Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-11 Mar, 2025 | 09:48
Updated At-11 Mar, 2025 | 14:29
Rejected At-
Credits

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:11 Mar, 2025 | 09:48
Updated At:11 Mar, 2025 | 14:29
Rejected At:
â–¼CVE Numbering Authority (CNA)

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Affected Products
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V14.3
Default Status
unknown
Versions
Affected
  • From 0 before V14.3.0.13 (custom)
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V2312
Default Status
unknown
Versions
Affected
  • From 0 before V2312.0009 (custom)
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V2406
Default Status
unknown
Versions
Affected
  • From 0 before V2406.0007 (custom)
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V2412
Default Status
unknown
Versions
Affected
  • From 0 before V2412.0002 (custom)
Vendor
Siemens AGSiemens
Product
Tecnomatix Plant Simulation V2302
Default Status
unknown
Versions
Affected
  • From 0 before V2302.0021 (custom)
Vendor
Siemens AGSiemens
Product
Tecnomatix Plant Simulation V2404
Default Status
unknown
Versions
Affected
  • From 0 before V2404.0010 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-416CWE-416: Use After Free
Type: CWE
CWE ID: CWE-416
Description: CWE-416: Use After Free
Metrics
VersionBase scoreBase severityVector
3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
4.07.3HIGH
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Version: 4.0
Base score: 7.3
Base severity: HIGH
Vector:
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-050438.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-050438.html
Resource: N/A
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:11 Mar, 2025 | 10:15
Updated At:23 Sep, 2025 | 15:28

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.3HIGH
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 7.3
Base severity: HIGH
Vector:
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>teamcenter_visualization>>Versions from 14.0.0(inclusive) to 14.3.0.13(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 2312.0(inclusive) to 2312.0009(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 2406.0(inclusive) to 2406.0007(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 2412.0(inclusive) to 2412.0002(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>tecnomatix_plant_simulation>>Versions from 2302.0(inclusive) to 2302.0021(exclusive)
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>tecnomatix_plant_simulation>>Versions from 2404.0(inclusive) to 2404.0010(exclusive)
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-416Primaryproductcert@siemens.com
CWE ID: CWE-416
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-050438.htmlproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-050438.html
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1347Records found

CVE-2021-42028
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 12.80%
||
7 Day CHG~0.00%
Published-04 Jan, 2024 | 11:20
Updated-17 Jun, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)

Action-Not Available
Vendor-Siemens AGSiemens Medical Solutions USA, Inc.
Product-syngo_fastviewsyngo fastView
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-23716
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.01% / 0.93%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 09:58
Updated-11 Feb, 2026 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_nastransimcenter_femapSimcenter NastranSimcenter Femap
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-40367
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.05% / 16.19%
||
7 Day CHG~0.00%
Published-04 Jan, 2024 | 11:20
Updated-17 Jun, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)

Action-Not Available
Vendor-Siemens AGSiemens Medical Solutions USA, Inc.
Product-syngo_fastviewsyngo fastView
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-39134
Matching Score-8
Assigner-GitHub, Inc.
ShareView Details
Matching Score-8
Assigner-GitHub, Inc.
CVSS Score-8.2||HIGH
EPSS-0.72% / 72.97%
||
7 Day CHG~0.00%
Published-31 Aug, 2021 | 16:55
Updated-04 Aug, 2024 | 01:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
UNIX Symbolic Link (Symlink) Following in @npmcli/arborist

`@npmcli/arborist`, the library that calculates dependency trees and manages the `node_modules` folder hierarchy for the npm command line interface, aims to guarantee that package dependency contracts will be met, and the extraction of package contents will always be performed into the expected folder. This is, in part, accomplished by resolving dependency specifiers defined in `package.json` manifests for dependencies with a specific name, and nesting folders to resolve conflicting dependencies. When multiple dependencies differ only in the case of their name, Arborist's internal data structure saw them as separate items that could coexist within the same level in the `node_modules` hierarchy. However, on case-insensitive file systems (such as macOS and Windows), this is not the case. Combined with a symlink dependency such as `file:/some/path`, this allowed an attacker to create a situation in which arbitrary contents could be written to any location on the filesystem. For example, a package `pwn-a` could define a dependency in their `package.json` file such as `"foo": "file:/some/path"`. Another package, `pwn-b` could define a dependency such as `FOO: "file:foo.tgz"`. On case-insensitive file systems, if `pwn-a` was installed, and then `pwn-b` was installed afterwards, the contents of `foo.tgz` would be written to `/some/path`, and any existing contents of `/some/path` would be removed. Anyone using npm v7.20.6 or earlier on a case-insensitive filesystem is potentially affected. This is patched in @npmcli/arborist 2.8.2 which is included in npm v7.20.7 and above.

