Beck IPC GmbH IPC@CHIP telnet service does not delay or disconnect users from the service when bad passwords are entered, which makes it easier for remote attackers to conduct brute force password guessing attacks.
The telnet server for 3Com hardware such as PS40 SuperStack II does not delay or disconnect remote attackers who provide an incorrect username or password, which makes it easier to break into the server via brute force password guessing.
Lightwave ConsoleServer 3200 does not disconnect users after unsuccessful login attempts, which could allow remote attackers to conduct brute force password guessing.
In Eclipse GlassFish version 7.0.16 or earlier it is possible to perform Login Brute Force attacks as there is no limitation in the number of failed login attempts.
Logsign Unified SecOps Platform Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Logsign Unified SecOps Platform. Authentication is not required to exploit this vulnerability. The specific flaw exists within the password reset mechanism. The issue results from the lack of restriction of excessive authentication attempts. An attacker can leverage this vulnerability to reset a user's password and bypass authentication on the system. Was ZDI-CAN-24164.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
Argo CD is a declarative, GitOps continuous delivery tool for Kubernetes. Prior to versions 2.8.13, 2.9.9, and 2.10.4, an attacker can exploit a chain of vulnerabilities, including a Denial of Service (DoS) flaw and in-memory data storage weakness, to effectively bypass the application's brute force login protection. This is a critical security vulnerability that allows attackers to bypass the brute force login protection mechanism. Not only can they crash the service affecting all users, but they can also make unlimited login attempts, increasing the risk of account compromise. Versions 2.8.13, 2.9.9, and 2.10.4 contain a patch for this issue.
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the login form.
Dell EMC XtremIO versions prior to X2 6.4.0-22 contain a bruteforce vulnerability. A remote unauthenticated attacker can potentially exploit this vulnerability and gain access to an admin account.
Dell EMC PowerStore, contain(s) an Improper Restriction of Excessive Authentication Attempts Vulnerability in PowerStore Manager GUI. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to password brute-forcing. Account takeover is possible if weak passwords are used by users.
This vulnerability exists in the Wave 2.0 due to missing restrictions for excessive failed authentication attempts on its API based login. A remote attacker could exploit this vulnerability by conducting a brute force attack against legitimate user OTP, MPIN or password, which could lead to gain unauthorized access and compromise other user accounts.
An issue in TopIDP3000 Topsec Operating System tos_3.3.005.665b.15_smpidp allows attackers to perform a brute-force attack via a crafted session_id cookie.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
An issue was discovered on Samsung mobile devices with O(8.x), P(9.0), and Q(10.0) (Exynos7885, Exynos8895, and Exynos9810 chipsets) software. The Gatekeeper trustlet allows a brute-force attack on the screen lock password. The Samsung ID is SVE-2019-14575 (January 2020).
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
Dell EMC ECS versions prior to 3.4.0.0 contain an improper restriction of excessive authentication attempts vulnerability. An unauthenticated remote attacker may potentially perform a password brute-force attack to gain access to the targeted accounts.
Dell Unity, Dell UnityVSA, and Dell Unity XT versions before 5.2.0.0.5.173 do not restrict excessive authentication attempts in Unisphere GUI. A remote unauthenticated attacker may potentially exploit this vulnerability to brute-force passwords and gain access to the system as the victim. Account takeover is possible if weak passwords are used by users.
The Phonemes mode in Pwgen 2.06 generates predictable passwords, which makes it easier for context-dependent attackers to guess the password via a brute-force attack.
This vulnerability exists in Apex Softcell LD Geo due to missing restrictions for excessive failed authentication attempts on its API based login. A remote attacker could exploit this vulnerability by conducting a brute force attack on login OTP, which could lead to gain unauthorized access to other user accounts.
In Omron PLC CS series, all versions, Omron PLC CJ series, all versions, and Omron PLC NJ series, all versions, the software does not implement sufficient measures to prevent multiple failed authentication attempts within in a short time frame, making it more susceptible to brute force attacks.
A vulnerability classified as critical was found in Telecommunication Software SAMwin Contact Center Suite 5.1. This vulnerability affects the function passwordScramble in the library SAMwinLIBVB.dll of the component Password Handler. Incorrect implementation of a hashing function leads to predictable authentication possibilities. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.
bl-kernel/security.class.php in Bludit 3.9.2 allows attackers to bypass a brute-force protection mechanism by using many different forged X-Forwarded-For or Client-IP HTTP headers.
This vulnerability exists in Reedos aiM-Star version 2.0.1 due to missing restrictions for excessive failed authentication attempts on its API based login. A remote attacker could exploit this vulnerability by conducting a brute force attack against legitimate user passwords, which could lead to gain unauthorized access and compromise other user accounts.
EuroTel ETL3100 versions v01c01 and v01x37 does not limit the number of attempts to guess administrative credentials in remote password attacks to gain full control of the system.
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. There is no bruteforce protection (e.g., lockout) established. An attacker might be able to bruteforce the password to authenticate on the device.
