Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-4465

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-20 Mar, 2026 | 02:02
Updated At-20 Mar, 2026 | 14:40
Rejected At-
Credits

D-Link DIR-513 formSysCmd os command injection

A flaw has been found in D-Link DIR-513 1.10. The impacted element is an unknown function of the file /goform/formSysCmd. Executing a manipulation of the argument sysCmd can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:20 Mar, 2026 | 02:02
Updated At:20 Mar, 2026 | 14:40
Rejected At:
â–¼CVE Numbering Authority (CNA)
D-Link DIR-513 formSysCmd os command injection

A flaw has been found in D-Link DIR-513 1.10. The impacted element is an unknown function of the file /goform/formSysCmd. Executing a manipulation of the argument sysCmd can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Affected Products
Vendor
D-Link CorporationD-Link
Product
DIR-513
Versions
Affected
  • 1.10
Problem Types
TypeCWE IDDescription
CWECWE-78OS Command Injection
CWECWE-77Command Injection
Type: CWE
CWE ID: CWE-78
Description: OS Command Injection
Type: CWE
CWE ID: CWE-77
Description: Command Injection
Metrics
VersionBase scoreBase severityVector
4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
3.06.3MEDIUM
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
2.06.5N/A
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 2.0
Base score: 6.5
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
AttackingLin (VulDB User)
Timeline
EventDate
Advisory disclosed2026-03-19 00:00:00
VulDB entry created2026-03-19 01:00:00
VulDB entry last update2026-03-19 21:34:01
Event: Advisory disclosed
Date: 2026-03-19 00:00:00
Event: VulDB entry created
Date: 2026-03-19 01:00:00
Event: VulDB entry last update
Date: 2026-03-19 21:34:01
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.351755
vdb-entry
technical-description
https://vuldb.com/?ctiid.351755
signature
permissions-required
https://vuldb.com/?submit.772866
third-party-advisory
https://github.com/InfiniteLin/Lin-s-CVEdb/blob/main/DIR-513/formSysCmd.pdf
exploit
https://www.dlink.com/
product
Hyperlink: https://vuldb.com/?id.351755
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.351755
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.772866
Resource:
third-party-advisory
Hyperlink: https://github.com/InfiniteLin/Lin-s-CVEdb/blob/main/DIR-513/formSysCmd.pdf
Resource:
exploit
Hyperlink: https://www.dlink.com/
Resource:
product
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:20 Mar, 2026 | 02:16
Updated At:03 Apr, 2026 | 19:37

A flaw has been found in D-Link DIR-513 1.10. The impacted element is an unknown function of the file /goform/formSysCmd. Executing a manipulation of the argument sysCmd can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Secondary
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

D-Link Corporation
dlink
>>dir-513_firmware>>1.10
cpe:2.3:o:dlink:dir-513_firmware:1.10:*:*:*:*:*:*:*
D-Link Corporation
dlink
>>dir-513>>a1
cpe:2.3:h:dlink:dir-513:a1:*:*:*:*:*:*:*
D-Link Corporation
dlink
>>dir-513>>a2
cpe:2.3:h:dlink:dir-513:a2:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarycna@vuldb.com
CWE-78Primarycna@vuldb.com
CWE-78Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-78
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/InfiniteLin/Lin-s-CVEdb/blob/main/DIR-513/formSysCmd.pdfcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.351755cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.351755cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.772866cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.dlink.com/cna@vuldb.com
Product
Hyperlink: https://github.com/InfiniteLin/Lin-s-CVEdb/blob/main/DIR-513/formSysCmd.pdf
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.351755
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.351755
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.772866
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.dlink.com/
Source: cna@vuldb.com
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

2484Records found

CVE-2025-8956
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.21% / 43.69%
||
7 Day CHG+0.02%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-9377
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-76.64% / 98.95%
||
7 Day CHG~0.00%
Published-09 Jul, 2020 | 12:06
Updated-10 Nov, 2025 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-04-15||The impacted product is end-of-life and should be disconnected if still in use.

