Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-57704

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-16 Jan, 2025 | 00:00
Updated At-03 Feb, 2025 | 20:34
Rejected At-
Credits

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:16 Jan, 2025 | 00:00
Updated At:03 Feb, 2025 | 20:34
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md
N/A
Hyperlink: https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-787CWE-787 Out-of-bounds Write
Type: CWE
CWE ID: CWE-787
Description: CWE-787 Out-of-bounds Write
Metrics
VersionBase scoreBase severityVector
3.14.6MEDIUM
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Version: 3.1
Base score: 4.6
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:16 Jan, 2025 | 23:15
Updated At:17 Mar, 2025 | 15:04

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.14.6MEDIUM
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 4.6
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ac8_firmware>>16.03.34.06
cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ac8>>4.0
cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE-787Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-787
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.mdcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

1097Records found

CVE-2025-3328
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 39.03%
||
7 Day CHG~0.00%
Published-07 Apr, 2025 | 00:31
Updated-07 Apr, 2025 | 18:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 fast_setting_wifi_set form_fast_setting_wifi_set buffer overflow

A vulnerability was found in Tenda AC1206 15.03.06.23. It has been classified as critical. Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid/timeZone leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206ac1206_firmwareAC1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-3259
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.20% / 41.85%
||
7 Day CHG~0.00%
Published-04 Apr, 2025 | 17:31
Updated-07 Apr, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3rx3_firmwareRX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-0566
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.45% / 62.68%
||
7 Day CHG+0.05%
Published-19 Jan, 2025 | 06:31
Updated-01 Jul, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDevNetName formSetDevNetName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.13.07.13. This affects the function formSetDevNetName of the file /goform/SetDevNetName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-0349
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.48% / 64.20%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 10:31
Updated-22 Mar, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8229
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 36.60%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:31
Updated-29 Aug, 2024 | 00:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O6 operateMacFilter frommacFilterModify stack-based overflow

A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o6_firmwareo6O6o6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8227
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.49% / 64.55%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:00
Updated-29 Aug, 2024 | 00:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O1 DhcpSetSer fromDhcpSetSer stack-based overflow

A vulnerability was found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o1o1_firmwareO1o1_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8228
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 35.11%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:00
Updated-29 Aug, 2024 | 00:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O5 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O5 1.0.0.8(5017). It has been classified as critical. This affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o5_firmwareo5O5o5_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8224
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.43% / 62.03%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 23:00
Updated-13 Dec, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G3 setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g3g3_firmwareG3g3_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8230
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 36.60%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 01:00
Updated-29 Aug, 2024 | 00:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O6 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o6_firmwareo6O6o6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8225
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.46% / 63.05%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 23:00
Updated-29 Aug, 2024 | 00:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G3 SetSysTimeCfg formSetSysTime stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.20. Affected is the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument sysTimePolicy leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g3g3_firmwareG3g3_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7151
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.41% / 60.68%
||
7 Day CHG~0.00%
Published-27 Jul, 2024 | 20:00
Updated-01 Oct, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setMacFilter fromMacFilterSet stack-based overflow

A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7581
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.04% / 76.58%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 15:00
Updated-07 Aug, 2024 | 19:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow

A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7583
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.81% / 73.27%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 16:00
Updated-08 Aug, 2024 | 20:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow

A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6965
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.43% / 61.62%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 01:31
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 fromVirtualSet stack-based overflow

A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O3o3v2o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6962
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.46% / 63.07%
||
7 Day CHG~0.00%
Published-21 Jul, 2024 | 23:31
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 formQosSet stack-based overflow

A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O3o3v2
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6964
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.16% / 77.73%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 01:00
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 fromDhcpSetSer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda O3 1.0.0.10. Affected is the function fromDhcpSetSer. The manipulation of the argument dhcpEn/startIP/endIP/preDNS/altDNS/mask/gateway leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272118 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O303v2.0_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7582
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.81% / 73.27%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 15:31
Updated-08 Aug, 2024 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow

A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6963
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-2.44% / 84.56%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 00:00
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 formexeCommand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O3o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7707
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.95% / 75.47%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-22 Aug, 2024 | 13:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow

A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7613
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.62%
||
7 Day CHG~0.00%
Published-08 Aug, 2024 | 22:00
Updated-21 Aug, 2024 | 18:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 GstDhcpSetSer fromGstDhcpSetSer buffer overflow

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7615
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.85%
||
7 Day CHG~0.00%
Published-08 Aug, 2024 | 22:31
Updated-21 Aug, 2024 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 fromSafeUrlFilter stack-based overflow

A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7152
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.07% / 76.79%
||
7 Day CHG~0.00%
Published-27 Jul, 2024 | 21:00
Updated-01 Nov, 2024 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7614
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.85%
||
7 Day CHG~0.00%
Published-08 Aug, 2024 | 22:31
Updated-21 Aug, 2024 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 qossetting fromqossetting stack-based overflow

A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6189
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.47% / 63.77%
||
7 Day CHG~0.00%
Published-20 Jun, 2024 | 14:00
Updated-01 Nov, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4495
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.73%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:31
Updated-27 Jan, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4494
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.88%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:00
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4245
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.23%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 07:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManageDouble_user stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27042
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.76%
||
7 Day CHG~0.00%
Published-24 Mar, 2023 | 00:00
Updated-20 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX3 V16.03.12.11 is vulnerable to Buffer Overflow via /goform/SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax3ax3_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4066
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.64% / 69.69%
||
7 Day CHG~0.00%
Published-23 Apr, 2024 | 21:00
Updated-21 Jan, 2025 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4112
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.12%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4115
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.78%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 15:31
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E AddDnsForward formAddDnsForward stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8231
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 38.34%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 01:00
Updated-16 Oct, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O6 setPortForward fromVirtualSet stack-based overflow

A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o6_firmwareo6O6o6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8226
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.46% / 63.05%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 23:31
Updated-29 Aug, 2024 | 00:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O1 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o1o1_firmwareO1o1_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4252
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.18%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 13:31
Updated-27 Jan, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 formSetUrlFilterRule stack-based overflow

A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-36568
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.17% / 38.81%
||
7 Day CHG~0.00%
Published-31 Aug, 2022 | 19:03
Updated-03 Aug, 2024 | 10:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2984
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.71%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-14 Jan, 2025 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4168
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.62% / 69.21%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4260F0 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4242
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.94%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:00
Updated-27 Jan, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4243
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.94%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4170
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.90%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 13:00
Updated-21 Jan, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_429A30 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4121
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E formQOSRuleDel stack-based overflow

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4111
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.12%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:00
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4118
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.34%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:31
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3909
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.36%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:31
Updated-07 Feb, 2025 | 01:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 execCommand formexeCommand stack-based overflow

A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3906
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.50% / 64.94%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 10:31
Updated-21 Jan, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3910
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.07%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3876
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.03%
||
7 Day CHG-0.21%
Published-16 Apr, 2024 | 18:00
Updated-21 Jan, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3882
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.55%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E fromRouteStatic stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2988
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.36%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:31
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2989
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.96%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 21
  • 22
  • Next
Details not found