KUNBUS PiCtory versions 2.5.0 through 2.11.1 have an authentication bypass vulnerability where a remote attacker can bypass authentication to get access due to a path traversal.
CrushFTP 10 before 10.8.4 and 11 before 11.3.1 allows authentication bypass and takeover of the crushadmin account (unless a DMZ proxy instance is used), as exploited in the wild in March and April 2025, aka "Unauthenticated HTTP(S) port access." A race condition exists in the AWS4-HMAC (compatible with S3) authorization method of the HTTP component of the FTP server. The server first verifies the existence of the user by performing a call to login_user_pass() with no password requirement. This will authenticate the session through the HMAC verification process and up until the server checks for user verification once more. The vulnerability can be further stabilized, eliminating the need for successfully triggering a race condition, by sending a mangled AWS4-HMAC header. By providing only the username and a following slash (/), the server will successfully find a username, which triggers the successful anypass authentication process, but the server will fail to find the expected SignedHeaders entry, resulting in an index-out-of-bounds error that stops the code from reaching the session cleanup. Together, these issues make it trivial to authenticate as any known or guessable user (e.g., crushadmin), and can lead to a full compromise of the system by obtaining an administrative account.
User authentication with username and password credentials is ineffective in OpenText (Micro Focus) Visual COBOL, COBOL Server, Enterprise Developer, and Enterprise Server (including product variants such as Enterprise Test Server), versions 7.0 patch updates 19 and 20, 8.0 patch updates 8 and 9, and 9.0 patch update 1, when LDAP-based authentication is used with certain configurations. When the vulnerability is active, authentication succeeds with any valid username, regardless of whether the password is correct; it may also succeed with an invalid username (and any password). This allows an attacker with access to the product to impersonate any user. Mitigations: The issue is corrected in the upcoming patch update for each affected product. Product overlays and workaround instructions are available through OpenText Support. The vulnerable configurations are believed to be uncommon. Administrators can test for the vulnerability in their installations by attempting to sign on to a Visual COBOL or Enterprise Server component such as ESCWA using a valid username and incorrect password.
Authentication Bypass by Primary Weakness vulnerability in Swoop 1-Click Login: Passwordless Authentication allows Authentication Bypass.This issue affects 1-Click Login: Passwordless Authentication: 1.4.5.
A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.