CVE-2026-0517 is a denial-of-service vulnerability in versions of Secure Access Server prior to 14.20. An attacker can send a specially crafted packet to a server and cause the server to crash
There is a memory management vulnerability in Absolute Secure Access server versions 9.0 to 13.54. Attackers with network access to the server can cause a Denial of Service by sending a specially crafted sequence of packets to the server. The attack complexity is low, there are no attack requirements, privileges, or user interaction required. Loss of availability is high; there is no impact on confidentiality or integrity.
There is an insufficient input validation vulnerability in the Warehouse component of Absolute Secure Access prior to 13.06. Attackers with system administrator permissions can impair the availability of certain elements of the Secure Access administrative UI by writing invalid data to the warehouse over the network. There is no loss of warehouse integrity or confidentiality, the security scope is unchanged. Loss of availability is high.
CVE-2025-59596 is a denial-of-service vulnerability in Secure Access Windows client versions 12.0 to 14.10 that is addressed in version 14.12. If a local networking policy is active, attackers on an adjacent network may be able to send a crafted packet and cause the client system to crash.
Cryptocat before 2.0.22 has Remote Denial of Service via username
Dell BSAFE Micro Edition Suite, versions prior to 4.5.1, contain a Buffer Over-Read Vulnerability.
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
An issue was discovered in Fort before 1.6.3. A malicious RPKI repository that descends from a (trusted) Trust Anchor can serve (via rsync or RRDP) a signed object containing an empty signedAttributes field. Fort accesses the set's elements without sanitizing it first. Because Fort is an RPKI Relying Party, a crash can lead to Route Origin Validation unavailability, which can lead to compromised routing.
python before versions 2.7.15, 3.4.9, 3.5.6rc1, 3.6.5rc1 and 3.7.0 is vulnerable to catastrophic backtracking in pop3lib's apop() method. An attacker could use this flaw to cause denial of service.
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a denial of service condition of the core functionality of the CPU, compromising the availability of the system.
In modem EMM, there is a possible system crash due to improper input validation. This could lead to remote denial of service with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01183647; Issue ID: MOLY01183647 (MSV-963).
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
A vulnerability has been found in Dahua products. Attackers can send carefully crafted data packets to the interface with vulnerabilities, causing the device to crash.
A flaw was found in Undertow. Servlets using a method that calls HttpServletRequestImpl.getParameterNames() can cause an OutOfMemoryError when the client sends a request with large parameter names. This issue can be exploited by an unauthorized user to cause a remote denial-of-service (DoS) attack.
A vulnerability has been found in Dahua products. Attackers can send carefully crafted data packets to the interface with vulnerabilities, causing the device to crash.
A prototype pollution attack in cached-path-relative versions <=1.0.1 allows an attacker to inject properties on Object.prototype which are then inherited by all the JS objects through the prototype chain causing a DoS attack.
A vulnerability has been found in Dahua products.Attackers can send carefully crafted data packets to the interface with vulnerabilities, causing the device to crash.
A flaw was found in knot-resolver before version 2.3.0. Malformed DNS messages may cause denial of service.
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition.
.NET and Visual Studio Denial of Service Vulnerability
dd-trace-cpp is the Datadog distributed tracing for C++. When the library fails to extract trace context due to malformed unicode, it logs the list of audited headers and their values using the `nlohmann` JSON library. However, due to the way the JSON library is invoked, it throws an uncaught exception, which results in a crash. This vulnerability has been patched in version 0.2.2.
Windows Standards-Based Storage Management Service Denial of Service Vulnerability
An issue was discovered in the America's Army Proving Grounds platform for the Unreal Engine. With a false packet sent via UDP, the application server responds with several bytes, giving the possibility of DoS amplification, even being able to be used in DDoS attacks.
A flaw was found in Undertow that can cause remote denial of service attacks. When the server uses the FormEncodedDataDefinition.doParse(StreamSourceChannel) method to parse large form data encoding with application/x-www-form-urlencoded, the method will cause an OutOfMemory issue. This flaw allows unauthorized users to cause a remote denial of service (DoS) attack.
MediaWiki before 1.19.4 and 1.20.x before 1.20.3 allows remote attackers to cause a denial of service (application crash) by sending a specially crafted request.
An issue was discovered on LG mobile devices with Android OS 7.2, 8.0, 8.1, 9, and 10 software. An application crash can occur because of incorrect application-level input validation. The LG ID is LVE-SMP-200018 (July 2020).
Improper input validation in CVC5 Solver v1.1.3 allows attackers to cause a Denial of Service (DoS) via a crafted SMT2 input file.
Improper input validation in OneFlow-Inc. Oneflow v0.9.1 allows attackers to cause a Denial of Service (DoS) via inputting a negative value into the dim parameter.
