Credits

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by specifying the value of `userInfo`. When `userInfo` is passed into the `addAuthUser` function and processed by `sscanf` without size validation, it could lead to buffer overflow.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:02 Mar, 2026 | 00:00
Updated At:02 Mar, 2026 | 14:58
Rejected At:
▼CVE Numbering Authority (CNA)

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by specifying the value of `userInfo`. When `userInfo` is passed into the `addAuthUser` function and processed by `sscanf` without size validation, it could lead to buffer overflow.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.tenda.com.cn/material/show/2707
N/A
https://github.com/akuma-QAQ/CVEreport/tree/main/D-link/CVE-2026-24111
N/A
Hyperlink: https://www.tenda.com.cn/material/show/2707
Resource: N/A
Hyperlink: https://github.com/akuma-QAQ/CVEreport/tree/main/D-link/CVE-2026-24111
Resource: N/A
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:02 Mar, 2026 | 15:16
Updated At:03 Mar, 2026 | 15:54

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by specifying the value of `userInfo`. When `userInfo` is passed into the `addAuthUser` function and processed by `sscanf` without size validation, it could lead to buffer overflow.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>w20e_firmware>>15.11.0.6
cpe:2.3:o:tenda:w20e_firmware:15.11.0.6:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>w20e>>4.0
cpe:2.3:h:tenda:w20e:4.0:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-120Primarynvd@nist.gov
CWE ID: CWE-120
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/akuma-QAQ/CVEreport/tree/main/D-link/CVE-2026-24111cve@mitre.org
Exploit
Third Party Advisory
https://www.tenda.com.cn/material/show/2707cve@mitre.org
Product
Hyperlink: https://github.com/akuma-QAQ/CVEreport/tree/main/D-link/CVE-2026-24111
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Hyperlink: https://www.tenda.com.cn/material/show/2707
Source: cve@mitre.org
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

1762Records found

CVE-2024-2853
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.41% / 80.32%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 05:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-28383
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 54.95%
||
7 Day CHG~0.00%
Published-14 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 v1.0 v22.03.01.16 was discovered to contain a stack overflow via the ssid parameter in the sub_431CF0 function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/aax12_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2855
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.07%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 06:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2851
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.41% / 80.32%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 03:00
Updated-22 Aug, 2024 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2807
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.80%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-10 Apr, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-28545
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.36% / 88.80%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18ac18_firmwaren/aac18_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2850
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 58.01%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2856
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.28%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 06:31
Updated-21 Aug, 2024 | 15:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-28553
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.70%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 00:00
Updated-28 Aug, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwaren/aac18_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2806
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.42%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2854
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.53% / 81.13%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 05:31
Updated-12 Aug, 2024 | 18:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 setsambacfg formSetSambaConf os command injection

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18ac18_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2809
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 72.33%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-01 Aug, 2024 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2810
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 67.12%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-12 Aug, 2024 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-38314
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.90%
||
7 Day CHG~0.00%
Published-07 Sep, 2022 | 18:40
Updated-03 Aug, 2024 | 10:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-24436
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-9.2||CRITICAL
EPSS-0.04% / 11.98%
||
7 Day CHG~0.00%
Published-26 Jan, 2026 | 17:40
Updated-28 Jan, 2026 | 19:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Lacks Rate Limiting on Authentication

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2023-2923
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.12% / 31.20%
||
7 Day CHG~0.00%
Published-27 May, 2023 | 07:31
Updated-02 Aug, 2024 | 06:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 fromDhcpListClient stack-based overflow

A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-37800
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 63.83%
||
7 Day CHG~0.00%
Published-25 Aug, 2022 | 14:04
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function fromSetRouteStatic.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac1206_firmwareac1206n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-37175
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 63.83%
||
7 Day CHG~0.00%
Published-19 Aug, 2022 | 20:50
Updated-03 Aug, 2024 | 10:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-44551
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.22% / 44.79%
||
7 Day CHG~0.00%
Published-26 Aug, 2024 | 00:00
Updated-26 Mar, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formGetIptv.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/aax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-3400
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.18%
||
7 Day CHG~0.00%
Published-01 Mar, 2026 | 23:32
Updated-03 Mar, 2026 | 19:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 TextEditingConversion stack-based overflow

