An issue in Daily Habit Tracker v.1.0 allows a remote attacker to manipulate trackers via the home.php, add-tracker.php, delete-tracker.php, update-tracker.php components.
A vulnerability was determined in 1000projects Online Student Project Report Submission and Evaluation System 1.0. The affected element is an unknown function of the file /admin/controller/faculty_controller.php. This manipulation of the argument new_image causes unrestricted upload. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
A vulnerability, which was classified as critical, has been found in CampCodes Computer Laboratory Management System 1.0. Affected by this issue is some unknown functionality of the file /class/edit/edit. The manipulation of the argument e_photo leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.
A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
The Web interface of Evolution Controller Versions 2.04.560.31.03.2024 and below contains poorly configured access control, allowing for an unauthenticated attacker to update and add user profiles within the application, and gain full access of the site.
A vulnerability, which was classified as critical, has been found in Anhui Deshun Intelligent Technology Jieshun JieLink+ JSOTC2016 up to 20240805. This issue affects some unknown processing of the file /report/ParkChargeRecord/GetDataList. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
When configuring a stateless firewall filter in Junos OS, terms named using the format "internal-n" (e.g. "internal-1", "internal-2", etc.) are silently ignored. No warning is issued during configuration, and the config is committed without error, but the filter criteria will match all packets leading to unexpected results. Affected releases are Juniper Networks Junos OS: All versions prior to and including 12.3; 14.1X53 versions prior to 14.1X53-D130, 14.1X53-D49; 15.1 versions prior to 15.1F6-S12, 15.1R7-S4; 15.1X49 versions prior to 15.1X49-D161, 15.1X49-D170; 15.1X53 versions prior to 15.1X53-D236, 15.1X53-D496, 15.1X53-D69; 16.1 versions prior to 16.1R7-S4, 16.1R7-S5; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R1-S8, 17.2R3-S1; 17.3 versions prior to 17.3R3-S4; 17.4 versions prior to 17.4R1-S7, 17.4R2-S3; 18.1 versions prior to 18.1R2-S4, 18.1R3-S4; 18.2 versions prior to 18.2R1-S5, 18.2R2-S1; 18.2X75 versions prior to 18.2X75-D40; 18.3 versions prior to 18.3R1-S3; 18.4 versions prior to 18.4R1-S1, 18.4R1-S2.
An issue in Advanced Plugins ultimateimagetool module for PrestaShop before v.2.2.01, allows a remote attacker to escalate privileges and obtain sensitive information via Improper Access Control.
A vulnerability has been found in Anhui Deshun Intelligent Technology Jieshun JieLink+ JSOTC2016 up to 20240805 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /report/ParkOutRecord/GetDataList. The manipulation leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
The issue was addressed with improved memory handling. This issue is fixed in iOS 17.5 and iPadOS 17.5, macOS Sonoma 14.5. An app may be able to disclose kernel memory.
WeGIA < 3.2.0 is vulnerable to Incorrect Access Control in controle/control.php. The application does not validate the value of the old password, so it is possible to change the password by placing any value in the senha_antiga field.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
A vulnerability has been found in ProjectsAndPrograms School Management System up to 6b6fae5426044f89c08d0dd101c7fa71f9042a59. Affected by this issue is some unknown functionality of the file /assets/uploadSllyabus.php. Such manipulation of the argument File leads to unrestricted upload. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable.
Erxes <1.6.1 is vulnerable to Incorrect Access Control. An attacker can bypass authentication by providing a "User" HTTP header that contains any user, allowing them to talk to any GraphQL endpoint.
