Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools

TN-4500A Series

Source -

CNA

CNA CVEs -

3

ADP CVEs -

0

CISA CVEs -

0

NVD CVEs -

0
Related CVEsRelated VendorsRelated AssignersReports
3Vulnerabilities found

CVE-2025-1680
Assigner-Moxa Inc.
ShareView Details
Assigner-Moxa Inc.
CVSS Score-Not Assigned
EPSS-0.04% / 10.49%
||
7 Day CHG~0.00%
Published-23 Oct, 2025 | 13:56
Updated-27 Oct, 2025 | 13:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An acceptance of extraneous untrusted data with trusted data vulnerability has been identified in Moxa’s Ethernet switches, which allows attackers with administrative privileges to manipulate HTTP Host headers by injecting a specially crafted Host header into HTTP requests sent to an affected device’s web service. This vulnerability is classified as Host Header Injection, where invalid Host headers can manipulate to redirect users, forge links, or phishing attacks. There is no impact to the confidentiality, integrity, and availability of the affected device; no loss of confidentiality, integrity, and availability within any subsequent systems.

Action-Not Available
Vendor-Moxa Inc.
Product-TN-G6500 SeriesTN-4500A SeriesTN-5500A SeriesTN-G4500 Series
CWE ID-CWE-349
Acceptance of Extraneous Untrusted Data With Trusted Data
CVE-2025-1679
Assigner-Moxa Inc.
ShareView Details
Assigner-Moxa Inc.
CVSS Score-4.8||MEDIUM
EPSS-0.08% / 24.32%
||
7 Day CHG~0.00%
Published-23 Oct, 2025 | 13:51
Updated-27 Oct, 2025 | 13:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site Scripting has been identified in Moxa’s Ethernet switches, which allows an authenticated administrative attacker to inject malicious scripts to an affected device’s web service that could impact authenticated users interacting with the device’s web interface. This vulnerability is classified as stored cross-site scripting (XSS); attackers inject malicious scripts into the system, and the scripts persist across sessions. There is no impact to the confidentiality, integrity, and availability of the affected device; no loss of availability within any subsequent systems but has some loss of confidentiality and integrity within the subsequent system.

Action-Not Available
Vendor-Moxa Inc.
Product-TN-G6500 SeriesTN-4500A SeriesTN-5500A SeriesTN-G4500 Series
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-9137
Assigner-Moxa Inc.
ShareView Details
Assigner-Moxa Inc.
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.48%
||
7 Day CHG~0.00%
Published-14 Oct, 2024 | 08:09
Updated-19 Sep, 2025 | 08:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Moxa Service Missing Authentication for Critical Function

The affected product lacks an authentication check when sending commands to the server via the Moxa service. This vulnerability allows an attacker to execute specified commands, potentially leading to unauthorized downloads or uploads of configuration files and system compromise.

Action-Not Available
Vendor-Moxa Inc.
Product-OnCell G4302-LTE4 SeriesEDS-P506E SeriesEDS-510A SeriesEDS-P510 SeriesEDS-608 SeriesICS-G7852A SeriesNAT-102 SeriesSDS-3006 SeriesICS-G7848A SeriesEDS-616 SeriesEDR-8010 SeriesEDS-611 SeriesSDS-3010 SeriesEDS-P510A SeriesEDR-G9010 SeriesTN-4900 SeriesIKS-6728A SeriesICS-G7826A SeriesICS-G7752A SeriesEDS-508A SeriesICS-G7750A SeriesICS-G7850A SeriesICS-G7748A SeriesEDS-528E SeriesPT-7728 SeriesPT-G7828 SeriesIKS-G6824A SeriesTN-G6500 SeriesSDS-G3006 SeriesEDF-G1002-BP SeriesEDS-G516E SeriesEDS-516A SeriesICS-G7528A SeriesSDS-G3008 SeriesPT-7828 SeriesEDS-408A SeriesEDS-G509 SeriesEDR-G9004 SeriesPT-G7728 SeriesEDS-510E SeriesPT-G510 SeriesICS-G7526A SeriesEDS-405A SeriesSDS-3008 SeriesSDS-G3010 SeriesTN-G4500 SeriesEDS-619 SeriesPT-G503 SeriesSDS-3016 SeriesIKS-6726A SeriesEDS-G512E SeriesSDS-G3016 SeriesEDS-505A SeriesEDS-518A SeriesEDS-518E SeriesIKS-G6524A SeriesTN-5500A SeriesEDS-G508E SeriesTN-4500A SeriesICS-G7828A Seriesedr-g9010tn-4900edr-g9004nat-102edf-g1002-bpedr-8010oncell_g4302-lte4
CWE ID-CWE-306
Missing Authentication for Critical Function