Action-Not Available
Vendor-npmjsnpmOracle CorporationSiemens AG
Product-sinec_infrastructure_network_servicesarboristnpmgraalvmarborist
CWE ID-CWE-61
UNIX Symbolic Link (Symlink) Following
CWE ID-CWE-178
Improper Handling of Case Sensitivity
CVE-2023-44084
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.17% / 37.67%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-125
Out-of-bounds Read
CVE-2025-32454
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.06% / 18.87%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-23 Sep, 2025 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationtecnomatix_plant_simulationTeamcenter Visualization V2312Teamcenter Visualization V2406Teamcenter Visualization V14.3Tecnomatix Plant Simulation V2404Teamcenter Visualization V2412
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-38405
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.08% / 23.78%
||
7 Day CHG~0.00%
Published-21 Nov, 2023 | 18:19
Updated-04 Aug, 2024 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Siemens Solid Edge, JT2Go, and Teamcenter Visualization Improper Restriction of Operations within the Bounds of a Memory Buffer

The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-30795
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.13% / 32.30%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt_openparasolidjt_utilitiesParasolid V34.0Parasolid V35.1JT UtilitiesParasolid V35.0JT OpenParasolid V34.1
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-34311
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 62.37%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13352)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2018-4858
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.06%
||
7 Day CHG~0.00%
Published-09 Jul, 2018 | 19:00
Updated-16 Sep, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-ec_61850_system_configurator_firmwaresicam_sccdigsi_5_firmwaredigsi_4_firmwaresicam_scc_firmwaresicam_pq_analyzersicam_pq_analyzer_firmwaredigsi_4sicam_pas\/pqsdigsi_5ec_61850_system_configuratorIEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC
CWE ID-CWE-284
Improper Access Control
CVE-2025-30033
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.03% / 9.06%
||
7 Day CHG+0.02%
Published-12 Aug, 2025 | 11:16
Updated-10 Mar, 2026 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