D-Link DIR-610 devices allow Remote Command Execution via the cmd parameter to command.php. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-610_firmwaredir-610n/aDIR-610 Devices
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7836
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.36% / 58.07%
||
7 Day CHG+0.04%
Published-19 Jul, 2025 | 16:44
Updated-03 Oct, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-816L Environment Variable cgibin lxmldbc_system command injection

A vulnerability has been found in D-Link DIR-816L up to 2.06B01 and classified as critical. Affected by this vulnerability is the function lxmldbc_system of the file /htdocs/cgibin of the component Environment Variable Handler. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-816l_firmwaredir-816lDIR-816L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7932
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.36% / 58.07%
||
7 Day CHG+0.04%
Published-21 Jul, 2025 | 17:02
Updated-03 Oct, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑817L ssdpcgi lxmldbc_system command injection

A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-817ldir-817l_firmwareDIR‑817L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7192
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.33% / 55.94%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 19:32
Updated-14 Jul, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-645 ssdpcgi cgibin ssdpcgi_main command injection

A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-645_firmwaredir-645DIR-645
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6898
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.32% / 54.72%
||
7 Day CHG+0.08%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6899
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.46% / 64.33%
||
7 Day CHG+0.12%
Published-30 Jun, 2025 | 08:32
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+/DI-8200G msp_info.htm os command injection

A vulnerability, which was classified as critical, was found in D-Link DI-7300G+ and DI-8200G 17.12.20A1/19.12.25A1. This affects an unknown part of the file msp_info.htm. The manipulation of the argument flag/cmd/iface leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-8200gdi-8200g_firmwaredi-7300g\+DI-8200GDI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6896
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.45% / 63.52%
||
7 Day CHG+0.12%
Published-30 Jun, 2025 | 07:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ wget_test.asp os command injection

A vulnerability classified as critical has been found in D-Link DI-7300G+ 19.12.25A1. Affected is an unknown function of the file wget_test.asp. The manipulation of the argument url leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-6765
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-0.79% / 73.88%
||
7 Day CHG~0.00%
Published-10 Apr, 2020 | 18:26
Updated-04 Aug, 2024 | 09:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DSL-GS225 J1 AU_1.0.4 devices allow an admin to execute OS commands by placing shell metacharacters after a supported CLI command, as demonstrated by ping -c1 127.0.0.1; cat/etc/passwd. The CLI is reachable by TELNET.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-gs225dsl-gs225_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5571
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.59% / 87.77%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5492
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.75% / 73.26%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5573
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.23% / 88.79%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-44835
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-6.38% / 91.04%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-28 May, 2025 | 16:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-816 A2V1.1.0B05 was found to contain a command injection in iptablesWebsFilterRun, which allows remote attackers to execute arbitrary commands via shell.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-816_a2dir-816_a2_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4445
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.53%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L wake_on_lan command injection

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-44342
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.29% / 79.64%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 00:00
Updated-30 Aug, 2024 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the wl(0).(0)_ssid parameter. This vulnerability is exploited via a crafted POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846w_firmwaredir-846wn/adir-846w_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44340
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.17% / 78.72%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 00:00
Updated-30 Aug, 2024 | 14:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via keys smartqos_express_devices and smartqos_normal_devices in SetSmartQoSSettings.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846w_firmwaredir-846wn/adir-846w_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-25759
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.45% / 80.83%
||
7 Day CHG~0.00%
Published-15 Dec, 2020 | 19:28
Updated-04 Aug, 2024 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DSR-250 3.17 devices. Certain functionality in the Unified Services Router web interface could allow an authenticated attacker to execute arbitrary commands, due to a lack of validation of inputs provided in multipart HTTP POST requests.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsr-500_firmwaredsr-1000_firmwaredsr-500dsr-500n_firmwaredsr-150dsr-250ndsr-150ndsr-250n_firmwaredsr-1000n_firmwaredsr-250dsr-150n_firmwaredsr-500acdsr-1000ac_firmwaredsr-150_firmwaredsr-1000dsr-1000acdsr-500ac_firmwaredsr-500ndsr-250_firmwaredsr-1000nn/a
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-39202
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-7.6||HIGH
EPSS-2.28% / 84.69%
||
7 Day CHG~0.00%
Published-08 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-823X firmware - 240126 was discovered to contain a remote command execution (RCE) vulnerability via the dhcpd_startip parameter at /goform/set_lan_settings.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823x_ax3000_firmwaredir-823x_ax3000n/adir-823x_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4454
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.53%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L wake_on_lan command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been declared as critical. This vulnerability affects the function wake_on_lan. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4453
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.53%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSysCmd command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4443
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.74% / 82.56%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 23:31
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L sub_454F2C command injection

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4340
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.78% / 86.08%
||
7 Day CHG+0.33%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-44341
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.81% / 88.11%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 00:00
Updated-30 Aug, 2024 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the lan(0)_dhcps_staticlist parameter. This vulnerability is exploited via a crafted POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846w_firmwaredir-846wn/adir-846w_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10215
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.07% / 86.77%
||
7 Day CHG~0.00%
Published-07 Mar, 2020 | 00:30
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the dns_query_name parameter in a dns_query.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.

