Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
A vulnerability was determined in Tenda i12 1.0.0.11(3862). The impacted element is an unknown function of the component HTTP Handler. Executing a manipulation can lead to path traversal. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Tenda WH450 v1.0.0.18 was discovered to contain a buffer overflow via the function fgets.
Tenda AC6 _US_AC6V1.0BR_V15.03.05.16 was discovered to contain a buffer overflow via the function fgets.
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode.
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg.
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB.
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting.
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
A vulnerability has been found in Tenda A15 15.13.07.13. The impacted element is the function UploadCfg of the file /cgi-bin/UploadCfg. The manipulation of the argument File leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
Tenda AX9 V22.03.01.46 has been discovered to contain a command injection vulnerability in the 'mac' parameter at /goform/SetOnlineDevName.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
A vulnerability was identified in Tenda AC8 16.03.50.11. Affected by this issue is the function check_is_ipv6 of the component IPv6 Handler. The manipulation leads to reliance on ip address for authentication. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.
Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey4 parameter at /goform/WifiBasicSet.
Tenda W30E V2.0 V16.01.0.21 was found to contain a command injection vulnerability in the formSetUSBPartitionUmount function via the usbPartitionName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd_5g parameter at /goform/WifiBasicSet.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapsk_crypto2_4g results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteFacMac.
There is an unauthorized buffer overflow vulnerability in Tenda AX12 v22.03.01.21 _ cn. This vulnerability can cause the web service not to restart or even execute arbitrary code. It is a different vulnerability from CVE-2022-2414.
A vulnerability was found in Tenda F453 1.0.0.3. This impacts the function fromP2pListFilter of the file /goform/P2pListFilterof of the component httpd. The manipulation of the argument page results in buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.