An issue discovered in Shenzhen Zhiboton Electronics ZBT WE1626 Router v 21.06.18 allows attackers to escalate privileges via WGET command to the Network Diagnosis endpoint.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
The installer in SIGB PMB before and fixed in v.8.0.1.2 allows remote code execution.
An issue was discovered on Libre Wireless LS9 LS1.5/p7040 devices. There is a Authentication Bypass in the Web Interface. This interface does not properly restrict access to internal functionality. Despite presenting a password login page on first access, authentication is not required to access privileged functionality. As such, it's possible to directly access APIs that should not be exposed to an unauthenticated user.
PC Keyboard allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
Telepad allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Orca HCM from LEARNING DIGITAL has an Missing Authentication vulnerability, allowing unauthenticated remote attacker to exploit this functionality to create an account with administrator privilege and subsequently use it to log in.
The WooCommerce Photo Reviews Premium plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 1.3.13.2. This is due to the plugin not properly validating what user transient is being used in the login() function and not properly verifying the user's identity. This makes it possible for unauthenticated attackers to log in as user that has dismissed an admin notice in the past 30 days, which is often an administrator. Alternatively, a user can log in as any user with any transient that has a valid user_id as the value, though it would be more difficult to exploit this successfully.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system.
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
The Jupiter X Core plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 4.7.5. This is due to improper authentication via the Social Login widget. This makes it possible for unauthenticated attackers to log in as the first user to have logged in with a social media account, including administrator accounts. Attackers can exploit the vulnerability even if the Social Login element has been disabled, as long as it was previously enabled and used. The vulnerability was partially patched in version 4.7.5, and fully patched in version 4.7.8.
The product exposes a service that is intended for local only to all network interfaces without any authentication.
The WooCommerce - Social Login plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.7.5. This is due to the use of loose comparison of the activation code in the 'woo_slg_confirm_email_user' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the userID. This requires the email module to be enabled.
A file write vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
An issue was discovered in BACKCLICK Professional 5.9.63. User authentication for accessing the CORBA back-end services can be bypassed.
An issue was discovered in ONAP HOLMES before Dublin. By accessing port 9202 of dep-holmes-engine-mgmt pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to an exposed internal communications interface, it is possible to execute arbitrary system commands on the server.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).
A vulnerability has been identified in TeleControl Server Basic V3.1 (All versions >= V3.1.2.2 < V3.1.2.3). The affected application contains an information disclosure vulnerability. This could allow an unauthenticated remote attacker to obtain password hashes of users and to login to and perform authenticated operations of the database service.
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to exposed CORBA management services, arbitrary system commands can be executed on the server.
Missing Authentication for Critical Function vulnerability in Profelis Informatics and Consulting PassBox allows Authentication Abuse.This issue affects PassBox: before v1.2.
register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services.
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
OMNTEC Proteus Tank Monitoring OEL8000III Series could allow an attacker to perform administrative actions without proper authentication.
A vulnerability, which was classified as critical, was found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. Affected is the function genCode of the file novel-admin/src/main/java/com/java2nb/common/controller/GeneratorController.java. The manipulation leads to missing authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An unauthenticated remote attacker can manipulate the device via Telnet, stop processes, read, delete and change data.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Positron Broadcast Signal Processor TRA7005 v1.20 is vulnerable to an authentication bypass exploit that could allow an attacker to have unauthorized access to protected areas of the application.
A vulnerability classified as critical was found in SourceCodester Book Store Management System 1.0. This vulnerability affects unknown code of the file /bsms_ci/index.php. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214588.
The Goobi viewer is a web application that allows digitised material to be displayed in a web browser. From 4.8.0 to before 26.04.1, the Goobi viewer REST endpoint POST /api/v1/index/stream accepted an arbitrary Solr streaming expression from unauthenticated network clients and forwarded it to the backend Solr server without restriction. An attacker could read the complete Solr index and, in default Solr deployments, also modify or delete indexed records. This vulnerability is fixed in 26.04.1.
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Missing authentication for a critical function in Palo Alto Networks Expedition can lead to an Expedition admin account takeover for attackers with network access to Expedition. Note: Expedition is a tool aiding in configuration migration, tuning, and enrichment. Configuration secrets, credentials, and other data imported into Expedition is at risk due to this issue.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
Multiple W&T products of the ComServer Series are prone to an authentication bypass. An unathenticated remote attacker, can log in without knowledge of the password by crafting a modified HTTP GET Request.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (VA deployments only) expose a set of unauthenticated REST API endpoints that return configuration files and clear‑text passwords. The same endpoints also disclose the Laravel APP_KEY used for cryptographic signing. Because the APP_KEY is required to generate valid signed requests, an attacker who obtains it can craft malicious payloads that are accepted by the application and achieve remote code execution on the appliance. This vulnerability has been identified by the vendor as: V-2024-018 — RCE & Leaks via API.
