Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-39571

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-09 Jul, 2024 | 12:05
Updated At-01 May, 2025 | 03:55
Rejected At-
Credits

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:09 Jul, 2024 | 12:05
Updated At:01 May, 2025 | 03:55
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.

Affected Products
Vendor
Siemens AGSiemens
Product
SINEMA Remote Connect Server
Default Status
unknown
Versions
Affected
  • From 0 before V3.2 HF1 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-928781.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-928781.html
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Vendor
Siemens AGsiemens
Product
sinema_remote_connect_server
CPEs
  • cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • From 0 before 3.2_hf1 (custom)
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-928781.html
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-928781.html
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:09 Jul, 2024 | 12:15
Updated At:06 Sep, 2024 | 21:20

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading SNMP configurations. This could allow an attacker with the right to modify the SNMP configuration to execute arbitrary code with root privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>sinema_remote_connect_server>>Versions before 3.2(exclusive)
cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinema_remote_connect_server>>3.2
cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:-:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE-77Secondaryproductcert@siemens.com
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-77
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-928781.htmlproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-928781.html
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

525Records found

CVE-2022-45094
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.4||HIGH
EPSS-0.71% / 71.33%
||
7 Day CHG~0.00%
Published-10 Jan, 2023 | 11:39
Updated-09 Apr, 2025 | 14:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.

Action-Not Available
Vendor-Siemens AG
Product-sinec_insSINEC INS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-32262
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-2.15% / 83.55%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-21 Apr, 2025 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39570
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-1.92% / 82.60%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-01 May, 2025 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-4845
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.79%
||
7 Day CHG~0.00%
Published-26 Jun, 2018 | 18:00
Updated-16 Sep, 2024 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-rapidlab_1200_firmwarerapidpoint_500_firmwarerapidpoint_500rapidpoint_400_firmwarerapidlab_1200rapidpoint_400RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systems
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-37173
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.55% / 80.67%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The command line interface of affected devices insufficiently restrict file read and write operations for low privileged users. This could allow an authenticated remote attacker to escalate privileges and gain root access to the device.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareRUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-33729
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.32% / 79.06%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-40735
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.94%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected devices are vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-40738
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.76%
||
7 Day CHG+0.01%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26572).

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-40737
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.76%
||
7 Day CHG+0.01%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26571).

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-31888
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.72% / 81.63%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwareapogee_modular_equiment_controller_firmwaredesigo_pxc12-e.dapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaretalon_tc_modular_firmwaretalon_tc_modulardesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-udesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DAPOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Desigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-170
Improper Null Termination
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-32847
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32848
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32856
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32850
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32860
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32824
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32846
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32851
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32833
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32837
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32826
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32852
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32832
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32859
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32838
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32828
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32854
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32823
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32822
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'DeleteProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32865
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32849
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32867
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32862
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32825
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32841
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32831
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32864
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32871
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32872
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:39
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32834
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32843
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32827
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ActivateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32863
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32853
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32839
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32861
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32830
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32836
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32842
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32868
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.77%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 10
  • 11
  • Next
Details not found