Improper input validation in OneFlow-Inc. Oneflow v0.9.1 allows attackers to cause a Denial of Service (DoS) via inputting a negative value into the oneflow.full parameter.
An issue in OneFlow-Inc. Oneflow v0.9.1 allows attackers to cause a Denial of Service (DoS) when index as a negative number exceeds the range of size.
MileSight DeviceHub -Â CWE-20 Improper Input Validation may allow Denial of Service
An issue in OneFlow-Inc. Oneflow v0.9.1 allows attackers to cause a Denial of Service (DoS) via inputting a negative value into the oneflow.index_select parameter.
An issue in the oneflow.scatter_nd parameter OneFlow-Inc. Oneflow v0.9.1 allows attackers to cause a Denial of Service (DoS) when index parameter exceeds the range of shape.
A flaw was found in 389-ds-base. A specially-crafted LDAP query can potentially cause a failure on the directory server, leading to a denial of service
The affected product does not properly validate input, which may allow an attacker to execute a denial-of-service attack on the NIO 50 (all versions).
Input verification vulnerability in the storage module. Successful exploitation of this vulnerability may cause the device to restart.
Dovecot before 2.3.13 has Improper Input Validation in lda, lmtp, and imap, leading to an application crash via a crafted email message with certain choices for ten thousand MIME parts.
sflow decode package does not employ sufficient packet sanitisation which can lead to a denial of service attack. Attackers can craft malformed packets causing the process to consume large amounts of memory resulting in a denial of service.
A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices.
Discourse is an open-source discussion platform. Prior to version 3.2.3 on the `stable` branch and version 3.3.0.beta3 on the `tests-passed` branch, Oneboxing against a carefully crafted malicious URL can reduce the availability of a Discourse instance. The problem has been patched in version 3.2.3 on the `stable` branch and version 3.3.0.beta3 on the `tests-passed` branch. There are no known workarounds available for this vulnerability.
All versions of package lite-server are vulnerable to Denial of Service (DoS) when an attacker sends an HTTP request and includes control characters that the decodeURI() function is unable to parse.
A vulnerability in the Smart Install feature of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to trigger a reload of an affected device, resulting in a denial of service (DoS) condition, or to execute arbitrary code on an affected device. The vulnerability is due to improper validation of packet data. An attacker could exploit this vulnerability by sending a crafted Smart Install message to an affected device on TCP port 4786. A successful exploit could allow the attacker to cause a buffer overflow on the affected device, which could have the following impacts: Triggering a reload of the device, Allowing the attacker to execute arbitrary code on the device, Causing an indefinite loop on the affected device that triggers a watchdog crash. Cisco Bug IDs: CSCvg76186.
The package muhammara before 2.6.0; all versions of package hummus are vulnerable to Denial of Service (DoS) when PDFStreamForResponse() is used with invalid data.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.
Insufficient validation of the IOCTL input buffer in AMD μProf may allow an attacker to send an arbitrary buffer leading to a potential Windows kernel crash resulting in denial of service.
Permission verification vulnerability in the system sharing pop-up module Impact: Successful exploitation of this vulnerability will affect availability.
Transient DOS while processing DL NAS Transport message when message ID is not defined in the 3GPP specification.
A vulnerability in the Control and Provisioning of Wireless Access Points (CAPWAP) protocol component of Cisco Wireless LAN Controller (WLC) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability is due to improper input validation on fields within CAPWAP Discovery Request packets by the affected device. An attacker could exploit this vulnerability by sending malicious CAPWAP Discovery Request packets to the Cisco WLC Software. A successful exploit could allow the attacker to cause the Cisco WLC Software to disconnect associated access points (APs). While the APs disconnect and reconnect, service will be unavailable for a brief period of time, resulting in a DoS condition.
A vulnerability in the XCP Router service of the Cisco Unified Communications Manager IM & Presence Service (CUCM IM&P) and the Cisco TelePresence Video Communication Server (VCS) and Expressway could allow an unauthenticated, remote attacker to cause a temporary service outage for all IM&P users, resulting in a denial of service (DoS) condition. The vulnerability is due to improper validation of user-supplied input. An attacker could exploit this vulnerability by sending a malicious IPv4 or IPv6 packet to an affected device on TCP port 7400. An exploit could allow the attacker to overread a buffer, resulting in a crash and restart of the XCP Router service. Cisco Bug IDs: CSCvg97663, CSCvi55947.
Improper validation of certain metadata input may result in the server not correctly serialising BSON. This can be performed pre-authentication and may cause unexpected application behavior including unavailability of serverStatus responses. This issue affects MongoDB Server v7.0 versions prior to 7.0.6, MongoDB Server v6.0 versions prior to 6.0.14 and MongoDB Server v.5.0 versions prior to 5.0.25.