Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.
Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.
Tenda G3 Router firmware v15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the usbPartitionName parameter in the formSetUSBPartitionUmount function.
Tenda AC15V1.0 V15.03.20_multi has a command injection vulnerability via the deviceName parameter.
A stack overflow vulnerability in Tenda AC23 with firmware version US_AC23V1.0re_V16.03.07.45_cn_TDC01 allows attackers to run arbitrary commands via schedStartTime parameter.
A vulnerability was found in Tenda CX12L 16.03.53.12. Affected by this vulnerability is the function fromP2pListFilter of the file /goform/P2pListFilter. Performing a manipulation of the argument page results in stack-based buffer overflow. The attack must originate from the local network. The exploit has been made public and could be used.
Tenda W9 v1.0.0.7(4456) was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root.
Tenda G3 v15.01.0.5(2848_755)_EN was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root
A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function.
Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo.
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function.
Tenda W30E v2.0 V16.01.0.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function setIptvInfo.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the serverName parameter in the function form_fast_setting_internet_set.
AX3000 Dual-Band Gigabit Wi-Fi 6 Router AX9 V22.03.01.46 and AX3000 Dual-Band Gigabit Wi-Fi 6 Router AX12 V1.0 V22.03.01.46 were discovered to contain an authenticated remote command execution (RCE) vulnerability via the macFilterType parameter at /goform/setMacFilterCfg.
A vulnerability was found in Tenda CH22 1.0.0.1. This vulnerability affects the function fromSetIpBind of the file /goform/SetIpBind. The manipulation of the argument page results in buffer overflow. The attack must originate from the local network. The exploit has been made public and could be used.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formSetIptv.
Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function.
Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.
Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function.
Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the page parameter of the fromDhcpListClient function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the schedEndTime parameter from setSchedWifi function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the page parameter of the fromAddressNat function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the entrys parameter from fromAddressNat function.
Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`.
Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the mitInterface parameter of the fromAddressNat function.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.
A vulnerability was determined in Tenda CX12L 16.03.53.12. Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack requires access to the local network. The exploit has been publicly disclosed and may be utilized.
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function.
Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function.
Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request.
Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formSetDiagnoseInfo .
A vulnerability was found in Tenda W6-S 1.0.0.4(510). This affects the function TendaAte of the file /goform/ate of the component ATE Service. Performing a manipulation results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used.
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
Command injection vulnerability found in Tenda G103 v.1.0.0.5 allows attacker to execute arbitrary code via a the language parameter.
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
A security flaw has been discovered in Tenda HG3 2.0 300003070. This vulnerability affects the function formgponConf of the file /boaform/admin/formgponConf. The manipulation of the argument fmgpon_loid results in os command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.
A vulnerability was detected in Tenda HG3 2.0. The impacted element is an unknown function of the file /boaform/formCountrystr. The manipulation of the argument countrystr results in os command injection. The attack may be performed from remote. The exploit is now public and may be used.
A vulnerability has been found in Tenda AC6 2.0/15.03.06.23. The affected element is an unknown function of the file /goform/telnet of the component httpd. The manipulation of the argument lan.ip leads to os command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.
Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.