Action-Not Available
Vendor-Siemens AG
Product-Siemens Network Planner (SINETPLAN)SIMATIC PCS 7 Advanced Process Functions V2.1SIMATIC Process Historian 2022SIMIT Simulation PlatformSIMATIC WinCC V8.1SIMATIC STEP 7 CFC V20SIMATIC PCS 7 Industry Library V10.0TIA Portal Cloud ConnectorSIMATIC Logon V1.6SINEMA Remote Connect ClientSIMATIC PDM V9.2Standard PID CTRL ToolSIMATIC WinCC Runtime Professional V20SIMIT Rapid TesterCreate MyConfig (CMC)SINAMICS Startdrive V19SIMATIC PCS 7 Advanced Process Graphics V10.0SINAMICS Startdrive V20SIMATIC Automation Tool SDK WindowsSIMATIC MTP Integrator V1.xSIMATIC STEP 7 V5.7CEMAT V10.0SIMATIC WinCC Unified SequenceOpenPCS 7 V10.0SIMATIC eaSie Core PackageTIA Project-ServerSIMATIC MTP CREATOR V2.xSIMATIC S7-Fail-safe Configuration Tool (S7-FCT)SIMATIC Automation ToolSIMATIC S7 F Systems V6.3SIMATIC WinCC Runtime ProfessionalTotally Integrated Automation Portal (TIA Portal) V19SIMATIC MTP Integrator V2.xWinCC Panel Image SetupSIMATIC ProSave V17SIMATIC WinCC Visualization Architect (SiVArc) V17SIMATIC PCS neo V5.0SIMATIC S7-1500 Software Controller V3SIMATIC Route Control V9.1SIMATIC ProSave V18SIMATIC NET PC Software V20Modular PID CTRL ToolSIMATIC Energy Suite V18SIMATIC D7-SYSSIMATIC PCS 7 Industry Library V9.0SIMATIC NET PC Software V19SIMATIC Process Function Library (PFL) V4.0SINAMICS Startdrive V18MultiFieldbus Configuration Tool (MFCT)FM Configuration PackageSIMATIC Logon V2.0SIMATIC eaSie Workflow SkillsSIMATIC S7-PLCSIM V20CP PtP Param configuring interfaceSIMATIC NET PC Software V17SIMATIC PCS 7 PowerControlSIMATIC MTP CREATOR V4.xSIMATIC BATCH V10.0SIMATIC PCS 7 V10.0SIMATIC eaSie Document SkillsSIMATIC WinCC Visualization Architect (SiVArc) V19Automation License Manager V6.0SIMATIC ProSave V20SIMATIC PCS 7 Advanced Process Faceplates V9.1SIMATIC Process Historian 2020SIMATIC Energy Suite V19SIMATIC PCS 7 Logic Matrix V10.0SIMATIC PCS neo V6.0SIMATIC S7-PLCSIM V17SIMATIC S7 F Systems V6.4SIMATIC S7-PLCSIM AdvancedTotally Integrated Automation Portal (TIA Portal) V17SIMATIC MTP CREATOR V5.xSIMATIC WinCC Runtime AdvancedSIMATIC S7-PLCSIM V18SIMATIC ProSave V19SIMATIC Energy Suite V17SIMATIC MTP CREATOR V3.xEnergy Support Library (EnSL)SIMATIC PCS 7 Standard Chemical Library V10.0SITRANSSIMATIC Management AgentSIMATIC PCS 7 Advanced Process Functions V2.2SIMATIC ODK 1500SSIMATIC WinCC Unified PC Runtime V19SIMATIC BATCH V9.1TIA Portal Test Suite V19SIMATIC PCS 7 MPC ConfiguratorSIMATIC STEP 7 CFC V19OpenPCS 7 V9.1SIMATIC PCS 7 Basis Faceplates V9.1SIMATIC WinCC V8.0TIA AdministratorAutomation License Manager V6.2SIMATIC S7-1500 Software Controller V2SIMATIC Control Function Library (CFL) V1.xSIMATIC PDM Maintenance Station V5.0SIMATIC WinCC Unified Line CoordinationSIMATIC PCS 7 Basis Library V9.1SIMATIC Control Function Library (CFL) V2.xSIMATIC WinCC V7.5SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0SIMATIC PCS 7 Standard Chemical Library V9.1SIMATIC WinCC flexible ESSIMATIC Route Control V10.0SIMATIC WinCC Visualization Architect (SiVArc) V18TIA Portal Test Suite V20SIMATIC S7-PLCSIM V19SIMATIC NET PC Software V18SINAMICS Startdrive V17Totally Integrated Automation Portal (TIA Portal) V18SIMATIC Safety MatrixTIA Project-Server V17SIMATIC WinCC Unified PC Runtime V20Totally Integrated Automation Portal (TIA Portal) V20SIMATIC WinCC TeleControlSINEC NMSSIMATIC PCS 7/OPEN OS V9.1SIMATIC Process Historian 2024TIA Portal Test Suite V18SIMATIC WinCC Visualization Architect (SiVArc) V20SIMATIC PDM V9.3SIMATIC PCS 7 Basis Library V10.0SIMATIC WinCC Unified PC Runtime V18SIMATIC Control Function Library (CFL) V4.xSIMATIC PCS 7 Logic Matrix V9.1SIMATIC PCS 7 TeleControlSIMATIC PCS 7 V9.1SIMATIC TargetSIMATIC Management ConsoleSIMATIC S7-PCTSIMATIC NET PC Software V16TIA Portal Test Suite V17SIMATIC PCS 7 Advanced Process Library V9.1TeleControl Server Basic V3.1SIMATIC eaSie PCS 7 Skill PackageSIMATIC Control Function Library (CFL) V3.xSIMATIC PCS 7 Advanced Process Graphics V9.1SIMATIC PCS 7 Industry Library V9.1
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2023-30796
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.11% / 29.66%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 22:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJT OpenJT Utilities
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-30900
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 26.57%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Xpedition Layout Browser (All versions < VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-xpedition_layout_browserXpedition Layout Browser
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-37180
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 60.01%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2021_firmwareSolid Edge SE2021
CWE ID-CWE-824
Access of Uninitialized Pointer
CVE-2023-29053
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-11 Apr, 2023 | 09:03
Updated-26 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt_open_toolkitjt_utilitiesJT OpenJT Utilities
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-44086
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.17% / 37.67%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-54095
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.13% / 33.20%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 13:54
Updated-04 Mar, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 10). The affected application is vulnerable to integer underflow vulnerability which can be triggered while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2024Solid Edge SE2024
CWE ID-CWE-191
Integer Underflow (Wrap or Wraparound)
CVE-2024-24920
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.38%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-07 Nov, 2024 | 19:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21710)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-27438
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.12% / 30.95%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-23 Sep, 2025 | 15:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationtecnomatix_plant_simulationTeamcenter Visualization V2406Teamcenter Visualization V2412Teamcenter Visualization V2312Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3Tecnomatix Plant Simulation V2302
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-24555
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 9.82%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-02 Aug, 2024 | 11:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2022solid_edge_se2023Solid Edge SE2022Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-54093
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.17% / 37.53%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 13:54
Updated-10 Dec, 2024 | 17:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted ASM files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-Solid Edge SE2024
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2021-27381
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 62.37%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27401
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20308, ZDI-CAN-20345)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27404
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.46% / 64.79%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20433)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27399
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.13% / 31.97%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 17:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20299, ZDI-CAN-20346)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-53242
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.17% / 38.28%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 13:54
Updated-24 Sep, 2025 | 19:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationtecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27405
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20432)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27403
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains a memory corruption vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20303, ZDI-CAN-20348)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-25175
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.11% / 29.98%
||
7 Day CHG~0.00%
Published-13 Mar, 2025 | 09:07
Updated-19 Aug, 2025 | 17:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2406Simcenter Femap V2401
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-27398
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:31
Updated-27 Feb, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20304)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27400
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20300)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-27402
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-27406
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 16:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20449)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-26293
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.12% / 30.49%
||
7 Day CHG~0.00%
Published-11 Apr, 2023 | 09:03
Updated-25 Nov, 2024 | 21:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.

