helpflash_iot_firmware

Source -

NVD

CNA CVEs -

0

ADP CVEs -

0

CISA CVEs -

0

NVD CVEs -

1
Related CVEsRelated VendorsRelated AssignersReports
1Vulnerabilities found

CVE-2025-65855
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-6.6||MEDIUM
EPSS-0.01% / 0.19%
||
7 Day CHG~0.00%
Published-17 Dec, 2025 | 00:00
Updated-06 Jan, 2026 | 15:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The OTA firmware update mechanism in Netun Solutions HelpFlash IoT (firmware v18_178_221102_ASCII_PRO_1R5_50) uses hard-coded WiFi credentials identical across all devices and does not authenticate update servers or validate firmware signatures. An attacker with brief physical access can activate OTA mode (8-second button press), create a malicious WiFi AP using the known credentials, and serve malicious firmware via unauthenticated HTTP to achieve arbitrary code execution on this safety-critical emergency signaling device.

Action-Not Available
Vendor-netunn/a
Product-helpflash_iothelpflash_iot_firmwaren/a
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CWE ID-CWE-494
Download of Code Without Integrity Check
CWE ID-CWE-798
Use of Hard-coded Credentials