Vulnerability Details :

CVE-2025-12232

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Oct, 2025 | 06:22
Updated At-24 Feb, 2026 | 07:08
Rejected At-
Credits

Tenda CH22 SafeClientFilter fromSafeClientFilter buffer overflow

A vulnerability was detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromSafeClientFilter of the file /goform/SafeClientFilter. Performing a manipulation of the argument page results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Oct, 2025 | 06:22
Updated At:24 Feb, 2026 | 07:08
Rejected At:
â–¼CVE Numbering Authority (CNA)
Tenda CH22 SafeClientFilter fromSafeClientFilter buffer overflow

A vulnerability was detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromSafeClientFilter of the file /goform/SafeClientFilter. Performing a manipulation of the argument page results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
CH22
CPEs
  • cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
Versions
Affected
  • 1.0.0.1
Problem Types
TypeCWE IDDescription
CWECWE-120Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-120
Description: Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
LINXI666 (VulDB User)
Timeline
EventDate
Advisory disclosed2025-10-25 00:00:00
VulDB entry created2025-10-25 02:00:00
VulDB entry last update2025-10-28 08:02:49
Event: Advisory disclosed
Date: 2025-10-25 00:00:00
Event: VulDB entry created
Date: 2025-10-25 02:00:00
Event: VulDB entry last update
Date: 2025-10-28 08:02:49
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.329902
vdb-entry
technical-description
https://vuldb.com/?ctiid.329902
signature
permissions-required
https://vuldb.com/?submit.673713
third-party-advisory
https://github.com/QIU-DIE/CVE/issues/13
broken-link
exploit
issue-tracking
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.329902
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.329902
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.673713
Resource:
third-party-advisory
Hyperlink: https://github.com/QIU-DIE/CVE/issues/13
Resource:
broken-link
exploit
issue-tracking
Hyperlink: https://www.tenda.com.cn/
Resource:
product
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/QIU-DIE/CVE/issues/13
exploit
Hyperlink: https://github.com/QIU-DIE/CVE/issues/13
Resource:
exploit
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Oct, 2025 | 07:15
Updated At:24 Feb, 2026 | 08:16

A vulnerability was detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromSafeClientFilter of the file /goform/SafeClientFilter. Performing a manipulation of the argument page results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ch22_firmware>>1.0.0.1
cpe:2.3:o:tenda:ch22_firmware:1.0.0.1:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ch22>>*
cpe:2.3:h:tenda:ch22:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Secondarycna@vuldb.com
CWE-120Secondarycna@vuldb.com
CWE ID: CWE-119
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-120
Type: Secondary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/QIU-DIE/CVE/issues/13cna@vuldb.com
Exploit
Issue Tracking
Third Party Advisory
https://vuldb.com/?ctiid.329902cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.329902cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.673713cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
https://github.com/QIU-DIE/CVE/issues/13134c704f-9b21-4f2e-91b3-4a467353bcc0
Exploit
Issue Tracking
Third Party Advisory
Hyperlink: https://github.com/QIU-DIE/CVE/issues/13
Source: cna@vuldb.com
Resource:
Exploit
Issue Tracking
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.329902
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.329902
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.673713
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product
Hyperlink: https://github.com/QIU-DIE/CVE/issues/13
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Resource:
Exploit
Issue Tracking
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

3076Records found

CVE-2025-10803
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.26% / 49.20%
||
7 Day CHG+0.08%
Published-22 Sep, 2025 | 15:02
Updated-24 Sep, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow

A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-0349
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.45% / 63.49%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 10:31
Updated-22 Mar, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7584
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.15%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 16:31
Updated-11 Sep, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow

A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-14992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.76%
||
7 Day CHG+0.02%
Published-21 Dec, 2025 | 04:02
Updated-24 Feb, 2026 | 05:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 HTTP Request GetParentControlInfo strcpy stack-based overflow

A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14994
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.75%
||
7 Day CHG+0.02%
Published-21 Dec, 2025 | 07:32
Updated-31 Dec, 2025 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow

A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206fh1201_firmwarefh1201fh1206_firmwareFH1201FH1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-13400
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-19 Nov, 2025 | 17:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 WrlExtraGet formWrlExtraGet buffer overflow