Action-Not Available
Vendor-Siemens AG
Product-tia_portalTotally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V15Totally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V18
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-24996
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:37
Updated-19 Mar, 2025 | 15:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19818)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-34772
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.18% / 39.19%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:03
Updated-02 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-Solid Edgesolid_edge
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-54094
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.17% / 37.53%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 13:54
Updated-04 Mar, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2024Solid Edge SE2024
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24982
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19804)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24995
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:37
Updated-19 Mar, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19817)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24985
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 18:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19807)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24558
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 19:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2022Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-24561
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 19:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2022Solid Edge SE2023
CWE ID-CWE-824
Access of Uninitialized Pointer
CVE-2023-24552
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-02 Aug, 2024 | 11:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2022solid_edge_se2023Solid Edge SE2022Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-25140
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.05% / 16.49%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:37
Updated-19 Mar, 2025 | 18:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150), Solid Edge SE2022 (All versions < V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-parasolidsolid_edgeParasolid V34.0Solid Edge SE2022Parasolid V34.1Parasolid V35.1Parasolid V35.0
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-53041
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 34.32%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 13:54
Updated-24 Sep, 2025 | 19:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationtecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-23399
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.12% / 30.95%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-23 Sep, 2025 | 15:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationtecnomatix_plant_simulationTeamcenter Visualization V2406Teamcenter Visualization V2412Teamcenter Visualization V2312Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3Tecnomatix Plant Simulation V2302
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-24992
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:37
Updated-18 Mar, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19814)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24553
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2022Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-24988
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 30.80%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-19 Mar, 2025 | 19:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19810)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-24981
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 18:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19791)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 26
  • 27
  • Next
Details not found