Lack of protection against brute force attacks in M-Files Server before 23.12.13205.0 allows an attacker unlimited authentication attempts, potentially compromising targeted M-Files user accounts by guessing passwords.
User login brute force protection functionality bypass
An issue was discovered on Samsung mobile devices with O(8.x) (with TEEGRIS) software. The Gatekeeper Trustlet allows a brute-force attack on user credentials. The Samsung ID is SVE-2020-16908 (June 2020).
OX App Suite 7.10.1 to 7.10.3 has improper input validation for rate limits with a crafted User-Agent header, spoofed vacation notices, and /apps/load memory consumption.
Pluck CMS 4.7.18 does not restrict failed login attempts, allowing attackers to execute a brute force attack.
In Sorcery before 0.15.0, there is a brute force vulnerability when using password authentication via Sorcery. The brute force protection submodule will prevent a brute force attack for the defined lockout period, but once expired, protection will not be re-enabled until a user or malicious actor logs in successfully. This does not affect users that do not use the built-in brute force protection submodule, nor users that use permanent account lockout. This has been patched in 0.15.0.
A vulnerability was found in Thecosy IceCMS 2.0.1. It has been classified as problematic. Affected is an unknown function of the file /login of the component Captcha Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-247884.
Improper Restriction of Excessive Authentication Attempts vulnerability in upKeeper Solutions product upKeeper Manager allows Authentication Abuse.This issue affects upKeeper Manager: through 5.1.9.
Improper Restriction of Excessive Authentication Attempts vulnerability in upKeeper Solutions product upKeeper Manager allows Authentication Abuse.This issue affects upKeeper Manager: through 5.1.9.
A vulnerability in Kaiten version 57.131.12 and earlier allows attackers to bypass the PIN code authentication mechanism. The application requires users to input a 6-digit PIN code sent to their email for authorization after entering their login credentials. However, the request limiting mechanism can be easily bypassed, enabling attackers to perform a brute force attack to guess the correct PIN and gain unauthorized access to the application.
Ricoh SP C250DN 1.05 devices have an Authentication Method Vulnerable to Brute Force Attacks. Some Ricoh printers did not implement account lockout. Therefore, it was possible to obtain the local account credentials by brute force.
The authentication implementation on the xArm controller has very low entropy, making it vulnerable to a brute-force attack. There is no mechanism in place to mitigate or lockout automated attempts to gain access.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
Umanni RH 1.0 does not limit the number of authentication attempts. An unauthenticated user may exploit this vulnerability to launch a brute-force authentication attack against the Login page.
AutoPi Wi-Fi/NB and 4G/LTE devices before 2019-10-15 allows an attacker to perform a brute-force attack or dictionary attack to gain access to the WiFi network, which provides root access to the device. The default WiFi password and WiFi SSID are derived from the same hash function output (input is only 8 characters), which allows an attacker to deduce the WiFi password from the WiFi SSID.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password Appstore module (Mendix 7 compatible) (All versions < V3.2.2). Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.
GL-iNet products AR750/AR750S/AR300M/AR300M16/MT300N-V2/B1300/MT1300/SFT1200/X750 v4.3.11, MT3000/MT2500/AXT1800/AX1800/A1300/X300B v4.5.16, XE300 v4.3.16, E750 v4.3.12, AP1300/S1300 v4.3.13, and XE3000/X3000 v4.4 were discovered to contain a remote code execution (RCE) vulnerability.
Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.
The Theme My Login 2FA WordPress plugin before 1.2 does not rate limit 2FA validation attempts, which may allow an attacker to brute-force all possibilities, which shouldn't be too long, as the 2FA codes are 6 digits.
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials.
Dell PowerScale OneFS versions prior to 9.13.0.0 contains an improper restriction of excessive authentication attempts vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
VAXstations running Open VMS 5.3 through 5.5-2 with VMS DECwindows or MOTIF do not properly disable access to user accounts that exceed the break-in limit threshold for failed login attempts, which makes it easier for attackers to conduct brute force password guessing.
Dell RecoverPoint for Virtual Machines 6.0.x contains a vulnerability. An improper Restriction of Excessive Authentication vulnerability where a Network attacker could potentially exploit this vulnerability, leading to a brute force attack or a dictionary attack against the RecoverPoint login form and a complete system compromise. This allows attackers to brute-force the password of valid users in an automated manner.
In ExtremeGuest Essentials before 25.5.0, captive-portal may permit unauthorized access via manual brute-force procedure. Under certain ExtremeGuest Essentials captive-portal SSID configurations, repeated manual login attempts may allow an unauthenticated device to be marked as authenticated and obtain network access. Client360 logs may display the client MAC as the username despite no MAC-authentication being enabled.
Improper Restriction of Excessive Authentication Attempts vulnerability in Drupal Mail Login allows Brute Force.This issue affects Mail Login: from 3.0.0 before 3.2.0, from 4.0.0 before 4.2.0.