The Quantenna Wi-Fi chips ship with an unauthenticated telnet interface by default. This is an instance of CWE-306, "Missing Authentication for Critical Function," and is estimated as a CVSS 9.1 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N). This issue affects Quantenna Wi-Fi chipset through version 8.0.0.28 of the latest SDK, and appears to be unpatched at the time of this CVE record's first publishing, though the vendor has released a best practices guide for implementors of this chipset.
An authentication bypass vulnerability exists in GFI Kerio Control 9.4.5 due to insecure default proxy configuration and weak access control in the GFIAgent service. The non-transparent proxy on TCP port 3128 can be used to forward unauthenticated requests to internal services such as GFIAgent, bypassing firewall restrictions and exposing internal management endpoints. This enables unauthenticated attackers to access the GFIAgent service on ports 7995 and 7996, retrieve the appliance UUID, and issue administrative requests via the proxy. Exploitation results in full administrative access to the Kerio Control appliance.
An unauthenticated arbitrary file upload vulnerability exists in Tiki Wiki CMS Groupware version 15.1 and earlier via the ELFinder component's default connector (connector.minimal.php), which allows remote attackers to upload and execute malicious PHP scripts in the context of the web server. The vulnerable component does not enforce file type validation, allowing attackers to craft a POST request to upload executable PHP payloads through the ELFinder interface exposed at /vendor_extra/elfinder/.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (only VA deployments) expose an unauthenticated firmware-upload flow: a public page returns a signed token usable at va-api/v1/update, and every Docker image contains the appliance’s private GPG key and hard-coded passphrase. An attacker who extracts the key and obtains a token can decrypt, modify, re-sign, upload, and trigger malicious firmware, gaining remote code execution. This vulnerability has been identified by the vendor as: V-2024-020 — Remote Code Execution.
Nginx UI is a web user interface for the Nginx web server. From version 2.0.0 to before version 2.3.8, an unauthenticated network attacker can claim the initial administrator account on a fresh nginx-ui instance during the first-run setup window. The public /api/install endpoint is reachable without authentication, and the request-encryption flow only protects payload confidentiality in transit; it does not authenticate who is allowed to perform installation. A remote attacker who reaches the service before the legitimate operator can set the admin email, username, and password, causing permanent initial-instance takeover. This issue has been patched in version 2.3.8.
BSS Continuity CMS 4.2.22640.0 has an Authentication Bypass vulnerability
An issue was discovered in genua genugate before 9.0 Z p19, 9.1.x through 9.6.x before 9.6 p7, and 10.x before 10.1 p4. The Web Interfaces (Admin, Userweb, Sidechannel) can use different methods to perform the authentication of a user. A specific authentication method during login does not check the provided data (when a certain manipulation occurs) and returns OK for any authentication request. This allows an attacker to login to the admin panel as a user of his choice, e.g., the root user (with highest privileges) or even a non-existing user.
Langflow versions prior to 1.3.0 are susceptible to code injection in the /api/v1/validate/code endpoint. A remote and unauthenticated attacker can send crafted HTTP requests to execute arbitrary code.
A request-validation issue was discovered in Open5GS 2.1.3 through 2.2.x before 2.2.1. The WebUI component allows an unauthenticated user to use a crafted HTTP API request to create, read, update, or delete entries in the subscriber database. For example, new administrative users can be added. The issue occurs because Express is not set up to require authentication.
CrowdStrike has released security updates to address a critical unauthenticated path traversal vulnerability (CVE-2026-40050) in LogScale. This vulnerability only requires mitigation by customers that host specific versions of LogScale and does not affect Next-Gen SIEM customers. The vulnerability exists in a specific cluster API endpoint that, if exposed, allows a remote attacker to read arbitrary files from the server filesystem without authentication. Next-Gen SIEM customers are not affected and do not need to take any action. CrowdStrike mitigated the vulnerability for LogScale SaaS customers by deploying network-layer blocks to all clusters on April 7, 2026. We have proactively reviewed all log data and there is no evidence of exploitation. LogScale Self-hosted customers should upgrade to a patched version immediately to remediate the vulnerability. CrowdStrike identified this vulnerability during continuous and ongoing product testing.
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.