A vulnerability, which was classified as problematic, was found in Anhui Deshun Intelligent Technology Jieshun JieLink+ JSOTC2016 up to 20240805. Affected is an unknown function of the file /Report/ParkCommon/GetParkInThroughDeivces. The manipulation leads to improper access controls. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
An authentication bypass by assumed-immutable data vulnerability [CWE-302] in the FortiOS SSH login component 7.2.0, 7.0.0 through 7.0.7, 6.4.0 through 6.4.9, 6.2 all versions, 6.0 all versions and FortiProxy SSH login component 7.0.0 through 7.0.5, 2.0.0 through 2.0.10, 1.2.0 all versions may allow a remote and unauthenticated attacker to login into the device via sending specially crafted Access-Challenge response from the Radius server.
jupyter-lsp is a coding assistance tool for JupyterLab (code navigation + hover suggestions + linters + autocompletion + rename) using Language Server Protocol. Installations of jupyter-lsp running in environments without configured file system access control (on the operating system level), and with jupyter-server instances exposed to non-trusted network are vulnerable to unauthorised access and modification of file system beyond the jupyter root directory. This issue has been patched in version 2.2.2 and all users are advised to upgrade. Users unable to upgrade should uninstall jupyter-lsp.
Improper Access Control in GitHub repository ikus060/rdiffweb prior to 2.5.5.
Devices ekorCCP and ekorRCI are vulnerable due to access to the FTP service using default credentials. Exploitation of this vulnerability can allow an attacker to modify critical files that could allow the creation of new users, delete or modify existing users, modify configuration files, install rootkits or backdoors.
Siklu TG Terragraph devices before approximately 2.1.1 have a hardcoded root password that has been revealed via a brute force attack on an MD5 hash. It can be used for "debug login" by an admin. NOTE: the vulnerability is not fixed by the 2.1.1 firmware; instead, it is fixed in newer hardware, which would typically be used with firmware 2.1.1 or later.
In Ampere AltraMax and Ampere Altra before 2.10c, improper access controls allows the OS to reinitialize a disabled root complex.
https://www.hillstonenet.com.cn/ Hillstone Firewall SG-6000 <= 5.0.4.0 is vulnerable to Incorrect Access Control. There is a permission bypass vulnerability in the Hillstone WEB application firewall. An attacker can enter the background of the firewall with super administrator privileges through a configuration error in report.m.
Institute-of-Current-Students 1.0 is vulnerable to Incorrect Access Control in the mydetailsstudent.php endpoint. The myds GET parameter accepts an email address as input and directly returns the corresponding student's personal information without validating the identity or permissions of the requesting user. This allows any authenticated or unauthenticated attacker to enumerate and retrieve sensitive student details by altering the email value in the request URL, leading to information disclosure.
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. The debug port accessible via TCP (a qconn service) lacks access control.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
A vulnerability classified as critical was found in SourceCodester Book Store Management System 1.0. This vulnerability affects unknown code of the file /bsms_ci/index.php. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214588.
Block BYPASS vulnerability in iQ Block Country plugin <= 1.2.18 on WordPress.
A DNS misconfiguration was found in Zyxel NBG7510 firmware versions prior to V1.00(ABZY.3)C0, which could allow an unauthenticated attacker to access the DNS server when the device is switched to the AP mode.
An issue was discovered in RWS WorldServer before 11.7.3. Regular users can create users with the Administrator role via UserWSUserManager.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution.
VMware Workspace ONE Assist prior to 22.10 contains a Broken Access Control vulnerability. A malicious actor with network access to Workspace ONE Assist may be able to obtain administrative access without the need to authenticate to the application.
The web server of some Hikvision wireless bridge products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices.
A vulnerability has been found in LoveCards LoveCardsV2 up to 2.3.2 and classified as critical. This vulnerability affects unknown code of the file /api/system/other of the component Setting Handler. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in zj1983 zz up to 2024-8. This affects an unknown part of the file /resolve. The manipulation of the argument file leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in cld378632668 JavaMall up to 994f1e2b019378ec9444cdf3fce2d5b5f72d28f0. This impacts the function Upload of the file src/main/java/com/macro/mall/controller/MinioController.java. The manipulation results in unrestricted upload. It is possible to launch the attack remotely. This product takes the approach of rolling releases to provide continious delivery. Therefore, version details for affected and updated releases are not available. The vendor was contacted early about this disclosure but did not respond in any way.
An issue in RUoYi v.4.8.0 allows a remote attacker to escalate privileges via the jobId parameter
There is an access control vulnerability in some ZTE PON OLT products. Due to improper access control settings, remote attackers could use the vulnerability to log in to the device and execute any operation.