Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-44867

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-01 May, 2025 | 00:00
Updated At-01 May, 2025 | 20:24
Rejected At-
Credits

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetNetCheckTools function via the hostName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:01 May, 2025 | 00:00
Updated At:01 May, 2025 | 20:24
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetNetCheckTools function via the hostName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/Summermu/VulnForIoT/tree/main/Tenda_W20E/formSetNetCheckTools/readme.md
N/A
Hyperlink: https://github.com/Summermu/VulnForIoT/tree/main/Tenda_W20E/formSetNetCheckTools/readme.md
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:01 May, 2025 | 18:15
Updated At:27 May, 2025 | 16:31

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetNetCheckTools function via the hostName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>w20e_firmware>>15.11.0.6
cpe:2.3:o:tenda:w20e_firmware:15.11.0.6:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>w20e>>-
cpe:2.3:h:tenda:w20e:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/Summermu/VulnForIoT/tree/main/Tenda_W20E/formSetNetCheckTools/readme.mdcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://github.com/Summermu/VulnForIoT/tree/main/Tenda_W20E/formSetNetCheckTools/readme.md
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

270Records found

CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.23%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.73%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5438
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.53% / 66.40%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:00
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 WPS command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. Affected by this vulnerability is the function WPS of the file /goform/WPS. The manipulation of the argument PIN leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5447
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.46%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5444
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5504
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.26% / 90.54%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formWsc command injection

A vulnerability has been found in TOTOLINK X2000R 1.0.0-B20230726.1108 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWsc. The manipulation of the argument peerRptPin leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5446
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_pingGatewayByBBS os command injection

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5439
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:31
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 verifyFacebookLike os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5515
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.26% / 90.54%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 17:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formMapDel command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X2000R 1.0.0-B20230726.1108. Affected by this issue is some unknown functionality of the file /boafrm/formMapDel. The manipulation of the argument devicemac1 leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5441
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:31
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-4304
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.53% / 66.34%
||
7 Day CHG~0.00%
Published-05 Jan, 2023 | 09:59
Updated-28 May, 2025 | 13:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
eprintsug ulcc-core toolbox command injection

A vulnerability was found in eprintsug ulcc-core. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file cgi/toolbox/toolbox. The manipulation of the argument password leads to command injection. The attack can be launched remotely. The patch is named 811edaae81eb044891594f00062a828f51b22cb1. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-217447.

Action-Not Available
Vendor-ulcc-core_projecteprintsug
Product-ulcc-coreulcc-core
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-20926
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.3||MEDIUM
EPSS-0.13% / 33.07%
||
7 Day CHG~0.00%
Published-10 Nov, 2022 | 17:36
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centerCisco Firepower Management Center
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-4414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.92% / 89.21%
||
7 Day CHG~0.00%
Published-18 Aug, 2023 | 16:00
Updated-21 Nov, 2024 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Byzoro Smart S85F Management Platform decodmail.php command injection

A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230807. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237517 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-byzoroByzoro
Product-smart_s85fSmart S85F Management Platform
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5147
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.47%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 11:31
Updated-29 May, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore NBR1005GPEV2/NBR200V2/B6V2 network_tools tools_ping command injection

A vulnerability was found in Netcore NBR1005GPEV2, NBR200V2 and B6V2 up to 20250508 and classified as critical. This issue affects the function tools_ping of the file /usr/bin/network_tools. The manipulation of the argument url leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-NBR1005GPEV2NBR200V2B6V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4999
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 46.15%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi sub_4153FC command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000 and classified as critical. Affected by this issue is the function sub_4153FC of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument supplicant_rnd_id_en leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5146
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.47%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 07:00
Updated-29 May, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore NBR200V2 HTTP Header routerd passwd_set command injection

A vulnerability has been found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2 and NBR200V2 up to 20250508 and classified as critical. This vulnerability affects the function passwd_set of the file /usr/bin/routerd of the component HTTP Header Handler. The manipulation of the argument pwd leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-NAP930NBR1005GPEV2B6V2COVER5NBR100V2NAP830NBR200V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5145
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.54% / 80.62%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 05:31
Updated-11 Jul, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore POWER13 Query String cgi-bin command injection

A vulnerability, which was classified as critical, was found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2, NBR200V2 and POWER13 up to 20250508. This affects an unknown part of the file /www/cgi-bin/ of the component Query String Handler. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-B6V2NAP930NBR100V2NBR1005GPEV2NBR200V2COVER5NAP830POWER13
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5000
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 46.15%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi control_panel_sw command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000. It has been classified as critical. This affects the function control_panel_sw of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument filename leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4850
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.87% / 85.76%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 03:00
Updated-24 May, 2025 | 00:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection

