerability in the web-based management interface of Cisco Small Business Routers RV016, RV042, RV042G, RV082, RV320, and RV325 Routers could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. This vulnerability is due to improper validation of user input within incoming HTTP packets. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface. A successful exploit could allow the attacker to gain root-level privileges and access unauthorized data. To exploit this vulnerability, an attacker would need to have valid administrative credentials on the affected device. Cisco has not and will not release software updates that address this vulnerability. However, administrators may disable the affected feature as described in the Workarounds ["#workarounds"] section. {{value}} ["%7b%7bvalue%7d%7d"])}]]

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv042_firmwarerv325rv320rv016_firmwarerv082rv042grv016rv082_firmwarerv325_firmwarerv042g_firmwarerv320_firmwarerv042Cisco Small Business RV Series Router FirmwareSmall Business RV Series Routers
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1457
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.16% / 37.57%
||
7 Day CHG~0.00%
Published-25 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgerouter_x_firmwareedgerouter_xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7553
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.09% / 27.20%
||
7 Day CHG+0.03%
Published-13 Jul, 2025 | 23:44
Updated-18 Jul, 2025 | 13:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-818LW System Time Page os command injection

A vulnerability classified as critical has been found in D-Link DIR-818LW up to 20191215. This affects an unknown part of the component System Time Page. The manipulation of the argument NTP Server leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818lwdir-818lw_firmwareDIR-818LW
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38120
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
ShareView Details
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
CVSS Score-5.1||MEDIUM
EPSS-0.18% / 40.13%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 06:28
Updated-13 Sep, 2024 | 18:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Remote Code Execution using Bash command Injection in backup scheduling functionality in NetIQ Advance Authentication

A vulnerability identified in Advance Authentication that allows bash command Injection in administrative controlled functionality of backup due to improper handling in provided command parameters. This issue affects NetIQ Advance Authentication version before 6.3.5.1.

Action-Not Available
Vendor-Micro Focus International LimitedOpen Text Corporation
Product-netiq_advanced_authenticationNetIQ Advance Authentication
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1456
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.15% / 35.68%
||
7 Day CHG~0.00%
Published-25 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgerouter_x_firmwareedgerouter_xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1168
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-1.49% / 80.28%
||
7 Day CHG~0.00%
Published-21 Mar, 2023 | 20:22
Updated-26 Feb, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Remote Code Execution in Aruba CX Switches

An authenticated remote code execution vulnerability exists in the AOS-CX Network Analytics Engine. Successful exploitation of this vulnerability results in the ability to execute arbitrary code as a privileged user on the underlying operating system, leading to a complete compromise of the switch running AOS-CX.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)
Product-aruba_cx_6200m_24garuba_cx_8325-32caruba_cx_6300m_48garuba_cx_8360-48y6caruba_cx_8360-12caruba_cx_10000-48y6aruba_cx_8400aruba_cx_6300m_24paruba_cx_6410aruba_cx_8360-16y2caruba_cx_8320-32aruba_cx_9300_32daruba_cx_6200f_48garubaos-cxaruba_cx_8360-32y4caruba_cx_8360-48xt4caruba_cx_8360-24xf2caruba_cx_8320-48paruba_cx_8325-48y8caruba_cx_6405Aruba CX 10000 Switch Series, Aruba CX 9300 Switch Series, Aruba CX 8400 Switch Series, Aruba CX 8360 Switch Series, Aruba CX 8325 Switch Series, Aruba CX 8320 Switch Series, Aruba CX 6400 Switch Series, Aruba CX 6300 Switch Series, Aruba CX 6200F Switch Series
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0861
Matching Score-4
Assigner-ONEKEY GmbH
ShareView Details
Matching Score-4
Assigner-ONEKEY GmbH
CVSS Score-7.2||HIGH
EPSS-1.50% / 80.34%
||
7 Day CHG~0.00%
Published-16 Feb, 2023 | 08:58
Updated-18 Mar, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection in NetModule NSRW

NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.

Action-Not Available
Vendor-netmoduleNetModule
Product-nb1810nb2800nb3800nb1601ng800nb800nb1800netmodule_router_softwarenb3701nb2810NSRW
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-25955
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.22%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 19:05
Updated-27 Jan, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-solutions_enabler_virtual_appliancepowermax_eemunisphere_for_powermax_virtual_applianceVirtual Appliance (vApp) Managerunisphere_for_powermax_virtual_appliancesolutions_enabler_virtual_applianceunisphere_for_powermax
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-26294
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.20% / 41.88%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 21:54
Updated-27 Mar, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-26296
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.28% / 51.29%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 21:57
Updated-27 Mar, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25946
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.22%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 19:00
Updated-25 Mar, 2025 | 14:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-solutions_enabler_virtual_appliancepowermax_eemunisphere_for_powermax_virtual_applianceVirtual Appliance (vApp) Managervirtual_appliance_manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0640
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.91% / 74.91%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 08:14
Updated-26 Mar, 2025 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TRENDnet TEW-652BRP Web Interface ping.ccp command injection

A vulnerability was found in TRENDnet TEW-652BRP 3.04b01. It has been classified as critical. Affected is an unknown function of the file ping.ccp of the component Web Interface. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220020.

