CVE-2025-26390

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-13 May, 2025 | 09:38
Updated At-13 May, 2025 | 18:56
Rejected At-
Credits

A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:13 May, 2025 | 09:38
Updated At:13 May, 2025 | 18:56
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user.

Affected Products
Vendor
Siemens AGSiemens
Product
OZW672
Default Status
unknown
Versions
Affected
  • From 0 before V6.0 (custom)
Vendor
Siemens AGSiemens
Product
OZW772
Default Status
unknown
Versions
Affected
  • From 0 before V6.0 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-89CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Type: CWE
CWE ID: CWE-89
Description: CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Metrics
VersionBase scoreBase severityVector
3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.09.3CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 4.0
Base score: 9.3
Base severity: CRITICAL
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-047424.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-047424.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:13 May, 2025 | 10:15
Updated At:13 May, 2025 | 19:35

A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.09.3CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 9.3
Base severity: CRITICAL
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-89Primaryproductcert@siemens.com
CWE ID: CWE-89
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-047424.htmlproductcert@siemens.com
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-047424.html
Source: productcert@siemens.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

5165Records found

CVE-2024-32740
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.63% / 69.42%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-20 Aug, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cn_4100_firmwaresimatic_cn_4100SIMATIC CN 4100simatic_cn_4100
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-24281
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-0.72% / 71.61%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 00:00
Updated-21 Apr, 2025 | 13:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_network_management_systemSINEC NMSSINEMA Server V14
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-27411
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.57% / 67.61%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an authenticated remote attackers to execute arbitrary SQL queries on the server database and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-15792
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.21% / 43.97%
||
7 Day CHG~0.00%
Published-15 Oct, 2020 | 18:45
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo Insight (All versions). The web service does not properly apply input validation for some query parameters in a reserved area. This could allow an authenticated attacker to retrieve data via a content-based blind SQL injection attack.

Action-Not Available
Vendor-Siemens AG
Product-desigo_insightDesigo Insight
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-27940
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.96% / 75.60%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow any authenticated user to send arbitrary SQL commands to the SQL server. An attacker could use this vulnerability to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-27941
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.29% / 78.86%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected client systems do not properly sanitize input data before sending it to the SQL server. An attacker could use this vulnerability to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-37197
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.72% / 71.65%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS V10.3COMOS V10.2COMOS V10.4
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32846
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33732
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-1.25% / 78.48%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33734
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.15% / 83.59%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33730
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.15% / 83.59%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33736
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-1.06% / 76.78%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33731
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.15% / 83.59%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-46097
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-6.3||MEDIUM
EPSS-0.10% / 28.51%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:04
Updated-08 Jan, 2025 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.

Action-Not Available
Vendor-Siemens AG
Product-simatic_pcs_neoSIMATIC PCS neo
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-19292
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.55% / 67.05%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-7577
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.80% / 73.06%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to.

Action-Not Available
Vendor-Siemens AG
Product-opcenter_execution_coreCamstar Enterprise PlatformOpcenter Execution Core
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-40735
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.94%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected devices are vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32849
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32844
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32822
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'DeleteProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32852
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32861
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32856
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32854
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32835
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32870
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32827
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ActivateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32834
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32860
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32869
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.79%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32868
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.79%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32859
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32867
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32850
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32824
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32857
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32855
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32836
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32838
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32841
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32832
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32826
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32843
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32842
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32865
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32848
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32851
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32871
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32872
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:39
Updated-19 Aug, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32845
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.51%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 103
  • 104
  • Next
Details not found