IBM Sterling B2B Integrator Standard Edition 5.2.0.0 through 5.2.6.5 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially-crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 167878.
IBM Jazz for Service Management 1.1.3, 1.1.3.1, and 1.1.3.2 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially-crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 159122.
alltube is an html front end for youtube-dl. On releases prior to 3.0.3, an attacker could craft a special HTML page to trigger either an open redirect attack or a Server-Side Request Forgery attack (depending on how AllTube is configured). The impact is mitigated by the fact the SSRF attack is only possible when the `stream` option is enabled in the configuration. (This option is disabled by default.) 3.0.3 contains a fix for this vulnerability.
Setor Informatica S.I.L version 3.0 is vulnerable to Open Redirect via the hprinter parameter, allows remote attackers to execute arbitrary code.
IBM StoredIQ 7.6 could allow a remote attacker to conduct phishing attacks, using an open redirect attack. By persuading a victim to visit a specially-crafted Web site, a remote attacker could exploit this vulnerability to spoof the URL displayed to redirect a user to a malicious Web site that would appear to be trusted. This could allow the attacker to obtain highly sensitive information or conduct further attacks against the victim. IBM X-Force ID: 158699.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.
In affected Octopus Server versions when the server HTTP and HTTPS bindings are configured to localhost, Octopus Server will allow open redirects.
XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. In affected versions there is no protection against URL redirection to untrusted sites, in particular some well known parameters (xredirect) can be used to perform url redirections. This problem has been patched in XWiki 12.10.7 and XWiki 13.3RC1. Users are advised to update. There are no known workarounds for this issue.
Sysaid – sysaid Open Redirect - An Attacker can change the redirect link at the parameter "redirectURL" from"GET" request from the url location: /CommunitySSORedirect.jsp?redirectURL=https://google.com. Unvalidated redirects and forwards are possible when a web application accepts untrusted input that could cause the web application to redirect the request to a URL contained within untrusted input. By modifying untrusted URL input to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
An open redirect issue was discovered in Kibana that could lead to a user being redirected to an arbitrary website if they use a maliciously crafted Kibana URL.
E-Series SANtricity OS Controller Software 11.x versions through 11.70.2 are vulnerable to host header injection attacks that could allow an attacker to redirect users to malicious websites.
Open Redirect in GitHub repository microweber/microweber prior to 1.2.19.
Adenza AxiomSL ControllerView through 10.8.1 allows redirection for SSO login URLs.
Shopware is an open source e-commerce software platform. An open redirect vulnerability has been discovered. Users may be arbitrary redirected due to incomplete URL handling in the shopware router. This issue has been resolved in version 5.7.7. There is no workaround and users are advised to upgrade as soon as possible.
A flaw was found in the Keycloak Node.js Adapter. This flaw allows an attacker to benefit from an Open Redirect vulnerability in the checkSso function.
An open redirect vulnerability in GitLab EE/CE affecting all versions from 11.1 prior to 14.10.5, 15.0 prior to 15.0.4, and 15.1 prior to 15.1.1, allows an attacker to redirect users to an arbitrary location if they trust the URL.
There is an unvalidated redirect vulnerability in Esri Portal for ArcGIS 11.0 and below that may allow a remote, unauthenticated attacker to craft a URL that could redirect a victim to an arbitrary website, simplifying phishing attacks.
Open redirect vulnerability in the password reset functionality in POSH 3.0 through 3.2.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in the redirect parameter to portal/scr_sendmd5.php.
A vulnerability in Cisco Webex Meetings and Cisco Webex Meetings Server could allow an unauthenticated, remote attacker to redirect users to a malicious file. This vulnerability is due to improper validation of URL paths in the application interface. An attacker could exploit this vulnerability by persuading a user to follow a specially crafted URL that is designed to cause Cisco Webex Meetings to include a remote file in the web UI. A successful exploit could allow the attacker to cause the application to offer a remote file to a user, which could allow the attacker to conduct further phishing or spoofing attacks.
Open Redirect in GitHub repository mosparo/mosparo prior to 1.0.2.
Tableau Server fails to validate certain URLs that are embedded in emails sent to Tableau Server users.