Action-Not Available
Vendor-n/aTRENDnet, Inc.D-Link Corporation
Product-tew-632brpdir-825_firmwaredir-825tew-632brp_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10216
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.43% / 87.49%
||
7 Day CHG~0.00%
Published-07 Mar, 2020 | 00:29
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the date parameter in a system_time.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.

Action-Not Available
Vendor-n/aTRENDnet, Inc.D-Link Corporation
Product-tew-632brpdir-825_firmwaredir-825tew-632brp_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10213
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.41% / 87.45%
||
7 Day CHG~0.00%
Published-07 Mar, 2020 | 00:29
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the wps_sta_enrollee_pin parameter in a set_sta_enrollee_pin.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.

Action-Not Available
Vendor-n/aTRENDnet, Inc.D-Link Corporation
Product-tew-632brpdir-825_firmwaredir-825tew-632brp_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8319
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 81.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 23:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the system function with untrusted input from the request body for the SetStaticRouteIPv4Settings API function, as demonstrated by shell metacharacters in the Gateway field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8318
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 81.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the twsystem function with untrusted input from the request body for the SetSysEmailSettings API function, as demonstrated by shell metacharacters in the SMTPServerPort field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8314
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 81.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 20:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the system function with untrusted input from the request body for the SetQoSSettings API function, as demonstrated by shell metacharacters in the IPAddress field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8315
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 81.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-17 Sep, 2024 | 03:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the twsystem function with untrusted input from the request body for the SetIPv4FirewallSettings API function, as demonstrated by shell metacharacters in the SrcIPv4AddressRangeStart field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8313
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 81.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 23:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the twsystem function with untrusted input from the request body for the SetIPv6FirewallSettings API function, as demonstrated by shell metacharacters in the SrcIPv6AddressRangeStart field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8312
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 81.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-17 Sep, 2024 | 03:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the twsystem function with untrusted input from the request body for the SetSysLogSettings API function, as demonstrated by shell metacharacters in the IPAddress field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4346
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.53%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 10:00
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formSetWAN_Wizard534 buffer overflow

A vulnerability was found in D-Link DIR-600L up to 2.07B01. It has been classified as critical. Affected is the function formSetWAN_Wizard534. The manipulation of the argument host leads to buffer overflow. It is possible to launch the attack remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-11960
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.08% / 86.79%
||
7 Day CHG+0.79%
Published-28 Nov, 2024 | 14:31
Updated-04 Dec, 2024 | 16:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetPortTr buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been declared as critical. This vulnerability affects the function formSetPortTr of the file /goform/formSetPortTr. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-11959
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.08% / 86.79%
||
7 Day CHG+0.79%
Published-28 Nov, 2024 | 14:31
Updated-04 Dec, 2024 | 16:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formResetStatistic buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been classified as critical. This affects the function formResetStatistic of the file /goform/formResetStatistic. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4347
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.53%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 10:31
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formWlSiteSurvey buffer overflow

A vulnerability was found in D-Link DIR-600L up to 2.07B01. It has been declared as critical. Affected by this vulnerability is the function formWlSiteSurvey. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4355
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.42% / 80.64%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 12:31
Updated-13 May, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda DAP-1520 api set_ws_action heap-based overflow

A vulnerability was found in Tenda DAP-1520 1.10B04_BETA02. It has been classified as critical. This affects the function set_ws_action of the file /dws/api/. The manipulation leads to heap-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.D-Link Corporation
Product-dap-1520_firmwaredap-1520DAP-1520
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4342
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.94% / 76.22%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:31
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formEasySetupWizard3 buffer overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-600L up to 2.07B01. Affected by this issue is the function formEasySetupWizard3. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-600ldir-600l_firmwareDIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4348
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.53%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 11:00
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formSetWanL2TP buffer overflow

A vulnerability was found in D-Link DIR-600L up to 2.07B01. It has been rated as critical. Affected by this issue is the function formSetWanL2TP. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-11047
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 36.22%
||
7 Day CHG~0.00%
Published-10 Nov, 2024 | 03:31
Updated-13 Nov, 2024 | 20:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow

A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8003_firmwaredi-8003DI-8003di-8003_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11048
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 36.22%
||
7 Day CHG~0.00%
Published-10 Nov, 2024 | 04:00
Updated-13 Nov, 2024 | 20:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow

A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8003_firmwaredi-8003DI-8003di-8003_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-5214
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.03% / 9.44%
||
7 Day CHG~0.00%
Published-31 Mar, 2026 | 21:15
Updated-02 Apr, 2026 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 account_mgr.cgi cgi_addgroup_get_group_quota_minsize stack-based overflow

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20260205. Impacted is the function cgi_addgroup_get_group_quota_minsize of the file /cgi-bin/account_mgr.cgi. The manipulation of the argument Name results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been made public and could be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-320lwdns-322l_firmwaredns-1100-4_firmwaredns-345dnr-326_firmwaredns-327ldns-326_firmwarednr-326dns-327l_firmwaredns-321_firmwaredns-322ldns-320_firmwaredns-120dns-321dns-343dns-315l_firmwaredns-315ldns-340ldnr-202ldns-320lw_firmwaredns-325_firmwaredns-1550-04_firmwaredns-120_firmwaredns-320ldns-1200-05dns-726-4_firmwaredns-1200-05_firmwaredns-726-4dns-320l_firmwaredns-1550-04dns-325dns-323_firmwaredns-343_firmwaredns-340l_firmwaredns-323dns-326dnr-202l_firmwaredns-345_firmwaredns-320dns-1100-4DNS-321DNS-323DNS-1550-04DNS-1100-4DNS-327LDNR-202LDNS-320LWDNR-322LDNS-345DNS-320DNS-1200-05DNS-340LDNS-320LDNS-326DNR-326DNS-315LDNS-726-4DNS-325DNS-120DNS-343
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-5212
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.97%
||
7 Day CHG~0.00%
Published-31 Mar, 2026 | 20:15
Updated-03 Apr, 2026 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 webdav_mgr.cgi Webdav_Upload_File stack-based overflow

A vulnerability has been found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20260205. This issue affects the function Webdav_Upload_File of the file /cgi-bin/webdav_mgr.cgi. The manipulation of the argument f_file leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-320lwdns-322l_firmwaredns-1100-4_firmwaredns-345dnr-326_firmwaredns-327ldns-326_firmwarednr-326dns-327l_firmwaredns-321_firmwaredns-322ldns-320_firmwaredns-120dns-321dns-343dns-315l_firmwaredns-315ldns-340ldnr-202ldns-320lw_firmwaredns-325_firmwaredns-1550-04_firmwaredns-120_firmwaredns-320ldns-1200-05dns-726-4_firmwaredns-1200-05_firmwaredns-726-4dns-320l_firmwaredns-1550-04dns-325dns-323_firmwaredns-343_firmwaredns-340l_firmwaredns-323dns-326dnr-202l_firmwaredns-345_firmwaredns-320dns-1100-4DNS-321DNS-323DNS-1550-04DNS-1100-4DNS-327LDNR-202LDNS-320LWDNR-322LDNS-345DNS-320DNS-1200-05DNS-340LDNS-320LDNS-326DNR-326DNS-315LDNS-726-4DNS-325DNS-120DNS-343
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-5322
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.48% / 64.92%
||
7 Day CHG~0.00%
Published-01 Oct, 2023 | 04:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 edit_manageadmin.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. Affected by this issue is some unknown functionality of the file /sysmanage/edit_manageadmin.php. The manipulation of the argument id leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240992. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-5151
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-20.38% / 95.55%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:31
Updated-24 Sep, 2024 | 19:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 autheditpwd.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-8000 up to 20151231. Affected by this vulnerability is an unknown functionality of the file /autheditpwd.php. The manipulation of the argument hid_id leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240247. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-8000DAR-8000dar-8000_firmware
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-5148
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.78% / 89.48%
||
7 Day CHG+0.30%
Published-25 Sep, 2023 | 01:00
Updated-24 Sep, 2024 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 uploadfile.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231. It has been declared as critical. This vulnerability affects unknown code of the file /Tool/uploadfile.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240244. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000dar-8000_firmwaredar-7000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5149
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.59% / 69.19%
||
7 Day CHG+0.04%
Published-25 Sep, 2023 | 01:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 userattestation.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5153
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.43% / 62.27%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 02:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 querysql.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-8000 up to 20151231. This affects an unknown part of the file /Tool/querysql.php. The manipulation leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240249 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-8000
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-5154
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-79.97% / 99.11%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 03:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 changelogo.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-8000 up to 20151231 and classified as critical. This vulnerability affects unknown code of the file /sysmanage/changelogo.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-240250 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-8000DAR-8000dar-8000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5146
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.33% / 84.85%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 00:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 updatelib.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231 and classified as critical. Affected by this issue is some unknown functionality of the file /sysmanage/updatelib.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-240242 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type