A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapsk_crypto2_4g results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-44558
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.79%
||
7 Day CHG~0.00%
Published-26 Aug, 2024 | 00:00
Updated-27 Aug, 2024 | 14:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function setIptvInfo.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/aax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-24107
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.86%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 15:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Failure to validate the value of `usbPartitionName`, which is directly used in `doSystemCmd`, may lead to critical command injection vulnerabilities.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2026-24101
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.29% / 51.86%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 19:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, `s1_1` will be passed into sub_B0488, concatenated into `doSystemCmd`. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-24429
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-9.3||CRITICAL
EPSS-0.11% / 30.04%
||
7 Day CHG+0.01%
Published-26 Jan, 2026 | 17:39
Updated-29 Jan, 2026 | 13:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E V2 Hardcoded Default Password for Built-in Account

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E V2
CWE ID-CWE-1393
Use of Default Password
CVE-2024-44550
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.79%
||
7 Day CHG~0.00%
Published-26 Aug, 2024 | 00:00
Updated-27 Aug, 2024 | 14:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formGetIptv.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/aax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-0581
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.33% / 79.76%
||
7 Day CHG~0.00%
Published-05 Jan, 2026 | 08:02
Updated-23 Feb, 2026 | 08:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 httpd BehaviorManager formBehaviorManager command injection

A vulnerability was determined in Tenda AC1206 15.03.06.23. Affected by this issue is the function formBehaviorManager of the file /goform/BehaviorManager of the component httpd. Executing a manipulation of the argument modulename/option/data/switch can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-30369
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.17% / 38.38%
||
7 Day CHG~0.00%
Published-24 Apr, 2023 | 00:00
Updated-04 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9089
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.23% / 45.29%
||
7 Day CHG~0.00%
Published-16 Aug, 2025 | 23:32
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 SetIpMacBind sub_48E628 stack-based overflow

A vulnerability was determined in Tenda AC20 16.03.08.12. This issue affects the function sub_48E628 of the file /goform/SetIpMacBind. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-9605
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.48% / 64.79%
||
7 Day CHG~0.00%
Published-29 Aug, 2025 | 02:02
Updated-03 Sep, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21/AC23 GetParentControlInfo stack-based overflow

A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac21ac23ac21_firmwareAC21AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-42978
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.49% / 65.32%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-25 Mar, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1206fh1206_firmwaren/afh1206_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9791
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.60%
||
7 Day CHG~0.00%
Published-01 Sep, 2025 | 19:02
Updated-04 Sep, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 fromAdvSetMacMtuWan stack-based overflow

A weakness has been identified in Tenda AC20 16.03.08.05. This vulnerability affects unknown code of the file /goform/fromAdvSetMacMtuWan. This manipulation of the argument wanMTU causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9299
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.48% / 64.90%
||
7 Day CHG~0.00%
Published-21 Aug, 2025 | 12:32
Updated-25 Aug, 2025 | 02:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 getMasterPassengerAnalyseData formGetMasterPassengerAnalyseData stack-based overflow

A vulnerability has been found in Tenda M3 1.0.0.12. Affected by this vulnerability is the function formGetMasterPassengerAnalyseData of the file /goform/getMasterPassengerAnalyseData. The manipulation of the argument Time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-42947
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.52%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-13 Mar, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9088
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.21% / 43.14%
||
7 Day CHG~0.00%
Published-16 Aug, 2025 | 23:02
Updated-21 Aug, 2025 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 formSetVirtualSer save_virtualser_data stack-based overflow

A vulnerability was found in Tenda AC20 16.03.08.12. This vulnerability affects the function save_virtualser_data of the file /goform/formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9090
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.87% / 82.90%
||
7 Day CHG-0.65%
Published-17 Aug, 2025 | 02:02
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 Telnet Service telnet websFormDefine command injection

