Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-12274

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Oct, 2025 | 12:32
Updated At-24 Feb, 2026 | 07:11
Rejected At-
Credits

Tenda CH22 P2pListFilter fromP2pListFilter buffer overflow

A security vulnerability has been detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Oct, 2025 | 12:32
Updated At:24 Feb, 2026 | 07:11
Rejected At:
â–¼CVE Numbering Authority (CNA)
Tenda CH22 P2pListFilter fromP2pListFilter buffer overflow

A security vulnerability has been detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
CH22
CPEs
  • cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
Versions
Affected
  • 1.0.0.1
Problem Types
TypeCWE IDDescription
CWECWE-120Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-120
Description: Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
hhsw34 (VulDB User)
Timeline
EventDate
Advisory disclosed2025-10-26 00:00:00
VulDB entry created2025-10-26 02:00:00
VulDB entry last update2025-10-27 23:42:37
Event: Advisory disclosed
Date: 2025-10-26 00:00:00
Event: VulDB entry created
Date: 2025-10-26 02:00:00
Event: VulDB entry last update
Date: 2025-10-27 23:42:37
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.329946
vdb-entry
technical-description
https://vuldb.com/?ctiid.329946
signature
permissions-required
https://vuldb.com/?submit.674165
third-party-advisory
https://github.com/QIU-DIE/CVE/issues/23
broken-link
exploit
issue-tracking
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.329946
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.329946
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.674165
Resource:
third-party-advisory
Hyperlink: https://github.com/QIU-DIE/CVE/issues/23
Resource:
broken-link
exploit
issue-tracking
Hyperlink: https://www.tenda.com.cn/
Resource:
product
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/QIU-DIE/CVE/issues/23
exploit
Hyperlink: https://github.com/QIU-DIE/CVE/issues/23
Resource:
exploit
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Oct, 2025 | 13:15
Updated At:28 Oct, 2025 | 02:06

A security vulnerability has been detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ch22_firmware>>1.0.0.1
cpe:2.3:o:tenda:ch22_firmware:1.0.0.1:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ch22>>-
cpe:2.3:h:tenda:ch22:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarycna@vuldb.com
CWE-120Primarycna@vuldb.com
CWE ID: CWE-119
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-120
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/QIU-DIE/CVE/issues/23cna@vuldb.com
Exploit
Issue Tracking
https://vuldb.com/?ctiid.329946cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.329946cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.674165cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
https://github.com/QIU-DIE/CVE/issues/23134c704f-9b21-4f2e-91b3-4a467353bcc0
Exploit
Issue Tracking
Hyperlink: https://github.com/QIU-DIE/CVE/issues/23
Source: cna@vuldb.com
Resource:
Exploit
Issue Tracking
Hyperlink: https://vuldb.com/?ctiid.329946
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.329946
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.674165
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product
Hyperlink: https://github.com/QIU-DIE/CVE/issues/23
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Resource:
Exploit
Issue Tracking

Change History

0
Information is not available yet

Similar CVEs

1378Records found

CVE-2024-11061
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.30% / 53.37%
||
7 Day CHG~0.00%
Published-11 Nov, 2024 | 00:31
Updated-13 Nov, 2024 | 23:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow

A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11248
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.00% / 76.76%
||
7 Day CHG~0.00%
Published-15 Nov, 2024 | 17:00
Updated-19 Nov, 2024 | 21:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11056
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.21%
||
7 Day CHG~0.00%
Published-10 Nov, 2024 | 16:31
Updated-14 Nov, 2024 | 15:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-10120
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.58%
||
7 Day CHG~0.00%
Published-09 Sep, 2025 | 01:32
Updated-10 Sep, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 GetParentControlInfo strcpy buffer overflow

A vulnerability was detected in Tenda AC20 up to 16.03.08.12. The impacted element is the function strcpy of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in buffer overflow. The attack may be performed from remote. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-0349
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.45% / 63.49%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 10:31
Updated-22 Mar, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7585
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.31% / 54.08%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 17:00
Updated-11 Sep, 2024 | 19:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow

A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-7613
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 62.87%
||
7 Day CHG~0.00%
Published-08 Aug, 2024 | 22:00
Updated-21 Aug, 2024 | 18:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 GstDhcpSetSer fromGstDhcpSetSer buffer overflow

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4368
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.33% / 79.74%
||
7 Day CHG+0.86%
Published-06 May, 2025 | 15:31
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 MtuSetMacWan formGetRouterStatus buffer overflow

A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-14656
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.90%
||
7 Day CHG~0.00%
Published-14 Dec, 2025 | 11:02
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 openSchedWifi httpd buffer overflow

A weakness has been identified in Tenda AC20 16.03.08.12. This affects the function httpd of the file /goform/openSchedWifi. Executing a manipulation of the argument schedStartTime/schedEndTime can lead to buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20_firmwareac20AC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11121
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.40% / 60.25%
||
7 Day CHG-0.63%
Published-28 Sep, 2025 | 21:32
Updated-03 Oct, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 AdvSetLanip command injection

A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10442
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.36% / 58.16%
||
7 Day CHG~0.00%
Published-15 Sep, 2025 | 11:02
Updated-19 Sep, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9/AC15 exeCommand formexeCommand os command injection

A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac9_firmwareac9ac15AC9AC15
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-8224
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.14%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 23:00
Updated-13 Dec, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G3 setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g3g3_firmwareG3g3_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8227
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 62.96%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:00
Updated-29 Aug, 2024 | 00:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O1 DhcpSetSer fromDhcpSetSer stack-based overflow

A vulnerability was found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o1o1_firmwareO1o1_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8229
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.69% / 71.59%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:31
Updated-29 Aug, 2024 | 00:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O6 operateMacFilter frommacFilterModify stack-based overflow

