Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in userlog-index.php via the `period_preset` parameter.
VMware Workspace one UEM console (2102 prior to 21.2.0.8, 2101 prior to 21.1.0.14, 2011 prior to 20.11.0.27, 2010 prior to 20.10.0.16,2008 prior to 20.8.0.28, 2007 prior to 20.7.0.14,2006 prior to 20.6.0.19, 2005 prior to 20.5.0.46, 2004 prior to 20.4.0.21, 2003 prior to 20.3.0.23, 2001 prior to 20.1.0.32, 1912 prior to 19.12.0.24) contain a cross-site scripting vulnerability. VMware Workspace ONE UEM console does not validate incoming requests during device enrollment after leading to rendering of unsanitized input on the user device in response.
An issue has been discovered in GitLab affecting all versions starting with 13.10. GitLab was vulnerable to a stored XSS in blob viewer of notebooks.
Potential Cross-Site Scripting in ArcSight Logger versions prior to 7.3.0
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
The Giveaways and Contests by RafflePress – Get More Website Traffic, Email Subscribers, and Social Followers plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘parent_url’ parameter in all versions up to, and including, 1.12.5 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
Rocket.Chat before 3.11, 3.10.5, 3.9.7, 3.8.8 is vulnerable to persistent cross-site scripting (XSS) using nested markdown tags allowing a remote attacker to inject arbitrary JavaScript in a message. This flaw leads to arbitrary file read and RCE on Rocket.Chat desktop app.
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability in TE Informatics V5 allows Reflected XSS.This issue affects V5: before 6.2.
A reflected cross-site script vulnerability in GitLab before versions 13.11.6, 13.12.6 and 14.0.2 allowed an attacker to send a malicious link to a victim and trigger actions on their behalf if they clicked it
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Bad validation logic in the Dart SDK versions prior to 2.12.3 allow an attacker to use an XSS attack via DOM clobbering. The validation logic in dart:html for creating DOM nodes from text did not sanitize properly when it came across template tags.
The Responsive Gallery Grid WordPress plugin before 2.3.11 does not sanitise and escape some of its settings, which could allow high privilege users such as admin to perform Stored Cross-Site Scripting attacks even when the unfiltered_html capability is disallowed (for example in multisite setup)
Versions of the package jsondiffpatch before 0.7.6 are vulnerable to Cross-site Scripting (XSS) via the annotated formatter due to improper sanitization of JSON values and property names. If an application compares untrusted JSON/object data and renders annotated formatter output in the DOM, attacker-controlled HTML can be interpreted by the browser, resulting in XSS.
The Archivist – Custom Archive Templates plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the ‘shortcode_attributes' parameter in all versions up to, and including, 1.7.5 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Reflected XSS vulnerability in Micro Focus Application Automation Tools Plugin - Jenkins plugin. The vulnerability affects all version 6.7 and earlier versions.
A vulnerability in Pulse Connect Secure before 9.1R12 could allow a threat actor to perform a cross-site script attack against an authenticated administrator via an unsanitized web parameter.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
The SendPress Newsletters WordPress plugin through 1.23.11.6 does not sanitise and escape some of its settings, which could allow high privilege users such as admin to perform Stored Cross-Site Scripting attacks even when the unfiltered_html capability is disallowed (for example in multisite setup)
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
The WP Google Maps Integration plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the `page` parameter in all versions up to, and including, 1.2. This is due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick an administrator into performing an action such as clicking on a link.
The Forminator plugin for WordPress is vulnerable to Stored Cross-Site Scripting via an uploaded file (e.g. 3gpp file) in all versions up to, and including, 1.29.0 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
Revive Adserver before 5.1.0 is vulnerable to a reflected cross-site scripting (XSS) vulnerability via the publicly accessible afr.php delivery script. While this issue was previously addressed in modern browsers as CVE-2020-8115, some older browsers (e.g., IE10) that do not automatically URL encode parameters were still vulnerable.
A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
A cross-site scripting (XSS) vulnerability at /admin/goods/update in Newbee-Mall v1.0.0 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the goodsName parameter.