A vulnerability was identified in Tenda AC20 16.03.08.12. Affected is the function websFormDefine of the file /goform/telnet of the component Telnet Service. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9087
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.23% / 45.29%
||
7 Day CHG~0.00%
Published-16 Aug, 2025 | 22:32
Updated-21 Aug, 2025 | 16:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 SetNetControlList Endpoint set_qosMib_list stack-based overflow

A vulnerability has been found in Tenda AC20 16.03.08.12. This affects the function set_qosMib_list of the file /goform/SetNetControlList of the component SetNetControlList Endpoint. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-42634
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.21% / 86.84%
||
7 Day CHG~0.00%
Published-16 Aug, 2024 | 00:00
Updated-11 Apr, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2025-9748
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.41%
||
7 Day CHG~0.00%
Published-31 Aug, 2025 | 22:02
Updated-04 Sep, 2025 | 16:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 httpd IPSECsave fromIpsecitem stack-based overflow

A vulnerability was determined in Tenda CH22 1.0.0.1. Affected by this issue is the function fromIpsecitem of the file /goform/IPSECsave of the component httpd. Executing manipulation of the argument ipsecno can lead to stack-based buffer overflow. The attack may be performed from remote.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45513
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 36.72%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-24 May, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH451 V1.0.0.9 has a stack overflow vulnerability in the function.P2pListFilter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh451_firmwarefh451n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-9298
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.40% / 60.66%
||
7 Day CHG~0.00%
Published-21 Aug, 2025 | 12:32
Updated-25 Aug, 2025 | 01:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 QuickIndex formQuickIndex stack-based overflow

A flaw has been found in Tenda M3 1.0.0.12. Affected is the function formQuickIndex of the file /goform/QuickIndex. Executing manipulation of the argument PPPOEPassword can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-47119
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.70%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4357
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-7.02% / 91.36%
||
7 Day CHG+5.41%
Published-06 May, 2025 | 13:31
Updated-25 Aug, 2025 | 02:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 telnet command injection

A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-41461
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.49% / 65.20%
||
7 Day CHG~0.00%
Published-24 Jul, 2024 | 00:00
Updated-25 Oct, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-69762
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 54.73%
||
7 Day CHG~0.00%
Published-21 Jan, 2026 | 00:00
Updated-26 Jan, 2026 | 20:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX3 firmware v16.03.12.11 contains a stack overflow in formSetIptv via the list parameter, which can cause memory corruption and enable remote code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax3ax3_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-69766
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 54.73%
||
7 Day CHG~0.00%
Published-21 Jan, 2026 | 00:00
Updated-26 Jan, 2026 | 20:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX3 firmware v16.03.12.11 contains a stack-based buffer overflow in the formGetIptv function due to improper handling of the citytag stack buffer, which may result in memory corruption and remote code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax3ax3_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-26805
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.17% / 38.38%
||
7 Day CHG~0.00%
Published-19 Mar, 2023 | 00:00
Updated-27 Feb, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E v15.11.0.6 (US_W20EV4.0br_v15.11.0.6(1068_1546_841)_CN_TDC) is vulnerable to Buffer Overflow via function formIPMacBindModify.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-69764
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.11% / 29.42%
||
7 Day CHG~0.00%
Published-22 Jan, 2026 | 00:00
Updated-26 Jan, 2026 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX3 firmware v16.03.12.11 contains a stack-based buffer overflow in the formGetIptv function due to improper handling of the stbpvid stack buffer, which may result in memory corruption and remote code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax3ax3_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-69763
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 54.73%
||
7 Day CHG~0.00%
Published-21 Jan, 2026 | 00:00
Updated-26 Jan, 2026 | 20:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX3 firmware v16.03.12.11 contains a stack overflow in formSetIptv via the vlanId parameter, which can cause memory corruption and enable remote code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax3ax3_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-41468
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-81.51% / 99.17%
||
7 Day CHG~0.00%
Published-25 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/afh1201
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-27013
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.21% / 42.60%
||
7 Day CHG~0.00%
Published-07 Apr, 2023 | 00:00
Updated-12 Feb, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10_firmwareac10n/a
CWE ID-CWE-787