A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4851
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.92% / 74.99%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 03:31
Updated-24 May, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection

A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4849
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.92% / 74.99%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 02:31
Updated-24 May, 2025 | 00:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4747
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.47%
||
7 Day CHG~0.00%
Published-16 May, 2025 | 05:00
Updated-16 May, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Bohua NetDragon Firewall ip_status.php command injection

A vulnerability was found in Bohua NetDragon Firewall 1.0 and classified as critical. This issue affects some unknown processing of the file /systemstatus/ip_status.php. The manipulation of the argument subnet leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Bohua
Product-NetDragon Firewall
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4729
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.87% / 85.76%
||
7 Day CHG~0.00%
Published-15 May, 2025 | 23:31
Updated-20 Jun, 2025 | 14:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3002R/A3002RU HTTP POST Request formMapDelDevice command injection

A vulnerability was found in TOTOLINK A3002R and A3002RU 3.0.0-B20230809.1615. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a3002rua3002ru_firmwarea3002ra3002r_firmwareA3002RA3002RU
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-40994
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.3||MEDIUM
EPSS-1.52% / 80.51%
||
7 Day CHG~0.00%
Published-15 Oct, 2021 | 14:07
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba ClearPass Policy Manager version(s): ClearPass Policy Manager 6.10.x prior to 6.10.2 - - ClearPass Policy Manager 6.9.x prior to 6.9.7-HF1 - - ClearPass Policy Manager 6.8.x prior to 6.8.9-HF1. Aruba has released patches for ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-40995
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.3||MEDIUM
EPSS-1.52% / 80.51%
||
7 Day CHG~0.00%
Published-15 Oct, 2021 | 14:10
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba ClearPass Policy Manager version(s): ClearPass Policy Manager 6.10.x prior to 6.10.2 - - ClearPass Policy Manager 6.9.x prior to 6.9.7-HF1 - - ClearPass Policy Manager 6.8.x prior to 6.8.9-HF1. Aruba has released patches for ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-43510
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-4.7||MEDIUM
EPSS-0.29% / 51.96%
||
7 Day CHG~0.00%
Published-24 Oct, 2023 | 18:14
Updated-11 Sep, 2024 | 17:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Remote Command Injection in ClearPass Policy Manager Web-Based Management Interface Leading to Partial System Compromise

A vulnerability in the ClearPass Policy Manager web-based management interface allows remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as a non-privileged user on the underlying operating system leading to partial system compromise.

Action-Not Available
Vendor-Aruba NetworksHewlett Packard Enterprise (HPE)
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4453
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.69%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSysCmd command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44835
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-2.93% / 85.89%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-28 May, 2025 | 16:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-816 A2V1.1.0B05 was found to contain a command injection in iptablesWebsFilterRun, which allows remote attackers to execute arbitrary commands via shell.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-816_a2dir-816_a2_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44838
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-15.49% / 94.40%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CPE CP900 V6.3c.1144_B20190715 was discovered to contain a command injection vulnerability in the setUploadUserData function via the FileName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-cp900_firmwarecp900n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.69%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 23:31
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L sub_454F2C command injection

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44847
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.07% / 93.54%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA600-PoE V5.3c.6665_B20180820 was found to contain a command injection vulnerability in the setWebWlanIdx function via the webWlanIdx parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca600-poeca600-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-4120
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-65.55% / 98.43%
||
7 Day CHG~0.00%
Published-03 Aug, 2023 | 09:00
Updated-15 Oct, 2024 | 20:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Byzoro Smart S85F Management Platform importhtml.php command injection

A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230722 and classified as critical. This issue affects some unknown processing of the file importhtml.php. The manipulation of the argument sql leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-235967. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-byzoroByzoro
Product-smart_s85fSmart S85F Management Platform
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44836
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-15.49% / 94.40%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CPE CP900 V6.3c.1144_B20190715 was discovered to contain a command injection vulnerability in the setApRebootScheCfg function via the hour or minute parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-cp900_firmwarecp900n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44861
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-15.49% / 94.40%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-21 May, 2025 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA300-POE V6.2c.884_B20180522 was found to contain a command injection vulnerability in the CloudSrvUserdataVersionCheck function via the url parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca300-poeca300-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.69%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L wake_on_lan command injection

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-36457
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.3||MEDIUM
EPSS-2.63% / 85.13%
||
7 Day CHG~0.00%
Published-05 Jul, 2023 | 20:57
Updated-18 Oct, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
1Panel vulnerable to command injection when adding container repositories

1Panel is an open source Linux server operation and maintenance management panel. Prior to version 1.3.6, an authenticated attacker can craft a malicious payload to achieve command injection when adding container repositories. The vulnerability has been fixed in v1.3.6.

