A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
An information disclosure vulnerability exists in the web interface /cgi-bin/download_config.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.
netentsec NS-ASG 6.3 is vulnerable to Incorrect Access Control. There is a file leak in the website source code of the application security gateway.
Loftware Spectrum through 4.6 has unprotected JMX Registry.
Incorrect Access Control in ITB-GmbH TradePro v9.5, allows remote attackers to receive all orders from the online shop via oordershow component in customer function.
VISAM VBASE version 11.6.0.6 is vulnerable to improper access control via the web-remote endpoint, which may allow an unauthenticated user viewing access to folders and files in the directory listing.
GLPI is a free asset and IT management software package. Starting in version 9.5.0 and prior to version 10.0.8, an incorrect rights check on a file allows an unauthenticated user to be able to access dashboards data. Version 10.0.8 contains a patch for this issue.
An incorrect access control vulnerability in powerjob 4.3.2 and earlier allows remote attackers to obtain sensitive information via the interface for querying via appId parameter to /container/list.
Improper access control in user mode driver for some Intel(R) Connectivity Performance Suite before version 2.1123.214.2 may allow unauthenticated user to potentially enable information disclosure via network access.
In zulip before 1.3.12, deactivated users could access messages if SSO was enabled.
fs.openAsBlob() can bypass the experimental permission model when using the file system read restriction with the `--allow-fs-read` flag in Node.js 20. This flaw arises from a missing check in the `fs.openAsBlob()` API. Please note that at the time this CVE was issued, the permission model is an experimental feature of Node.js.
Adobe ColdFusion versions 2018u16 (and earlier), 2021u6 (and earlier) and 2023.0.0.330468 (and earlier) are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. An attacker could leverage this vulnerability to access the administration CFM and CFC endpoints. Exploitation of this issue does not require user interaction.
Cloud Foundry UAA, versions prior to v73.4.0, does not set an X-FRAME-OPTIONS header on various endpoints. A remote user can perform clickjacking attacks on UAA's frontend sites.
Advantech WebAccess 8.3.4 does not properly restrict an RPC call that allows unauthenticated, remote users to read files. An attacker can use this vulnerability to recover the administrator password.
An issue was discovered on TK-Star Q90 Junior GPS horloge 3.1042.9.8656 devices. It performs actions based on certain SMS commands. This can be used to set up a voice communication channel from the watch to any telephone number, initiated by sending a specific SMS and using the default password, e.g., pw,<password>,call,<mobile_number> triggers an outbound call from the watch. The password is sometimes available because of CVE-2019-20471.
A vulnerability in open build service allows remote attackers to gain access to source files even though source access is disabled. Affected releases are SUSE open build service up to and including version 2.1.15 (for 2.1) and before version 2.3.
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
An access control issue exists in < 12.3.5, < 12.2.8, and < 12.1.14 for GitLab Community Edition (CE) and Enterprise Edition (EE) where private merge requests and issues would be disclosed with the Group Search feature provided by Elasticsearch integration
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
eLabFTW is an open source electronic lab notebook for research labs. An incorrect permission check has been found that could allow an authenticated user to access several kinds of otherwise restricted information. If anonymous access is allowed (something disabled by default), this extends to anyone. Users are advised to upgrade to at least version 5.1.0. System administrators can disable anonymous access in the System configuration panel.
Improper access control in Imagine Cup allows an authorized attacker to elevate privileges over a network.
An issue in Shenzhen Weitillage Industrial Co., Ltd the access management specialist V6.62.51215 allows a remote attacker to obtain sensitive information.
Incorrect access control in the preHandle function of my-site v1.0.2 allows attackers to access sensitive components without authentication via the cn.luischen.interceptor.BaseInterceptor class
An improper access control vulnerability exists in the gaizhenbiao/chuanhuchatgpt application, specifically in version 20240410. This vulnerability allows any user on the server to access the chat history of any other user without requiring any form of interaction between the users. Exploitation of this vulnerability could lead to data breaches, including the exposure of sensitive personal details, financial data, or confidential conversations. Additionally, it could facilitate identity theft and manipulation or fraud through the unauthorized access to users' chat histories. This issue is due to insufficient access control mechanisms in the application's handling of chat history data.