Open redirect vulnerability in the Countries Management’s edit region page in Liferay Portal 7.4.3.45 through 7.4.3.101, and Liferay DXP 2023.Q3 before patch 6, and 7.4 update 45 through 92 allows remote attackers to redirect users to arbitrary external URLs via the _com_liferay_address_web_internal_portlet_CountriesManagementAdminPortlet_redirect parameter.
This affects all versions of package Flask-Security. When using the get_post_logout_redirect and get_post_login_redirect functions, it is possible to bypass URL validation and redirect a user to an arbitrary URL by providing multiple back slashes such as \\\evil.com/path. This vulnerability is only exploitable if an alternative WSGI server other than Werkzeug is used, or the default behaviour of Werkzeug is modified using 'autocorrect_location_header=False. **Note:** Flask-Security is not maintained anymore.
A flaw was found in mod_auth_openidc before version 2.4.1. An open redirect issue exists in URLs with a slash and backslash at the beginning.
An Open Redirect vulnerability was found in osTicky2 below 2.2.8. osTicky (osTicket Bridge) by SmartCalc is a Joomla 3.x extension that provides Joomla fronted integration with osTicket, a popular Support ticket system. The Open Redirect vulnerability allows attackers to control the return parameter in the URL to a base64 malicious URL.
Calendarinho is an open source calendaring application to manage large teams of consultants. An Open Redirect issue occurs when a web application redirects users to external URLs without proper validation. This can lead to phishing attacks, where users are tricked into visiting malicious sites, potentially leading to information theft and reputational damage to the website used for redirection. The problem is has been patched in commit `15b2393`. Users are advised to update to a commit after `15b2393`. There are no known workarounds for this vulnerability.
The login.jsp resource in Jira before version 8.5.2, and from version 8.6.0 before version 8.6.1 allows remote attackers to redirect users to a different website which they may use as part of performing a phishing attack via an open redirect in the os_destination parameter.
HCL DRYiCE MyXalytics is impacted by an Open Redirect vulnerability which could allow an attacker to redirect users to malicious sites, potentially leading to phishing attacks or other security threats.
Zentao versions 4.1.3 and before has a URL redirect vulnerability, which prevents the system from functioning properly.
Vulnerability in the PeopleSoft Enterprise PeopleTools product of Oracle PeopleSoft (component: Workflow). Supported versions that are affected are 8.59, 8.60 and 8.61. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise PeopleSoft Enterprise PeopleTools. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in PeopleSoft Enterprise PeopleTools, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of PeopleSoft Enterprise PeopleTools accessible data as well as unauthorized read access to a subset of PeopleSoft Enterprise PeopleTools accessible data. CVSS 3.1 Base Score 6.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).
An attacker could construct a URL within the application that causes a redirection to an arbitrary external domain and could be leveraged to facilitate phishing attacks against application users.
Potential open redirect vulnerability in opentext Service Management Automation X (SMAX) versions 2020.05, 2020.08, 2020.11, 2021.02, 2021.05, 2021.08, 2021.11, 2022.05, 2022.11 and opentext Asset Management X (AMX) versions 2021.08, 2021.11, 2022.05, 2022.11. The vulnerability could allow attackers to redirect a user to malicious websites.
In JetBrains TeamCity before 2025.03.2 open redirect was possible on editing VCS Root page
The OAuth implementation in workers-oauth-provider that is part of MCP framework https://github.com/cloudflare/workers-mcp , did not correctly validate that redirect_uri was on the allowed list of redirect URIs for the given client registration. Fixed in: https://github.com/cloudflare/workers-oauth-provider/pull/26 https://github.com/cloudflare/workers-oauth-provider/pull/26 Impact: Under certain circumstances (see below), if a victim had previously authorized with a server built on workers-oath-provider, and an attacker could later trick the victim into visiting a malicious web site, then attacker could potentially steal the victim's credentials to the same OAuth server and subsequently impersonate them. In order for the attack to be possible, the OAuth server's authorized callback must be designed to auto-approve authorizations that appear to come from an OAuth client that the victim has authorized previously. The authorization flow is not implemented by workers-oauth-provider; it is up to the application built on top to decide whether to implement such automatic re-authorization. However, many applications do implement such logic. Note: It is a basic, well-known requirement that OAuth servers should verify that the redirect URI is among the allowed list for the client, both during the authorization flow and subsequently when exchanging the authorization code for an access token. workers-oauth-provider implemented only the latter check, not the former. Unfortunately, the former is the much more important check. Readers who are familiar with OAuth may recognize that failing to check redirect URIs against the allowed list is a well-known, basic mistake, covered extensively in the RFC and elsewhere. The author of this library would like everyone to know that he was, in fact, well-aware of this requirement, thought about it a lot while designing the library, and then, somehow, forgot to actually make sure the check was in the code. That is, it's not that he didn't know what he was doing, it's that he knew what he was doing but flubbed it.