Action-Not Available
Vendor-TRENDnet, Inc.
Product-tew-652brp_firmwaretew-652brpTEW-652BRP
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-26295
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.28% / 51.29%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 21:56
Updated-27 Mar, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-28130
Matching Score-4
Assigner-Check Point Software Ltd.
ShareView Details
Matching Score-4
Assigner-Check Point Software Ltd.
CVSS Score-7.2||HIGH
EPSS-3.39% / 86.90%
||
7 Day CHG~0.00%
Published-26 Jul, 2023 | 10:57
Updated-13 Feb, 2025 | 16:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Local user may lead to privilege escalation using Gaia Portal hostnames page.

Action-Not Available
Vendor-n/aCheck Point Software Technologies Ltd.
Product-gaia_portalQuantum Appliances, Quantum Security Gatewaysgaia_portal
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1162
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-35.80% / 96.95%
||
7 Day CHG~0.00%
Published-03 Mar, 2023 | 06:49
Updated-02 Aug, 2024 | 05:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
DrayTek Vigor 2960 Web Management Interface mainfunction.cgi command injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is an unknown function of the file mainfunction.cgi of the component Web Management Interface. The manipulation of the argument password leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-222258 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-DrayTek Corp.
Product-vigor_2960vigor_2960_firmwareVigor 2960
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0638
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.22% / 44.56%
||
7 Day CHG+0.01%
Published-02 Feb, 2023 | 08:05
Updated-02 Aug, 2024 | 05:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TRENDnet TEW-811DRU Web Interface command injection

A vulnerability has been found in TRENDnet TEW-811DRU 1.0.10.0 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-220018 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-TRENDnet, Inc.
Product-tew-811dru_firmwaretew-811druTEW-811DRU
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-26298
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.20% / 41.88%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 22:04
Updated-27 Mar, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0636
Matching Score-4
Assigner-Asea Brown Boveri Ltd. (ABB)
ShareView Details
Matching Score-4
Assigner-Asea Brown Boveri Ltd. (ABB)
CVSS Score-7.2||HIGH
EPSS-0.12% / 32.22%
||
7 Day CHG~0.00%
Published-05 Jun, 2023 | 03:45
Updated-08 Jan, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Remote Code Execution via Command Injection

Improper Input Validation vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Command Injection.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.0; NEXUS Series: from 3.0;0 before 3.07.0; MATRIX Series: from 3.0;0 before 3.07.1.

Action-Not Available
Vendor-ABB
Product-nexus-264-amatrix-11_firmwarematrix-264_firmwarematrix-232nexus-2128-g_firmwarenexus-264nexus-2128-aaspect-ent-96nexus-2128-gnexus-264_firmwarenexus-2128_firmwarenexus-2128-fnexus-264-a_firmwarenexus-2128-a_firmwarematrix-216matrix-296_firmwarematrix-216_firmwareaspect-ent-256nexus-3-264_firmwareaspect-ent-256_firmwareaspect-ent-12matrix-11nexus-264-faspect-ent-2_firmwarenexus-264-g_firmwarenexus-264-f_firmwarenexus-2128nexus-3-2128_firmwarenexus-3-2128matrix-232_firmwarenexus-264-gaspect-ent-12_firmwarematrix-296aspect-ent-2nexus-2128-f_firmwarenexus-3-264aspect-ent-96_firmwarematrix-264MATRIX SeriesNEXUS SeriesASPECT®-Enterprise
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25611
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.13% / 33.10%
||
7 Day CHG~0.00%
Published-05 Mar, 2024 | 20:16
Updated-01 Aug, 2024 | 23:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Authenticated command injection vulnerabilities exist in the ArubaOS command line interface. Successful exploitation of these vulnerabilities result in the ability to execute arbitrary commands as a privileged user on the underlying operating system.

Action-Not Available
Vendor-Aruba NetworksHewlett Packard Enterprise (HPE)
Product-ArubaOS Wi-Fi Controllers and Campus/Remote Access Pointsarubaossd-wan
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25613
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.13% / 33.10%
||
7 Day CHG~0.00%
Published-05 Mar, 2024 | 20:17
Updated-01 Aug, 2024 | 23:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Authenticated command injection vulnerabilities exist in the ArubaOS command line interface. Successful exploitation of these vulnerabilities result in the ability to execute arbitrary commands as a privileged user on the underlying operating system.

