LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
In WhatsUp Gold versions released before 2024.0.2, an unauthenticated attacker can configure LDAP settings.
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to version 1.10.7, FreeSWITCH does not authenticate SIP MESSAGE requests, leading to spam and message spoofing. By default, SIP requests of the type MESSAGE (RFC 3428) are not authenticated in the affected versions of FreeSWITCH. MESSAGE requests are relayed to SIP user agents registered with the FreeSWITCH server without requiring any authentication. Although this behaviour can be changed by setting the `auth-messages` parameter to `true`, it is not the default setting. Abuse of this security issue allows attackers to send SIP MESSAGE messages to any SIP user agent that is registered with the server without requiring authentication. Additionally, since no authentication is required, chat messages can be spoofed to appear to come from trusted entities. Therefore, abuse can lead to spam and enable social engineering, phishing and similar attacks. This issue is patched in version 1.10.7. Maintainers recommend that this SIP message type is authenticated by default so that FreeSWITCH administrators do not need to be explicitly set the `auth-messages` parameter. When following such a recommendation, a new parameter can be introduced to explicitly disable authentication.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has no authentication for /cnr requests.
search-exclude.php in the "Search Exclude" plugin before 1.2.4 for WordPress allows unauthenticated options changes.
Apache Hive before 3.1.3 "CREATE" and "DROP" function operations does not check for necessary authorization of involved entities in the query. It was found that an unauthorized user can manipulate an existing UDF without having the privileges to do so. This allowed unauthorized or underprivileged users to drop and recreate UDFs pointing them to new jars that could be potentially malicious.
A security vulnerability exists in the Zingbox Inspector versions 1.280 and earlier, where authentication is not required when binding the Inspector instance to a different customer tenant.
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
In JetBrains YouTrack before 2025.1.76253 deletion of issues was possible due to missing permission checks in API
The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
Missing authentication when creating and managing the B&R APROL database in versions < R 4.2-07 allows reading and changing the system configuration.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
A remote unauthenticated attacker may be able to bypass authentication by utilizing a specific API route to execute arbitrary OS commands.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to set an arbitrary authentication profile server via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable front panel authentication via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable front panel authentication via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable an authentication profile server via crafted HTTP requests.
On all 7.x and 6.x versions (fixed in 8.0.0), BIG-IQ high availability (HA) when using a Quorum device for automatic failover does not implement any form of authentication with the Corosync daemon. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting information without the access privileges via unspecified vectors.
An issue was discovered on D-Link DSL-2640B E1 EU_1.01 devices. The administrative interface doesn't perform authentication checks for a firmware-update POST request. Any attacker that can access the administrative interface can install firmware of their choice.
An authentication bypass vulnerability has been found in Repox, which allows a remote user to send a specially crafted POST request, due to the lack of any authentication method, resulting in the alteration or creation of users.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
The devices allow access to an unprotected endpoint that allows MPFS file system binary image upload without authentication. The MPFS2 file system module provides a light-weight read-only file system that can be stored in external EEPROM, external serial flash, or internal flash program memory. This file system serves as the basis for the HTTP2 web server module, but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
The web interface on the RIGOL MSO5000 digital oscilloscope with firmware 00.01.03.00.03 allows remote attackers to change the admin password via a zero-length pass0 to the webcontrol changepwd.cgi application, i.e., the entered password only needs to match the first zero characters of the saved password.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application's file system.
An access control issue in Canaan Avalon ASIC Miner 2020.3.30 and below allows unauthenticated attackers to arbitrarily change user passwords via a crafted POST request.
Insecure permissions in cskefu v7.0.1 allows unauthenticated attackers to arbitrarily add administrator accounts.
A vulnerability, which was classified as critical, has been found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. This issue affects the function addCrawlSource of the file novel-crawl/src/main/java/com/java2nb/novel/controller/CrawlController.java. The manipulation leads to missing authentication. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
IBM Guardium Data Encryption (GDE) 3.0.0.2 and 4.0.0.4 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.