Action-Not Available
Vendor-FIT2CLOUD Inc.1Panel (FIT2CLOUD Inc.)
Product-1panel1Panel1panel
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-36458
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.3||MEDIUM
EPSS-2.63% / 85.13%
||
7 Day CHG~0.00%
Published-05 Jul, 2023 | 20:57
Updated-18 Oct, 2024 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
1Panel vulnerable to ommand injection when entering the container terminal

1Panel is an open source Linux server operation and maintenance management panel. Prior to version 1.3.6, an authenticated attacker can craft a malicious payloads to achieve command injection when entering the container terminal. The vulnerability has been fixed in v1.3.6.

Action-Not Available
Vendor-FIT2CLOUD Inc.1Panel (FIT2CLOUD Inc.)
Product-1panel1Panel1panel
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44862
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-15.49% / 94.40%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-21 May, 2025 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA300-POE V6.2c.884_B20180522 was found to contain a command injection vulnerability in the recvUpgradeNewFw function via the fwUrl parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca300-poeca300-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4454
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.69%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L wake_on_lan command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been declared as critical. This vulnerability affects the function wake_on_lan. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44846
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-15.49% / 94.40%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA600-PoE V5.3c.6665_B20180820 was found to contain a command injection vulnerability in the recvUpgradeNewFw function via the fwUrl parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca600-poeca600-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44854
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-15.49% / 94.40%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CP900 V6.3c.1144_B20190715 was found to contain a command injection vulnerability in the setUpgradeUboot function via the FileName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-cp900_firmwarecp900n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4076
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.38% / 79.50%
||
7 Day CHG-0.16%
Published-29 Apr, 2025 | 18:00
Updated-02 May, 2025 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-AC3600 Password lighttpd.cgi easy_uci_set_option_string_0 command injection

A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-LB-LINK
Product-BL-AC3600
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-3987
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.50% / 84.72%
||
7 Day CHG+0.31%
Published-27 Apr, 2025 | 21:31
Updated-07 May, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N150RT formWsc command injection

A vulnerability was found in TOTOLINK N150RT 3.4.0-B20190525. It has been rated as critical. This issue affects some unknown processing of the file /boafrm/formWsc. The manipulation of the argument localPin leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n150rt_firmwaren150rtN150RT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4135
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.16% / 77.71%
||
7 Day CHG~0.00%
Published-30 Apr, 2025 | 17:31
Updated-23 Jun, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear WG302v2 ui_get_input_value command injection

A vulnerability was found in Netgear WG302v2 up to 5.2.9 and classified as critical. Affected by this issue is the function ui_get_input_value. The manipulation of the argument host leads to command injection. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-wg302v2wg302v2_firmwareWG302v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 56.84%
||
7 Day CHG~0.00%
Published-30 Apr, 2025 | 14:00
Updated-13 May, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear JWNR2000v2 cmd_wireless command injection

A vulnerability was found in Netgear JWNR2000v2 1.0.0.11. It has been declared as critical. Affected by this vulnerability is the function cmd_wireless. The manipulation of the argument host leads to command injection. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-jwnr2000v2_firmwarejwnr2000v2JWNR2000v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4122
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.34% / 56.03%
||
7 Day CHG~0.00%
Published-30 Apr, 2025 | 14:31
Updated-12 May, 2025 | 19:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear JWNR2000v2 sub_435E04 command injection

A vulnerability was found in Netgear JWNR2000v2 1.0.0.11. It has been rated as critical. Affected by this issue is the function sub_435E04. The manipulation of the argument host leads to command injection. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-jwnr2000v2_firmwarejwnr2000v2JWNR2000v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2647
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.35% / 84.28%
||
7 Day CHG~0.00%
Published-11 May, 2023 | 07:31
Updated-02 Aug, 2024 | 06:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Weaver E-Office File Upload utility_all.php command injection

A vulnerability was found in Weaver E-Office 9.5 and classified as critical. Affected by this issue is some unknown functionality of the file /webroot/inc/utility_all.php of the component File Upload Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-228776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-weaverWeaver
Product-e-officeE-Office
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4340
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 29.81%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • Next
Details not found