Open redirect vulnerability in PowerCMS (6 Series, 5 Series, and 4 Series) allows a remote unauthenticated attacker to redirect users to arbitrary web sites via a specially crafted URL. Note that all versions of PowerCMS 3 Series and earlier which are unsupported (End-of-Life, EOL) are also affected by this vulnerability.
Franklin Fueling Systems System Sentinel AnyWare (SSA) version 1.6.24.492 is vulnerable to Open Redirect. The 'path' parameter of the prefs.asp resource allows an attacker to redirect a victim user to an arbitrary web site using a crafted URL.
An attacker could have performed HTML template injection via Reader Mode and exfiltrated user information. This vulnerability affects Firefox for iOS < 120.
An issue was discovered in ownCloud owncloud/oauth2 before 0.6.1, when Allow Subdomains is enabled. An attacker is able to pass in a crafted redirect-url that bypasses validation, and consequently allows an attacker to redirect callbacks to a Top Level Domain controlled by the attacker.
kkFileView v4.3.0 is vulnerable to Incorrect Access Control.
Websites directing users to long URLs that caused eliding to occur in the location view could leverage the truncating behavior to potentially trick users into thinking they were on a different webpage This vulnerability affects Focus < 138.
The Advanced Advertising System plugin for WordPress is vulnerable to Open Redirect in all versions up to, and including, 1.3.1. This is due to insufficient validation on the redirect url supplied via the 'redir' parameter. This makes it possible for unauthenticated attackers to redirect users to potentially malicious sites if they can successfully trick them into performing an action.
In Ktor through 1.2.6, the client resends data from the HTTP Authorization header to a redirect location.
URL Redirection to Untrusted Site ('Open Redirect') vulnerability in PluginOps Landing Page Builder – Lead Page – Optin Page – Squeeze Page – WordPress Landing Pages.This issue affects Landing Page Builder – Lead Page – Optin Page – Squeeze Page – WordPress Landing Pages: from n/a through 1.5.1.5.
A vulnerability in the web interface of Lenovo EZ Media & Backup Center, ix2 & ix2-dl version 4.1.406.34763 and prior could allow an unauthenticated, remote attacker to redirect a user to an untrusted web page.
Secure Entry Server before 4.7.0 contains a URI Redirection vulnerability which could allow remote attackers to conduct phishing attacks due to HSP_AbsoluteRedirects being disabled by default.
Open redirect via parameter ‘p’ in login.php in Centreon (19.04.4 and below) allows an attacker to craft a payload and execute unintended behavior.
An open redirect through HTML injection in user messages in Asp.Net Zero before 12.3.0 allows remote attackers to redirect targeted victims to any URL via the '<meta http-equiv="refresh"' in the WebSocket messages.
A vulnerability in the web-based management interface of Cisco Crosswork Network Services Orchestrator (NSO) could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. This vulnerability is due to improper input validation of a parameter in an HTTP request. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to redirect a user to a malicious website.
A vulnerability, which was classified as critical, has been found in Freshdesk Plugin 1.7 on WordPress. Affected by this issue is some unknown functionality. The manipulation leads to open redirect. The attack may be launched remotely. Upgrading to version 1.8 is able to address this issue. The patch is identified as 2aaecd4e0c7c6c1dc4e6a593163d5f7aa0fa5d5b. It is recommended to upgrade the affected component. VDB-226118 is the identifier assigned to this vulnerability.
A vulnerability, which was classified as problematic, has been found in WooSidebars Plugin up to 1.4.1 on WordPress. Affected by this issue is the function enable_custom_post_sidebars of the file classes/class-woo-sidebars.php. The manipulation of the argument sendback leads to open redirect. The attack may be launched remotely. Upgrading to version 1.4.2 is able to address this issue. The patch is identified as 1ac6d6ac26e185673f95fc1ccc56a392169ba601. It is recommended to upgrade the affected component. VDB-230654 is the identifier assigned to this vulnerability.