Action-Not Available
Vendor-Aruba NetworksHewlett Packard Enterprise (HPE)
Product-ArubaOS Wi-Fi Controllers and Campus/Remote Access Pointsarubaossd-wan
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25612
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.13% / 33.10%
||
7 Day CHG~0.00%
Published-05 Mar, 2024 | 20:16
Updated-01 Aug, 2024 | 23:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Authenticated command injection vulnerabilities exist in the ArubaOS command line interface. Successful exploitation of these vulnerabilities result in the ability to execute arbitrary commands as a privileged user on the underlying operating system.

Action-Not Available
Vendor-Aruba NetworksHewlett Packard Enterprise (HPE)
Product-ArubaOS Wi-Fi Controllers and Campus/Remote Access Pointsarubaossd-wan
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-4934
Matching Score-4
Assigner-Sophos Limited
ShareView Details
Matching Score-4
Assigner-Sophos Limited
CVSS Score-7.2||HIGH
EPSS-0.13% / 33.64%
||
7 Day CHG~0.00%
Published-04 Apr, 2023 | 00:00
Updated-11 Feb, 2025 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A post-auth command injection vulnerability in the exception wizard of Sophos Web Appliance older than version 4.3.10.4 allows administrators to execute arbitrary code.

Action-Not Available
Vendor-Sophos Ltd.
Product-web_applianceSophos Web Appliance
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-21880
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-8.6||HIGH
EPSS-2.49% / 84.71%
||
7 Day CHG~0.00%
Published-10 Aug, 2024 | 17:44
Updated-11 Mar, 2025 | 13:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
URL parameter manipulations allows an authenticated attacker to execute arbitrary OS commands in Enphase IQ Gateway version 4.x <= 7.x

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability via the url parameter of an authenticated enpoint in Enphase IQ Gateway (formerly known as Enphase) allows OS Command Injection.This issue affects Envoy: 4.x <= 7.x

Action-Not Available
Vendor-enphaseEnphaseenphase
Product-iq_gatewayiq_gateway_firmwareEnvoyenvoy
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38518
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.14% / 77.57%
||
7 Day CHG~0.00%
Published-11 Aug, 2021 | 00:02
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax200_firmwarerbs850rax80rax200rbs850_firmwarerax75_firmwarerax75rbr850rax80_firmwarerbk852_firmwarerbk852rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6335
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.20% / 42.26%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 11:00
Updated-18 Jul, 2025 | 12:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
DedeCMS Template dedetag.class.php command injection

A vulnerability was found in DedeCMS up to 5.7.2 and classified as critical. This issue affects some unknown processing of the file /include/dedetag.class.php of the component Template Handler. The manipulation of the argument notes leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-n/aDedeCMS
Product-dedecmsDedeCMS
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-21322
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-7.2||HIGH
EPSS-0.50% / 64.92%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 17:00
Updated-03 May, 2025 | 00:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Microsoft Defender for IoT Remote Code Execution Vulnerability

Microsoft Defender for IoT Remote Code Execution Vulnerability

Action-Not Available
Vendor-Microsoft Corporation
Product-defender_for_iotMicrosoft Defender for IoT
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-55283
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.1||CRITICAL
EPSS-0.06% / 18.61%
||
7 Day CHG+0.02%
Published-18 Aug, 2025 | 16:46
Updated-21 Aug, 2025 | 21:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
aiven-db-migrate allows Privilege Escalation through use of psql during migration

aiven-db-migrate is an Aiven database migration tool. Prior to 1.0.7, there is a privilege escalation vulnerability that allows elevation to superuser inside PostgreSQL databases during a migration from an untrusted source server. The vulnerability stems from psql executing commands embedded in a dump from the source server. This vulnerability is fixed in 1.0.7.

Action-Not Available
Vendor-Aiven
Product-aiven-db-migrateaiven-db-migrate
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11652
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.39% / 58.94%
||
7 Day CHG+0.05%
Published-25 Nov, 2024 | 03:00
Updated-12 Feb, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT sn_https command injection

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /admin/sn_package/sn_https. The manipulation of the argument https_enable leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengeniustech
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTenh1350ext_firmwareens500-ac_firmwareens620ext_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-20365
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.30% / 52.45%
||
7 Day CHG~0.00%
Published-02 Oct, 2024 | 16:52
Updated-08 Oct, 2024 | 14:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Integrated Management Controller Redfish Command Injection Vulnerability

A vulnerability in the Redfish API of Cisco UCS B-Series, Cisco UCS Managed C-Series, and Cisco UCS X-Series Servers could allow an authenticated, remote attacker with administrative privileges to perform command injection attacks on an affected system and elevate privileges to root. This vulnerability is due to insufficient input validation. An attacker with administrative privileges could exploit this vulnerability by sending crafted commands through the Redfish API on an affected device. A successful exploit could allow the attacker to elevate privileges to root.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-unified_computing_systemCisco Unified Computing System (Managed)unified_computing_system_manager_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-37106
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-7.2||HIGH
EPSS-0.48% / 64.07%
||
7 Day CHG~0.00%
Published-28 Sep, 2021 | 14:02
Updated-04 Aug, 2024 | 01:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability in CMA service module of FusionCompute 6.3.0, 6.3.1, 6.5.0 and 8.0.0 when processing the default certificate file. The software constructs part of a command using external special input from users, but the software does not sufficiently validate the user input. Successful exploit could allow the attacker to inject certain commands to the system.