A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o6_firmwareo6O6o6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7615
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 62.87%
||
7 Day CHG~0.00%
Published-08 Aug, 2024 | 22:31
Updated-21 Aug, 2024 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 fromSafeUrlFilter stack-based overflow

A vulnerability was found in Tenda FH1206 1.2.0.8. It has been declared as critical. Affected by this vulnerability is the function fromSafeClientFilter/fromSafeMacFilter/fromSafeUrlFilter. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7707
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.60% / 69.16%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-22 Aug, 2024 | 13:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow

A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8231
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.92% / 75.70%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 01:00
Updated-16 Oct, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O6 setPortForward fromVirtualSet stack-based overflow

A vulnerability classified as critical has been found in Tenda O6 1.0.0.7(2054). Affected is the function fromVirtualSet of the file /goform/setPortForward. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o6_firmwareo6O6o6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7581
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.61% / 69.51%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 15:00
Updated-07 Aug, 2024 | 19:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow

A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8228
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.86% / 74.84%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:00
Updated-29 Aug, 2024 | 00:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O5 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O5 1.0.0.8(5017). It has been classified as critical. This affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o5_firmwareo5O5o5_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8226
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 62.96%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 23:31
Updated-29 Aug, 2024 | 00:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O1 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda O1 1.0.0.7(10648) and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o1o1_firmwareO1o1_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7151
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.55%
||
7 Day CHG~0.00%
Published-27 Jul, 2024 | 20:00
Updated-01 Oct, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setMacFilter fromMacFilterSet stack-based overflow

A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6962
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 47.79%
||
7 Day CHG~0.00%
Published-21 Jul, 2024 | 23:31
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 formQosSet stack-based overflow

A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O3o3v2
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6965
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.58% / 68.56%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 01:31
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 fromVirtualSet stack-based overflow

A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O3o3v2o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6964
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 47.79%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 01:00
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 fromDhcpSetSer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda O3 1.0.0.10. Affected is the function fromDhcpSetSer. The manipulation of the argument dhcpEn/startIP/endIP/preDNS/altDNS/mask/gateway leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272118 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O303v2.0_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6963
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.78% / 73.45%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 00:00
Updated-01 Aug, 2024 | 21:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 formexeCommand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3o3_firmware1.0.0.10\(2478\)O3o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7152
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.55%
||
7 Day CHG~0.00%
Published-27 Jul, 2024 | 21:00
Updated-01 Nov, 2024 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3o3v2_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6189
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.59% / 68.88%
||
7 Day CHG~0.00%
Published-20 Jun, 2024 | 14:00
Updated-01 Nov, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-57704
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-4.6||MEDIUM
EPSS-0.37% / 58.71%
||
7 Day CHG+0.18%
Published-16 Jan, 2025 | 00:00
Updated-17 Mar, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40800
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.55%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2024-50854
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.36%
||
7 Day CHG+0.10%
Published-13 Nov, 2024 | 00:00
Updated-14 Mar, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3_firmwareg3n/ag3
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-33530
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.98% / 76.62%
||
7 Day CHG-0.06%
Published-06 Jun, 2023 | 00:00
Updated-08 Jan, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability in the Tenda G103 Gigabit GPON Terminal with firmware version V1.0.0.5. If an attacker gains web management privileges, they can inject commands gaining shell privileges.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g103g103_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-4241
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.68%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:00
Updated-27 Jan, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_auto stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-24440
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-8.7||HIGH
EPSS-0.05% / 15.49%
||
7 Day CHG+0.01%
Published-26 Jan, 2026 | 17:38
Updated-28 Jan, 2026 | 19:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Allows Password Changes Without Verifying Current Password

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-620
Unverified Password Change
CVE-2024-4250
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.15% / 35.12%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 12:00
Updated-27 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4168
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.05%
||
7 Day CHG-0.22%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4260F0 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40801
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.19%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2024-4066
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.88%
||
7 Day CHG-0.28%
Published-23 Apr, 2024 | 21:00
Updated-21 Jan, 2025 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3874
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.38% / 59.12%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 15:31
Updated-01 Aug, 2024 | 20:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-W20Ew20e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-63835
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.27% / 49.96%
||
7 Day CHG~0.00%
Published-10 Nov, 2025 | 00:00
Updated-18 Nov, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18ac18_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5763
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.88% / 75.06%
||
7 Day CHG+0.11%
Published-06 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CP3 apollo sub_F3C8C command injection

A vulnerability has been found in Tenda CP3 11.10.00.2311090948 and classified as critical. Affected by this vulnerability is the function sub_F3C8C of the file apollo. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-cp3cp3_firmwareCP3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-32299
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.01%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1203fh1203_firmwaren/afh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-45977
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-17.98% / 95.06%
||
7 Day CHG~0.00%
Published-12 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 V22.03.01.21_CN was found to have a command injection vulnerability via /goform/setMacFilterCfg function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-45781
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.34%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 00:00
Updated-03 Sep, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1803_firmwareax1803n/aax1803_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2812
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.64% / 89.14%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WriteFacMac formWriteFacMac os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2893
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.45%
||
7 Day CHG-0.02%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2813
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 67.11%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-23 Aug, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2581
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.53%
||
7 Day CHG-0.24%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2485
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.91%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 07:00
Updated-13 Feb, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2489
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.47%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-10 Apr, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetNetControlList formSetQosBand stack-based overflow

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10283
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.58%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 15:00
Updated-01 Nov, 2024 | 14:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • ...
  • 5
  • 6
  • 7
  • ...
  • 27
  • 28
  • Next
Details not found