CVE-2019-10953
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.48% / 65.63%
||
7 Day CHG+0.04%
Published-17 Apr, 2019 | 14:02
Updated-04 Jun, 2026 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.

Action-Not Available
Vendor-wagoWAGOSiemens AGSchneider Electric SEABBPhoenix Contact GmbH & Co. KG
Product-pfc100modicon_m2216es7211-1ae40-0xb0bacnet\/ip6ed1052-1cc01-0ba8_firmware6es7211-1ae40-0xb0_firmwarepm554-tp-eth_firmwareethernet6es7314-6eh04-0ab0_firmware6es7314-6eh04-0ab0knx_ipmodicon_m221_firmwareilc_151_ethknx_ip_firmwarebacnet\/ip_firmware6ed1052-1cc01-0ba8pfc100_firmwareethernet_firmwareilc_151_eth_firmwarepm554-tp-eth6ES7211-1AE40-0XB0 Simatic S7-1211750-8100 Controller PFC100ILC 191 ETH 2TX750-889 Controller KNX IP2700974 ILC 151 ETH750-880 Controller ETH6ED1052-1CC01-0BA8 Logo! 8750-831 Controller BACnet/IPModicon M221EcoStruxure Machine Expert – Basic6ES7314-6EH04-0AB0 Simatic S7-3141SAP120600R0071 PM554-TP-ETH
CWE ID-CWE-400
Uncontrolled Resource Consumption
CWE ID-CWE-770
Allocation of Resources Without Limits or Throttling
CVE-2017-6030
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.53% / 67.53%
||
7 Day CHG+0.13%
Published-30 Jun, 2017 | 02:35
Updated-04 Jun, 2026 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric Modicon PLCs Predictable Value Range from Previous Values

A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.

Action-Not Available
Vendor-Schneider Electric SE
Product-modicon_m221_firmwaremodicon_m221modicon_m241modicon_m251modicon_m251_firmwaremodicon_m241_firmwareModicon M241Modicon M251Modicon M221
CWE ID-CWE-343
Predictable Value Range from Previous Values
CWE ID-CWE-331