A vulnerability was detected in Tenda CH22 1.0.0.1. Affected is the function formWrlExtraGet of the file /goform/WrlExtraGet. Performing a manipulation of the argument chkHz results in buffer overflow. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11324
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.65%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 06:32
Updated-24 Feb, 2026 | 06:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 setNotUpgrade stack-based overflow

A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11418
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.42% / 61.91%
||
7 Day CHG~0.00%
Published-08 Oct, 2025 | 00:02
Updated-24 Feb, 2026 | 06:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 HTTP Request AdvSetWrlsafeset formWrlsafeset stack-based overflow

A security vulnerability has been detected in Tenda CH22 up to 1.0.0.1. This issue affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP Request Handler. The manipulation of the argument mit_ssid_index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11525
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.74%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:32
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetUpnpCfg stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-45483
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.70%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-02 Aug, 2024 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-45480
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.70%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-02 Aug, 2024 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-45484
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.70%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-02 Aug, 2024 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-45479
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.70%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-02 Aug, 2024 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-45481
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 47.41%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-05 Jun, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10_firmwareac10n/aac10
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-24440
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-8.7||HIGH
EPSS-0.05% / 15.45%
||
7 Day CHG+0.01%
Published-26 Jan, 2026 | 17:38
Updated-28 Jan, 2026 | 19:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Allows Password Changes Without Verifying Current Password

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-620
Unverified Password Change
CVE-2023-41560
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41557
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac5ac7ac5_firmwareac7_firmwaren/aac5ac7
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40797
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.54%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 18:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2023-40898
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40800
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.54%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2023-40845
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40798
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.54%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2026-24436
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-9.2||CRITICAL
EPSS-0.04% / 11.98%
||
7 Day CHG~0.00%
Published-26 Jan, 2026 | 17:40
Updated-28 Jan, 2026 | 19:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Lacks Rate Limiting on Authentication

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2023-41554
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41563
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 18:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac5ac5_firmwareac9ac9_firmwaren/aac5ac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40942
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-07 Sep, 2023 | 00:00
Updated-26 Sep, 2024 | 17:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9v3.0br
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41556
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 36.61%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac5ac7ac7_firmwareac5_firmwareac9ac9_firmwaren/aac5ac7ac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40904
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10v4ac10v4_firmwaren/aac10v4_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40893
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40847
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 13:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40837
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.11% / 30.07%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-40901
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 33.11%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10v4ac10v4_firmwaren/aac10
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41559
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 36.61%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac5ac7ac7_firmwareac5_firmwareac9ac9_firmwaren/aac5ac7ac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40897
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40892
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40894
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40843
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 20:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004."

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40848
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858."

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41555
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7ac7_firmwaren/aac7
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40801
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.18%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2023-40842
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler."

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41558
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7ac7_firmwaren/aac7
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40896
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40838
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 36.02%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 20:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-40891
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-24101
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.86%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 19:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, `s1_1` will be passed into sub_B0488, concatenated into `doSystemCmd`. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-24429
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-9.3||CRITICAL
EPSS-0.11% / 30.04%
||
7 Day CHG+0.01%
Published-26 Jan, 2026 | 17:39
Updated-29 Jan, 2026 | 13:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Hardcoded Default Password for Built-in Account

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-1393
Use of Default Password
CVE-2023-40839
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.11% / 30.07%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADF3C' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADF3C" function to execute commands.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/aac6
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-24428
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.66%
||
7 Day CHG+0.01%
Published-26 Jan, 2026 | 17:39
Updated-03 Feb, 2026 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Incorrect Authorization Allows Administrator Password Change

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain an authorization flaw in the user management API that allows a low-privileged authenticated user to change the administrator account password. By sending a crafted request directly to the backend endpoint, an attacker can bypass role-based restrictions enforced by the web interface and obtain full administrative privileges.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-863
Incorrect Authorization
CVE-2026-24107
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.86%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 15:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Failure to validate the value of `usbPartitionName`, which is directly used in `doSystemCmd`, may lead to critical command injection vulnerabilities.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-94