Client-Side code injection through Feature Flag name in GitLab CE/EE starting with 11.9 allows a specially crafted feature flag name to PUT requests on behalf of other users via clicking on a link
Possible Improper Neutralization of Input During Web Page Generation Vulnerability in eDirectory has been discovered in OpenTextâ„¢ eDirectory 9.2.3.0000.
Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.11.1 allows stored XSS.
Maccms v10 was discovered to contain a reflected cross-site scripting (XSS) vulnerability in /admin.php/admin/ulog/index.html via the wd parameter.
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface of an affected device. This vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information.
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, 12.1.x before 12.1.5.3, and 11.6.x before 11.6.5.3, undisclosed endpoints in iControl REST allow for a reflected XSS attack, which could lead to a complete compromise of the BIG-IP system if the victim user is granted the admin role. This vulnerability is due to an incomplete fix for CVE-2020-5948. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
In WS_FTP Server versions before 8.8.5, reflected cross-site scripting issues have been identified on various user supplied inputs on the WS_FTP Server administrative interface.
The Blue Triad EZAnalytics plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'bt_webid' parameter in all versions up to, and including, 1.0 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
Multiple Stored Cross-Site Scripting vulnerabilities were discovered in Y Soft SAFEQ 6 Build 53. Multiple fields in the YSoft SafeQ web application can be used to inject malicious inputs that, due to a lack of output sanitization, result in the execution of arbitrary JS code. These fields can be leveraged to perform XSS attacks on legitimate users accessing the SafeQ web interface.
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `status` parameter of campaign-zone-zones.php. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code.
Unauth. Reflected Cross-Site Scripting (XSS) vulnerability in Rocket Apps Open Graphite plugin <=Â 1.6.0 versions.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
The Memberpress plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the ‘message’ and 'error' parameters in all versions up to, and including, 1.11.26 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link. Note - the issue was partially patched in 1.11.25, but could still potentially be exploited under some circumstances.
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in stats.php via the `setPerPage` parameter.
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS.
Cross-site scripting vulnerability exists in WP Statistics versions prior to 13.2.0 because it improperly processes a platform parameter. By exploiting this vulnerability, an arbitrary script may be executed on the web browser of the user who is logging in to the website using the product.
SCBS Online Sports Venue Reservation System v1.0 was discovered to contain a cross-site scripting (XSS) vulnerability via the fid parameter at booking.php.
ACS Commons version 4.9.2 (and earlier) suffers from a Reflected Cross-site Scripting (XSS) vulnerability in version-compare and page-compare due to invalid JCR characters that are not handled correctly. An attacker could potentially exploit this vulnerability to inject malicious JavaScript content into vulnerable form fields and execute it within the context of the victim's browser. Exploitation of this issue requires user interaction in order to be successful.
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS.
In multiple managed switches by WAGO in different versions an attacker may trick a legitimate user to click a link to inject possible malicious code into the Web-Based Management.
AEM's Cloud Service offering, as well as versions 6.5.7.0 (and below), 6.4.8.3 (and below) and 6.3.3.8 (and below) are affected by a stored Cross-Site Scripting (XSS) vulnerability that could be abused by an attacker to inject malicious scripts into vulnerable form fields. Malicious JavaScript may be executed in a victim’s browser when they browse to the page containing the vulnerable field.
Multiple reflected cross-site scripting (xss) vulnerabilities exist in the Web Interface / ssi.cgi functionality of GeoVision LPC2011/LPC2211 1.10. A specially crafted malicious url can lead to an arbitrary javascript code execution. An attacker can provide a crafted URL to trigger this vulnerability. Reflected XXS via the error message for requesting non-existing page.
Jenkins Credentials Plugin 2.3.18 and earlier does not escape user-controlled information on a view it provides, resulting in a reflected cross-site scripting (XSS) vulnerability.
Toast UI Grid is a component to display and edit data. Versions prior to 4.21.3 are vulnerable to cross-site scripting attacks when pasting specially crafted content into editable cells. This issue was fixed in version 4.21.3. There are no known workarounds.