Action-Not Available
Vendor-n/aHuawei Technologies Co., Ltd.
Product-fusioncomputeFusionCompute
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-20287
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 23.94%
||
7 Day CHG~0.00%
Published-17 Jan, 2024 | 16:58
Updated-02 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based management interface of the Cisco WAP371 Wireless-AC/N Dual Radio Access Point (AP) with Single Point Setup could allow an authenticated, remote attacker to perform command injection attacks against an affected device. This vulnerability is due to improper validation of user-supplied input. An attacker could exploit this vulnerability by sending crafted HTTP requests to the web-based management interface of an affected system. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the device. To exploit this vulnerability, the attacker must have valid administrative credentials for the device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-wap371_firmwarewap371Cisco Business Wireless Access Point Software
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-37721
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-3.55% / 87.23%
||
7 Day CHG~0.00%
Published-07 Sep, 2021 | 12:35
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.4, 8.6.0.9, 8.5.0.13, 8.3.0.16, 6.5.4.20, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaossd-wanscalance_w1750d_firmwarescalance_w1750dAruba SD-WAN Software and Gateways; Aruba Operating System Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-37717
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-3.55% / 87.23%
||
7 Day CHG~0.00%
Published-07 Sep, 2021 | 12:05
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.6; Prior to 8.7.1.4, 8.6.0.7, 8.5.0.12, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaossd-wanscalance_w1750d_firmwarescalance_w1750dAruba SD-WAN Software and Gateways; Aruba Operating System Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-1356
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.13% / 33.10%
||
7 Day CHG~0.00%
Published-05 Mar, 2024 | 20:14
Updated-01 Aug, 2024 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Authenticated command injection vulnerabilities exist in the ArubaOS command line interface. Successful exploitation of these vulnerabilities result in the ability to execute arbitrary commands as a privileged user on the underlying operating system.

Action-Not Available
Vendor-Aruba NetworksHewlett Packard Enterprise (HPE)
Product-ArubaOS Wi-Fi Controllers and Campus/Remote Access Pointsarubaossd-wan
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-37724
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-2.07% / 83.19%
||
7 Day CHG~0.00%
Published-07 Sep, 2021 | 12:34
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba Operating System Software version(s): Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.16. Aruba has released patches for ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwarescalance_w1750dAruba Operating System Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-13062
Matching Score-4
Assigner-ASUSTeK Computer Incorporation
ShareView Details
Matching Score-4
Assigner-ASUSTeK Computer Incorporation
CVSS Score-7.2||HIGH
EPSS-0.17% / 38.80%
||
7 Day CHG~0.00%
Published-02 Jan, 2025 | 09:09
Updated-06 Jan, 2025 | 20:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unintended entry point vulnerability has been identified in certain router models, which may allow for arbitrary command execution. Refer to the ' 01/02/2025 ASUS Router AiCloud vulnerability' section on the ASUS Security Advisory for more information.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)
Product-Router
CWE ID-CWE-912
Hidden Functionality
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-12912
Matching Score-4
Assigner-ASUSTeK Computer Incorporation
ShareView Details
Matching Score-4
Assigner-ASUSTeK Computer Incorporation
CVSS Score-7.2||HIGH
EPSS-0.25% / 47.99%
||
7 Day CHG~0.00%
Published-02 Jan, 2025 | 09:05
Updated-06 Jan, 2025 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper input insertion vulnerability in AiCloud on certain router models may lead to arbitrary command execution. Refer to the '01/02/2025 ASUS Router AiCloud vulnerability' section on the ASUS Security Advisory for more information.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)
Product-Router
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2024-11659
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.44%
||
7 Day CHG+0.19%
Published-25 Nov, 2024 | 06:31
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_iperf command injection

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118 and classified as critical. Affected by this issue is some unknown functionality of the file /admin/network/diag_iperf. The manipulation of the argument iperf leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11656
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.44%
||
7 Day CHG+0.19%
Published-25 Nov, 2024 | 05:00
Updated-12 Feb, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_ping6 command injection

A vulnerability, which was classified as critical, has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This issue affects some unknown processing of the file /admin/network/diag_ping6. The manipulation of the argument diag_ping6 leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • Next
Details not found