CVE-2026-1690
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.85% / 74.48%
||
7 Day CHG+0.35%
Published-30 Jan, 2026 | 16:32
Updated-10 Feb, 2026 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG10 formSysCmd system command injection

A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg10hg10_firmwareHG10
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1689
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-4.33% / 88.66%
||
7 Day CHG+1.94%
Published-30 Jan, 2026 | 16:32
Updated-10 Feb, 2026 | 14:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG10 Login formLogin checkUserFromLanOrWan command injection

A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg10hg10_firmwareHG10
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1687
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-5.03% / 89.50%
||
7 Day CHG+2.65%
Published-30 Jan, 2026 | 16:02
Updated-10 Feb, 2026 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG10 Boa Webserver formSamba command injection

A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg10hg10_firmwareHG10
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')