Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-8228

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-28 Aug, 2024 | 00:00
Updated At-28 Aug, 2024 | 15:56
Rejected At-
Credits

Tenda O5 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O5 1.0.0.8(5017). It has been classified as critical. This affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:28 Aug, 2024 | 00:00
Updated At:28 Aug, 2024 | 15:56
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda O5 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O5 1.0.0.8(5017). It has been classified as critical. This affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
O5
Versions
Affected
  • 1.0.0.8(5017)
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
yhryhryhr_miemie (VulDB User)
Timeline
EventDate
Advisory disclosed2024-08-27 00:00:00
VulDB entry created2024-08-27 02:00:00
VulDB entry last update2024-08-27 15:17:34
Event: Advisory disclosed
Date: 2024-08-27 00:00:00
Event: VulDB entry created
Date: 2024-08-27 02:00:00
Event: VulDB entry last update
Date: 2024-08-27 15:17:34
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.275937
vdb-entry
technical-description
https://vuldb.com/?ctiid.275937
signature
permissions-required
https://vuldb.com/?submit.394029
third-party-advisory
https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O5V1.0/fromSafeSetMacFilter.md
exploit
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.275937
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.275937
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.394029
Resource:
third-party-advisory
Hyperlink: https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O5V1.0/fromSafeSetMacFilter.md
Resource:
exploit
Hyperlink: https://www.tenda.com.cn/
Resource:
product
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Vendor
Tenda Technology Co., Ltd.tenda
Product
o5_firmware
CPEs
  • cpe:2.3:o:tenda:o5_firmware:*:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 1.0.0.8\(5017\)
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:28 Aug, 2024 | 00:15
Updated At:29 Aug, 2024 | 00:11

A vulnerability was found in Tenda O5 1.0.0.8(5017). It has been classified as critical. This affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>o5_firmware>>1.0.0.8\(5017\)
cpe:2.3:o:tenda:o5_firmware:1.0.0.8\(5017\):*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>o5>>-
cpe:2.3:h:tenda:o5:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE-121Secondarycna@vuldb.com
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-121
Type: Secondary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O5V1.0/fromSafeSetMacFilter.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.275937cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.275937cna@vuldb.com
VDB Entry
https://vuldb.com/?submit.394029cna@vuldb.com
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
Hyperlink: https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/web-bridge/O5V1.0/fromSafeSetMacFilter.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.275937
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.275937
Source: cna@vuldb.com
Resource:
VDB Entry
Hyperlink: https://vuldb.com/?submit.394029
Source: cna@vuldb.com
Resource:
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

3451Records found

CVE-2024-2993
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.84%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2978
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-10 Apr, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 setcfm formSetCfm stack-based overflow

A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2902
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.72%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2987
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 71.63%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47126
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 32.76%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2980
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.93%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:31
Updated-14 Jan, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47128
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 32.76%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey2 parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2988
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.38%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:31
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.13%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:00
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2979
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2981
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.93%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 15:00
Updated-14 Jan, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2899
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:00
Updated-10 Apr, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2977
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.93%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25450
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.39% / 84.41%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 20:53
Updated-03 Aug, 2024 | 04:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47122
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd_5g parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47123
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey3 parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2976
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.00% / 76.09%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47119
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2983
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.72%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetClientState formSetClientState stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47115
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepauth parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2989
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.97%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2900
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.95% / 75.39%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:31
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 saveParentControlInfo stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47127
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 32.76%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2895
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:31
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47125
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn_5g parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-45781
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.16%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 00:00
Updated-03 Sep, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1803_firmwareax1803n/aax1803_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2894
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:00
Updated-22 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetNetControlList formSetQosBand stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2901
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-44363
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 36.34%
||
7 Day CHG+0.03%
Published-02 Dec, 2022 | 00:00
Updated-24 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setSnmpInfo.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-i21_firmwarei21n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2990
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.97%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-44362
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 36.34%
||
7 Day CHG+0.03%
Published-02 Dec, 2022 | 00:00
Updated-24 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/AddSysLogRule.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-i21_firmwarei21n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2892
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.79%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:00
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2891
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.88% / 74.36%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 14:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 QuickIndex formQuickIndex stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2896
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:00
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-44365
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 36.34%
||
7 Day CHG+0.03%
Published-02 Dec, 2022 | 00:00
Updated-24 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda i21 V1.0.0.14(4656) has a stack overflow vulnerability via /goform/setSysPwd.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-i21_firmwarei21n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2490
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.17%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:31
Updated-14 Jan, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2810
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.38%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-12 Aug, 2024 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-28383
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 52.22%
||
7 Day CHG~0.00%
Published-14 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 v1.0 v22.03.01.16 was discovered to contain a stack overflow via the ssid parameter in the sub_431CF0 function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/aax12_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2850
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.57%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2807
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.97%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-10 Apr, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2809
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.65% / 69.98%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-01 Aug, 2024 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2815
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.38%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2856
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.93%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 06:31
Updated-21 Aug, 2024 | 15:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2763
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.69%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2811
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.84%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:00
Updated-21 Aug, 2024 | 22:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-43024
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.17% / 38.78%
||
7 Day CHG~0.00%
Published-19 Oct, 2022 | 00:00
Updated-09 May, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-tx3tx3_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2813
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.38%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-23 Aug, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2805
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.58%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 03:00
Updated-24 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-28553
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.69%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 00:00
Updated-28 Aug, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwaren/aac18_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-43105
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.09% / 27.20%
||
7 Day CHG~0.00%
Published-03 Nov, 2022 | 00:00
Updated-05 May, 2025 | 13:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23ac23_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 69
  • 70
  • Next
Details not found