A vulnerability classified as critical has been found in Go-Tribe gotribe up to cd3ccd32cd77852c9ea73f986eaf8c301cfb6310. Affected is the function Sign of the file pkg/token/token.go. The manipulation of the argument config.key leads to hard-coded credentials. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The patch is identified as 4fb9b9e80a2beedd09d9fde4b9cf5bd510baf18f. It is recommended to apply a patch to fix this issue.
Use of hard-coded MSSQL credentials in PerkinElmer ProcessPlus on Windows allows an attacker to login remove on all prone installations.This issue affects ProcessPlus: through 1.11.6507.0.
Password reset tokens are generated using an insecure source of randomness. Attackers who know the username of the Journyx installation user can bruteforce the password reset and change the administrator password.
ENENSYS IPGuard v2 2.10.0 was discovered to contain hardcoded credentials.
The default credentials for the setup HSQL database (HSQLDB) for FileCatalyst Workflow are published in a vendor knowledgebase article. Misuse of these credentials could lead to a compromise of confidentiality, integrity, or availability of the software. The HSQLDB is only included to facilitate installation, has been deprecated, and is not intended for production use per vendor guides. However, users who have not configured FileCatalyst Workflow to use an alternative database per recommendations are vulnerable to attack from any source that can reach the HSQLDB.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
IBM Security Guardium 11.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174732.
IBM Data Risk Manager 2.0.1, 2.0.2, 2.0.3, 2.0.4, 2.0.5, and 2.0.6 contains a default password for an IDRM administrative account. A remote attacker could exploit this vulnerability to login and execute arbitrary code on the system with root privileges. IBM X-Force ID: 180534.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174975.
IBM SiteProtector Appliance 3.1.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174142.
Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 175066.
IBM Security Verify Access 10.7 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 181395.
Missing Authentication, Files or Directories Accessible to External Parties, Use of Hard-coded Credentials vulnerability in Talya Informatics Elektraweb allows Authentication Bypass. This issue affects Elektraweb: before v17.0.68.
AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system.
Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before.
Zohocorp ManageEngine DDI Central versions 4001 and prior were vulnerable to agent takeover vulnerability due to the hard-coded sensitive keys.
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
Online Course Registration v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
In TinyCheck before commits 9fd360d and ea53de8, the installation script of the tool contained hard-coded credentials to the backend part of the tool. This information could be used by an attacker for unauthorized access to remote data.
Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability in the REST API of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. The vulnerability exists because different installations share a static encryption key. An attacker could exploit this vulnerability by using the static key to craft a valid session token. A successful exploit could allow the attacker to perform arbitrary actions through the REST API with administrative privileges.
The Web Administrative Interface in Mobile Viewpoint Wireless Multiplex Terminal (WMT) Playout Server 20.2.8 and earlier has a default account with a password of "pokon."
Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device.
Weak JWT Secret vulnerabilitiy in EasyVirt DCScope <= 8.6.0 and CO2Scope <= 1.3.0 allows remote attackers to generate JWT for privilege escalation. The HMAC secret used for generating tokens is hardcoded as "somerandomaccesstoken". A weak HMAC secret poses a risk because attackers can use the predictable secret to create valid JSON Web Tokens (JWTs), allowing them access to important information and actions within the application.
A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges.
LB-LINK BL-WR 1300H v.1.0.4 contains hardcoded credentials stored in /etc/shadow which are easily guessable.
A vulnerability in the Telnet service of Cisco Small Business RV110W Wireless-N VPN Firewall Routers could allow an unauthenticated, remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to gain full control of an affected device.
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
Barco wePresent WiPG-1600W firmware includes a hardcoded API account and password that is discoverable by inspecting the firmware image. A malicious actor could use this password to access authenticated, administrative functions in the API. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).
INPRAX "iZZi connect" application on Android contains hard-coded MQTT queue credentials. The same MQTT queue is used by corresponding physical recuperation devices. Exploiting this vulnerability could potentially allow unauthorized access to manage and read parameters of the recuperation unit "reQnet iZZi".This issue affects "iZZi connect" application versions before 2024010401.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0.
SunGrow iSolarCloud Android application V2.1.6.20241017 and prior contains hardcoded credentials. The application (regardless of the user account) and the cloud uses the same MQTT credentials for exchanging the device telemetry.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account.
An issue was discovered on V-SOL V1600D V2.03.69 OLT devices. The string K0LTdi@gnos312$ is compared to the password provided by the the remote attacker. If it matches, access is provided.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.
Goldshell ASIC Miners v2.1.x was discovered to contain hardcoded credentials which allow attackers to remotely connect via the SSH protocol (port 22).
Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell.
IBM Security Verify Access Appliance 10.0.0 through 10.0.8 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
The Relish (Verve Connect) VH510 device with firmware before 1.0.1.6L0516 contains undocumented default admin credentials for the web management interface. A remote attacker could exploit this vulnerability to login and execute commands on the device, as well as upgrade the firmware image to a malicious version.
Ruckus vRioT through 1.5.1.0.21 has an API backdoor that is hardcoded into validate_token.py. An unauthenticated attacker can interact with the service API by using a backdoor value as the Authorization header.
The JWT library in NATS nats-server before 2.1.9 has Incorrect Access Control because of how expired credentials are handled.
Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism.
Dell RecoverPoint for Virtual Machines 6.0.x contains use of hard-coded credentials vulnerability. A Remote unauthenticated attacker could potentially exploit this vulnerability by gaining access to the source code, easily retrieving these secrets and reusing them to access the system leading to gaining access to unauthorized data.
The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2.
The Telnet service of Rubetek cameras RV-3406, RV-3409, and RV-3411 cameras (firmware versions v342, v339) could allow an remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. The Telnet service cannot be disabled and this password cannot be changed via standard functionality.
In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server.