A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda A15 15.13.07.13. The impacted element is the function UploadCfg of the file /cgi-bin/UploadCfg. The manipulation of the argument File leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security parameter at /goform/WifiBasicSet.
A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing a manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
A vulnerability was identified in Tenda O3 1.0.0.10(2478). Affected by this vulnerability is the function SetValue/GetValue of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey1 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey3 parameter at /goform/WifiBasicSet.
A security flaw has been discovered in Tenda O3 1.0.0.10(2478). Affected by this issue is the function SetValue/GetValue of the file /goform/setDmzInfo. The manipulation of the argument dmzIP results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.
A security vulnerability has been detected in Tenda CH22 up to 1.0.0.1. This issue affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP Request Handler. The manipulation of the argument mit_ssid_index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
A vulnerability has been found in Tenda W12 3.0.0.6(3948). The affected element is the function wifiMacFilterSet of the file /goform/modules of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
A vulnerability has been found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.20. Affected is the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument sysTimePolicy leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapsk_crypto2_4g results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.